Technical Documentation

hold-interval (Protection Group)

Syntax

hold-interval number;

Hierarchy Level

[edit protocols protection-group ethernet-ring name]

Release Information

Statement introduced in JUNOS Release 9.4.

Description

Specify the hold-off timer interval for all rings in 100 millisecond (ms) increments.

Options

number—Hold-timer interval, in milliseconds.

Range: 0 through 10,000 ms
Default: 100 ms

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Published: 2010-04-20