QFX5100 Cable and Pinout Specifications
Cable Specifications for Console and Management Connections for the QFX Series
Table 1 lists the specifications for the cables that connect the QFX Series switch to a management device.
The QFX Series can be configured with SFP management ports that support 1000BASE-SX transceivers. See the Hardware Compatibility Tool for more on the fiber-optic cables required for use with these transceivers.
Port on QFX Series Device |
Cable Specification |
Cable Supplied |
Maximum Length |
Device Receptacle |
---|---|---|---|---|
Console port |
RS-232 (EIA-232) serial cable |
One 7-foot (2.13-meter) long RJ-45 patch cable and RJ-45 to DB-9 adapter |
7 feet (2.13 meters) |
RJ-45 |
Management port |
Category 5 cable or equivalent suitable for 1000BASE-T operation |
One 7-foot (2.13-meter) long RJ-45 patch cable |
328 feet (100 meters) |
RJ-45 |
RJ-45 Management Port Connector Pinout Information
Table 2 provides the pinout information for the RJ-45 connector for the management port on Juniper Networks devices.
Pin |
Signal |
Description |
---|---|---|
1 |
TRP1+ |
Transmit/receive data pair 1 |
2 |
TRP1- |
Transmit/receive data pair 1 |
3 |
TRP2+ |
Transmit/receive data pair 2 |
4 |
TRP3+ |
Transmit/receive data pair 3 |
5 |
TRP3- |
Transmit/receive data pair 3 |
6 |
TRP2- |
Transmit/receive data pair 2 |
7 |
TRP4+ |
Transmit/receive data pair 4 |
8 |
TRP4- |
Transmit/receive data pair 4 |
Console Port Connector Pinouts for the QFX Series
The console port (labeled CON, or CONSOLE) is an RS-232 serial interface that uses an RJ-45 connector to connect to a console management device. The default baud rate for the console port is 9600 baud.
Table 3 provides the pinout information for the RJ-45 console connector. An RJ-45 cable and RJ-45 to DB-9 adapter are supplied with the QFX Series device.
If your laptop or PC does not have a DB-9 plug connector pin and you want to connect your laptop or PC directly to a QFX Series device, use a combination of the RJ-45 cable and RJ-45 to DB-9 adapter supplied with the device and a USB to DB-9 plug adapter. You must provide the USB to DB-9 plug adapter.
Pin |
Signal |
Description |
---|---|---|
3 |
TxD Output |
Transmit data |
4 |
Signal Ground |
Signal ground |
5 |
Signal Ground |
Signal ground |
6 |
RxD Input |
Receive data |
Copper Cable Specifications for QFX5100-48T and QFX5100-48TH Switches
The QFX5100-48T and QFX5100-48TH switches have 10GBASE-T interfaces that use various types of copper network cables. To achieve optimal performance, you must use cables that conform to IEEE 802.3-2012 specifications for connections for 10GBASE-T network ports. Table 4 lists the cable specifications for 10GBASE-T port on QFX5100-48T and QFX5100-48TH switches.
Ports on Switches |
IEEE Cable Standard |
Shield or Unshielded Twisted Pair (STP/UTP) |
Cable Standard Specification |
Maximum Reach |
Frequency (MHz) |
Additional Information |
---|---|---|---|---|---|---|
10GBASE-T |
Class F/ CAT 7 |
STP |
ISO/IEC 11801:2002 |
328 ft (100 m) |
1–600 |
|
Class EA/ CAT 6A |
STP/UTP |
ANSI/TIA/EIA-568-B2-10 |
328 ft (100 m) |
1–500 |
||
Class E/ CAT 6 |
UTP |
ANSI/TIA/EIA 568-B.2-1 |
98 ft (30 m) |
1–250 |
CAT 6 cables are defined to perform at frequencies up to 250 MHz and are sensitive to alien crosstalk. To use such cables to connect to 10GBASE-T ports, you must ensure that the cable installation is tested and is certified for 500 MHz as per TIA TSB-155 standard. |
|
Class E/ CAT 6 |
STP |
ANSI/TIA/EIA 568-B.2-1 |
98 ft (30 m) |
1–250 |
||
1000BASE-T |
CAT 5eCAT 6CAT 6A (STP/UTP) |
STP/UTP |
ANSI/TIA/EIA-568-AANSI/TIA/EIA-568-B.2-1ANSI/TIA/EIA-568-B2-10 |
328 ft (100 m) |
1-1001-2501-500 |
|
100BASE-TX |
CAT 5eCAT 6CAT 6A (STP/UTP) |
STP/UTP |
ANSI/TIA/EIA-568-AANSI/TIA/EIA-568-B.2-1ANSI/TIA/EIA-568-B2-10 |
328 ft (100 m) |
1-1001-2501-500 |
See Also
USB Port Specifications for the QFX Series
The following Juniper Networks USB flash drives have been tested and are officially supported for the USB port in the QFX Series:
RE-USB-1G-S—1-gigabyte (GB) USB flash drive (except QFX3100 Director device)
RE-USB-2G-S—2-GB USB flash drive (except QFX3100 Director device)
RE-USB-4G-S—4-GB USB flash drive
Any USB memory product not listed as supported for the QFX Series has not been tested by Juniper Networks. The use of any unsupported USB memory product could expose your device to unpredictable behavior. Juniper Networks Technical Assistance Center (JTAC) can provide only limited support for issues related to unsupported hardware. We strongly recommend that you use only supported USB flash drives.
Remove the USB flash drive before upgrading Junos OS or rebooting a QFX Series device. Failure to do so could expose your device to unpredictable behavior.
Executing the request system snapshot
CLI command
on a QFX3500 device requires an external USB flash drive with at least
4 GB of free space. We recommend using the RE-USB-4G-S flash drive.
USB flash drives used with the QFX Series device must support USB 2.0 or later.