APC UPS
The JSA DSM for APC UPS accepts syslog events from the APC Smart-Uninterruptible Power Supply (UPS) family of products.
Events from RC-Series Smart-UPS are not supported.
The following table identifies the specifications for the APC UPS DSM:
Specification |
Value |
---|---|
Manufacturer |
APC |
DSM name |
APC UPS |
RPM file name |
DSM-APCUPS-JSA_version-build_number.noarch.rpm |
Protocol |
Syslog |
Recorded event types |
UPS events Battery events Bypass events Communication events Input power events Low battery condition events SmartBoost events SmartTrim events |
Automatically discovered? |
No |
Includes identity? |
No |
Includes custom properties? |
No |
More information |
To send APC UPS events to JSA, complete the following steps:
If automatic updates are not enabled, download and install the most recent version of the APC UPS DSM RPM from the https://support.juniper.net/support/downloads/ onto your JSA console.
-
Create an APC UPS log source on the JSA Console and use the following table to configure the specific values that are required to collect APC UPS events:
Table 2: APC UPS Log Source Parameters Parameter
Value
Log Source type
APC UPS
Protocol Configuration
Syslog
Configure your APC UPS device to forward syslog events to JSA.