Technical Documentation

Enabling the BSG Service Package on the PIC or DPC

The BSG can run on Adaptive Services (AS) and MultiServices PICs or on a MultiServices Dense Port Concentrator (MS-DPC). You must enable the BSG service package on the services PIC or DPC before you can configure the BSG software. The name of the BSG service package is jservices-voice.

To enable the BSG service package on a PIC or DPC:

  1. Determine the FPC slot number and the PIC number of the services PIC or DPC on which you want to enable the BSG service package.

    In the following example, the FPC slot number is 0 and the PIC number is 3.

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    .
    .
    .
    FPC 0                                              E-FPC
      PIC 0          REV 11   750-002971   RH1375            4x OC-3 SONET, MM
      PIC 1          REV 12   750-012838   DN0449            4x 1GE(LAN), IQ2
        Xcvr 0       REV 01   740-013111   8142659           SFP-T
        Xcvr 1       REV 01   740-013111   8142630           SFP-T
        Xcvr 2       REV 01   740-013111   8155199           SFP-T
        Xcvr 3       REV 01   740-013111   8154799           SFP-T
      PIC 2          REV 11   750-005724   RH2051            2x OC-3 ATM-II IQ, MM
      PIC 3          REV 15   750-014895   DN3277            MultiServices 100
    .
    .
    .
  2. Enable the jservices-voice package on the PIC or DPC.
    [edit chassis]user@host# set fpc 0 pic 3 adaptive-services service-package extension-provider package jservices-voice
  3. Set the number of megabytes that can be used for the wired process memory, which is virtual memory used to reduce Translation Look-aside Buffer (TLB) misses.
    [edit chassis]user@host# set fpc 0 pic 3 adaptive-services service-package extension-provider wired-process-mem-size 512
  4. Set the number of processing cores dedicated to the control functionality of the jservices-voice application.
    [edit chassis]user@host# set fpc 0 pic 3 adaptive-services service-package extension-provider control-cores 7
  5. Specify that the PIC or DPC not restart if the Routing Engine is swapped.
    [edit chassis]user@host# set no-service-pic-restart-on-failover
  6. Commit your configuration changes. You must perform the commit before you can proceed to configure the IMSG.
    [edit]user@host# commitcommit complete

Published: 2010-04-22