SSR400 Routers Power System
The power system for the SSR400 routers includes an AC power supply adapter (PSA) and related power cords and cables. The AC power adapter operates within certain ranges and the chassis is equipped with a status indicator LED.
The SSR400 routers receive power from an external source. You must use an AC to DC, 180-W power supply adapter (PSA) provided by Juniper Networks to provide power to the appliances. The adapter provides an output of 54 volts direct current (VDC) at 3.3 amperes (A).
| Specification | Value |
|---|---|
|
Maximum power output |
180 W |
|
Input voltage |
100–240 VAC |
|
Input current rating |
2.6 A at 100 VAC |
|
Input line frequency |
50-60 Hz |
| SSR Model | Maximum System Power Consumption | Typical System Power Consumption |
|---|---|---|
|
SSR400 |
107 W |
85 W |
Supported AC Power Cords
A detachable AC power cord is supplied with the device. The coupler is type C13 as described by International Electrotechnical Commission (IEC) standard 60320. The plug end of the power cord fits into the power source outlet that is standard for your geographical location.
| Locale | Cord Set Rating | Plug Standard |
|---|---|---|
|
Argentina |
250 VAC, 10 A, 50 Hz |
IRAM 2073 Type RA/3 |
|
Australia |
250 VAC, 10 A, 50 Hz |
AS/NZZS 3112 Type SAA/3 |
|
Brazil |
250 VAC, 10 A, 50 Hz |
NBR 14136 Type BR/3 |
|
China |
250 VAC, 10 A, 50 Hz |
GB 1002-1996 Type PRC/3 |
|
Continental Europe |
250 VAC, 10 A, 50 Hz or 60 Hz |
EN 60320/Type C13 |
|
India |
250 VAC, 10 A, 50 Hz |
IS 1293 Type IND/3 |
|
Israel |
250 VAC, 10 A, 50 Hz |
SI 32/1971 Type IL/3G |
|
Italy |
250 VAC, 10 A, 50 Hz |
CEI 23-16 Type I/3G |
|
Japan |
125 VAC, 12 A, 50 Hz or 60 Hz |
JIS C8303 |
|
Korea |
250 VAC, 10 A, 50 Hz or 60 Hz |
KSC8305 |
|
South Africa |
250 VAC, 10 A, 50 Hz |
SABS 164/1:1992 Type ZA/13 |
|
Switzerland |
250 VAC, 10 A, 50 Hz |
SEV 6534-2 Type 12G |
|
Taiwan |
125 VAC, 13 A, 60 Hz |
NEMA 5-15 Type N5-15 |
|
International (except India) |
250 VAC, 10 A, 50 Hz |
EN 60320/Type C13 |
|
United Kingdom |
250 VAC, 10 A, 50 Hz |
BS 1363/A Type BS89/13 |
|
USA |
125 VAC, 13 A, 60 Hz |