Technical Documentation

Configuring the Data Services PIC or MS-DPC

You need to configure a service interface that is a logical interface on an Adaptive Services (AS) PIC, a MultiServices PIC, or an MS-DPC.

To configure the data services PIC or MS-DPC:

  1. Configure the interface, and enter edit mode for the interface.
    [edit]user@host# edit interfaces sp-1/2/0
  2. Configure a description for the interface.
    [edit interfaces sp-1/2/0]user@host# set description bgf_service
  3. Configure logical unit 0.
    [edit interfaces sp-1/2/0]user@host# set unit 0 family inet
  4. Configure a logical unit and specify the protocol family.
    [edit interfaces sp-1/2/0]user@host# set unit 10 family inet
  5. Configure a logical unit and specify the protocol family.
    [edit interfaces sp-1/2/0]user@host# set unit 20 family inet
  6. Configure system logging on the service interface.
    [edit interfaces sp-1/2/0]user@host# set services-options syslog host local services any
  7. Configure an inactivity timeout for sessions on the service interface.
    [edit interfaces sp-1/2/0 services-options syslog]user@host# set services-options inactivity-timeout 720

You can also configure rules for the BGF within a service set.


Published: 2010-04-13