[an error occurred while processing this directive][an error occurred while processing this directive]

startup-alarm

Syntax

startup-alarm (falling-alarm | rising-alarm | rising-or-falling-alarm);

Hierarchy Level

[edit snmp rmon alarm index]

Release Information

Statement introduced before JUNOS Release 7.4.

Statement introduced in JUNOS Release 9.0 for EX Series switches.

Description

The alarm that can be sent upon entry startup.

Options

falling-alarm—Generated if the first sample after the alarm entry becomes active is less than or equal to the falling threshold.

rising-alarm—Generated if the first sample after the alarm entry becomes active is greater than or equal to the rising threshold.

rising-or-falling-alarm—Generated if the first sample after the alarm entry becomes active satisfies either of the corresponding thresholds.

Default: rising-or-falling-alarm

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.