APC UPS

The JSA DSM for APC UPS accepts syslog events from the APC Smart-Uninterruptible Power Supply (UPS) family of products.

Note:

Events from RC-Series Smart-UPS are not supported.

The following table identifies the specifications for the APC UPS DSM:

Table 1: APC UPS DSM Specifications

Specification

Value

Manufacturer

APC

DSM name

APC UPS

RPM file name

DSM-APCUPS-JSA_version-build_number.noarch.rpm

Protocol

Syslog

Recorded event types

UPS events

Battery events

Bypass events

Communication events

Input power events

Low battery condition events

SmartBoost events

SmartTrim events

Automatically discovered?

No

Includes identity?

No

Includes custom properties?

No

More information

APC website

To send APC UPS events to JSA, complete the following steps:

  1. If automatic updates are not enabled, download and install the most recent version of the APC UPS DSM RPM from the https://support.juniper.net/support/downloads/ onto your JSA console.

  2. Create an APC UPS log source on the JSA Console and use the following table to configure the specific values that are required to collect APC UPS events:

    Table 2: APC UPS Log Source Parameters

    Parameter

    Value

    Log Source type

    APC UPS

    Protocol Configuration

    Syslog

  3. Configure your APC UPS device to forward syslog events to JSA.