MX104 AC Power Electrical Safety Guidelines and Warnings

The following electrical safety guidelines apply to an AC-powered router:

  • You can order three-wire electrical cords with a grounding-type plug that fits only a grounding-type power outlet. Do not circumvent this safety feature. Equipment grounding should comply with local and national electrical codes.

  • Each AC power supply has one AC appliance inlet. Each inlet requires a dedicated AC power feed and a dedicated customer-site circuit breaker. For the recommended circuit breaker rating, see MX104 AC Power Specifications.

    Warning:

    The router is pluggable type A equipment installed in a restricted-access location.

  • The power cord serves as the main disconnecting device for the AC-powered device. The socket outlet must be near the AC-powered device and be easily accessible.

  • The cores in the main lead are colored in accordance with the following code:

    • Green and yellow—Earth

    • Blue—Neutral

    • Brown—Live

  • When a router is equipped with two AC power supplies, you must unplug both power cords (one for each power supply) to completely disconnect power to the router.

Warning:

The attached power cable is only for this product. Do not use the cable for another product.