priority-hold-time
Syntax
Hierarchy Level
Release Information
Statement introduced in JUNOS Release 8.1.
Description
Configure a Virtual Router Redundancy Protocol (VRRP) router’s priority hold time to define the minimum length of time that must elapse between dynamic priority changes. If the dynamic priority changes because of a tracking event, the priority hold timer begins. If another tracking event or manual configuration change occurs while the timer is running, the new dynamic priority update is postponed until the timer expires.
Options
seconds—The minimum length of time that must elapse between dynamic priority changes.
- Range: 1 through 3600 seconds
Usage Guidelines
See Configuring a Logical Interface to Be Tracked.
Required Privilege Level
interface—To view this statement in the configuration.