RJ-45 Connector Pinouts for an MX Series CB-RE or RCB Management Port
The port on the Control Board and Routing Engine (CB-RE; Routing and Control Board (RCB)) labeled MGMT is an autosensing 10/100/1000-Mbps Ethernet RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or other device that supports out-of-band management).
In routers where the Routing Engine and Control Board (CB) are integrated into a single board, a CB-RE is known as Routing and Control Board (RCB). The RCB is a single FRU that provides Routing Engine and CB functionality.
Table 1 describes the RJ-45 connector pinout.
Pin |
Signal |
Description |
---|---|---|
1 |
TRP1+ |
Transmit/receive data pair 1 |
2 |
TRP1– |
Transmit/receive data pair 1 |
3 |
TRP2+ |
Transmit/receive data pair 2 |
4 |
TRP3+ |
Transmit/receive data pair 3 |
5 |
TRP3– |
Transmit/receive data pair 3 |
6 |
TRP2– |
Transmit/receive data pair 2 |
7 |
TRP4+ |
Transmit/receive data pair 4 |
8 |
TRP4– |
Transmit/receive data pair 4 |