Configuring Multiservice 4WTO Mode Port Parameters for CTP Bundles (CTPView)
Before you begin:
Log in to the CTPView software at least at the Net_Admin level.
Connect the CTPView server to the CTP device for which you want to configure bundles.
To configure Multiservice 4WTO mode port parameters using CTPView:
- In the side pane, select Bundle > Configuration.
- Run your mouse over the Display and Select an Existing Bundle bar.
- In the table of bundles, select the bundle that you want to modify.
- Under Bundle Options, configure the parameters as described in Table 1.
- Click Click to Submit Bundle AND Port Changes.
Field | Function | Your Action |
---|---|---|
Port Description |
Specifies a description for the port. |
Enter a description of up to 64 alphanumeric characters. Do not use the following characters: ( ; ' " ) ] |
I/F Type |
Specifies the daughter card as the interface type. |
Select DCARD. |
Multi-Service Mode |
Specifies that the bundle will run in 4WTO mode. |
Select 4WTO |
4WTO Mode |
Specifies whether this end of the circuit provides clocking or uses adaptive clocking. If the CTP devices at both ends of the circuit are synchronized, you can configure both ends as Primary. |
Select one:
|
4WTO Channel |
Specifies the channel or channels to enable. Each CTP bundle can support either one or two channels. |
Select one:
|
4WTO Sample Rate [ KHz ] |
Sample rate for audio circuits in kilohertz. The sample rate determines the audio quality and the network bandwidth needed. |
Sample rate is fixed at 8 KHz, which corresponds to standard toll quality voice. |
4WTO μ-law Encoding |
4WTO μ-law encoding is not configurable. |
4WTO μ-law encoding is fixed at DISABLED. |
4WTO Squelch |
Enables or disables the active squelch function on the circuit. If enabled, specifies whether the squelch is active or inactive. The squelch function gates local audio output when DSR-A (channel 0) or RTS-A (channel 1) inputs are active or inactive. |
Select one:
|
4WTO Channel 0 Output Level |
Specifies the output level for channel 0. Note the following information about the values:
|
Enter a number from 0 through 255. |
4WTO Channel 1 Output Level |
Specifies the output level for channel 1. Note the following information about the values:
|
Enter a number from 0 through 255. |