Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

Perform Initial Software Configuration for ACX7020 Routers

Learn to customize the basic configuration using Junos OS Evolved CLI.

You can easily customize the factory-default configuration with just a few commands. Initially, you’ll need to make changes through the console port. After you configure the management port, you can access the ACX7020 using SSH and make additional configuration changes. You can revert to the factory-default configuration whenever you want.

Have the following information ready before you begin customizing the router:

  • Hostname

  • Root authentication password

  • Management port IP address

  • Default gateway IP address

  • IP address and prefix length of remote prefixes

  • (Optional) SNMP read community, location, and contact information

To connect and configure the router from the console:

  1. Verify that the following default serial port settings are configured on your laptop or desktop PC:
    • Baud Rate—9600

    • Flow Control—None

    • Data—8

    • Parity—None

    • Stop Bits—1

    • DCD State—Disregard

  2. Connect the console port on the ACX7020 to a laptop or a desktop PC using the RJ-45 cable and RJ-45 to DB-9 adapter. The console (CON) port is the RJ-45 port on the front panel.
    Note:

    We no longer include the RJ-45 console cable with the DB-9 adapter as part of the device package. If the console cable and adapter are not included in your device package, or if you need a different type of adapter, you can order the following separately:

    • RJ-45 to DB-9 adapter (JNP-CBL-RJ45-DB9)

    • RJ-45 to USB-C adapter (JNP-CBL-RJ45-USBC)

    • RJ-45 to USB-A adapter (JNP-CBL-RJ45-USBA)

    If you want to use RJ-45 to USB-A or RJ-45 to USB-C adapter, you must have an X64 (64-bit) Virtual COM port (VCP) driver installed on your PC. See https://ftdichip.com/drivers/vcp-drivers/ to download the driver.

  3. At the Junos OS Evolved login prompt, type root to log in.

    You don't need to enter a password. If the software boots before you connect your laptop or desktop PC to the console port, you might need to press the Enter key for the prompt to appear.

  4. Start the CLI.
  5. Enter the configuration mode.
  6. Stop the chassis auto-upgrade process.
  7. Stop zero-touch provisioning (ZTP).
    Note:

    ZTP is enabled on the ACX7020 in the factory-default configuration. You must stop ZTP before you configure any settings. Until you assign a root password and perform an initial commit, you might see ZTP-related messages on the console. You can safely ignore these messages while you configure the root password.

  8. Add a password for the root administration user account.
  9. Commit the configuration, and wait for the ZTP process to stop.
    A message appears on the console, confirming that the ZTP process has stopped.
  10. (Optional) Give the router a name. If the name includes spaces, enclose the name in quotation marks (“ ”).
  11. Configure the default gateway.
  12. Configure the IP address and prefix length for the management port on the router. On the ACX7020, the management port (MGMT) is the RJ-45 port on the front panel.
  13. (Optional) Configure specific static routes to remote prefixes if you do not want the remote prefixes to use the default route.
  14. Enable Telnet service, if required.
    Note:

    When Telnet is enabled, you cannot log in to the ACX7020 using root credentials. Root login is allowed only for SSH access.

  15. Enable SSH service.
  16. To allow users to log in to the router as root users through SSH, include the root-login statement.
    Note:

    By default, users are not allowed to log in to the router as root users through SSH.

  17. Commit the configuration.
    Your changed configuration becomes the active configuration for the router.