Technical Documentation

services

Syntax

services severity-level;

Hierarchy Level

[edit interfaces interface-name services-options syslog host hostname]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

Specify the system logging severity level.

Options

severity-level—Assigns a severity level to the facility. Valid entries include:

  • alert—Conditions that should be corrected immediately.
  • any—Matches any level.
  • critical—Critical conditions.
  • emergency—Panic conditions.
  • error—Error conditions.
  • info—Informational messages.
  • notice—Conditions that require special handling.
  • warning—Warning messages.

Usage Guidelines

See Configuring System Logging for Services Interfaces.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Published: 2010-04-28