interface (ARP Aging Timer)

Syntax

interface interface-name minutes;

Hierarchy Level

[edit system arp aging-timer]

Release Information

Statement introduced in JUNOS Release 9.4.

Statement introduced in JUNOS Release 9.0 for EX Series switches.

Description

Specify the ARP aging timer in minutes for a logical interface of family type inet.

Options

minutes—Time between ARP updates, in minutes.

Default: 20
Range: 1 through 240

Required Privilege Level

system—To view this statement in the configuration.

system-control—To add this statement to the configuration.


Published: 2010-04-26