LOGbinder EX Event Collection from Microsoft Exchange Server
The JSA DSM for Microsoft Exchange Server can collect LOGbinder EX V2.0 events.
The following table identifies the specifications for the Microsoft Exchange Server DSM when the log source is configured to collect LOGbinder EX events:
Specification |
Value |
---|---|
Manufacturer |
Microsoft |
DSM name |
Microsoft Exchange Server |
RPM file name |
DSM-MicrosoftExchange-JSA_version-build_number.noarch.rpm |
Supported versions |
LOGbinder EX V2.0 |
Protocol type |
Syslog LEEF |
JSA recorded event types |
Admin Mailbox |
Automatically discovered? |
Yes |
Included identity? |
No |
More information |
Microsoft Exchange website (http://www.office.microsoft.com/en-us/exchange/) |
The Microsoft Exchange Server DSM can collect other types of events. For more information on how to configure for other Microsoft Exchange Server event formats, see the Microsoft Exchange Server topic in the Juniper Secure Analytics Configuring DSMs.
To collect LOGbinder events from Microsoft Exchange Server, use the following steps:
-
If automatic updates are not enabled, download the most recent version of the following RPMs from the Juniper Downloads:
-
DSMCommon RPM
-
Microsoft Exchange Server DSM RPM
-
Configure your LOGbinder EX system to send Microsoft Exchange Server event logs to JSA.
If the log source is not automatically created, add a Microsoft Exchange Server DSM log source on the JSA Console. The following table describes the parameters that require specific values that are required for LOGbinder EX event collection:
Table 2: Microsoft Exchange Server Log Source Parameters for LOGbinder Event Collection Parameter
Value
Log Source type
Microsoft Exchange Server
Protocol Configuration
Syslog
Configuring Your LOGbinder EX System to Send Microsoft Exchange Event Logs to JSA
To collect Microsoft Exchange LOGbinder events, you must configure your LOGbinder EX system to send events to JSA.
Configure LOGbinder EX to collect events from your Microsoft Exchange Server. For more information, see your LOGbinder EX documentation.
Open the LOGbinder EX Control Panel.
Double-click Output in the Configure pane.
Choose one of the following options:
Configure for Syslog-Generic output:
In the Outputs pane, double-click Syslog-Generic.
Select the Send output to Syslog-Generic check box, and then enter the IP address and port of your JSA Console or Event Collector.
Configure for Syslog-LEEF output:
In the Outputs pane, double-click Syslog-LEEF.
Select the Send output to Syslog-LEEF check box, and then enter the IP address and port of your JSA Console or Event Collector.
Click OK.
To restart the LOGbinder service, click the Restart icon.