probe

Syntax

probe owner {test test-name {data-fill data;data-size size;destination-interface interface-name;destination-port port;dscp-code-point dscp-bits;history-size size;moving-average-size number;one-way-hardware-timestamp;probe-count count;probe-interval seconds;probe-type type;routing-instance instance-name;source-address address;target (url | address);test-interval interval;thresholds thresholds;traps traps;}}

Hierarchy Level

[edit services rpm]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

Specify an owner name. The owner name combined with the test name represent a single RPM configuration instance.

Options

owner—Specify an owner name up to 32 characters in length.

The remaining statements are explained separately.

Usage Guidelines

See Configuring RPM Probes.

Required Privilege Level

system—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Published: 2010-04-28