interface (ARP Aging Timer)
Syntax
interface interface-name minutes;
Hierarchy Level
[edit system arp aging-timer]
Release Information
Statement introduced in JUNOS Release 9.4.
Statement introduced in JUNOS Release 9.0 for EX Series switches.
Description
Specify the ARP aging timer in minutes for a logical interface of family type inet.
Options
minutes—Time between ARP updates, in minutes.
- Default: 20
- Range: 1 through 240
Required Privilege Level
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.