Syntax

falling-threshold percentage;

Hierarchy Level

[edit snmp health-monitor]

Release Information

Statement introduced in JUNOS Release 8.0.

Statement introduced in JUNOS Release 9.0 for EX Series switches.

Description

The lower threshold is expressed as a percentage of the maximum possible value for the sampled variable. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval is greater than this threshold, a single event is generated. A single event is also generated if the first sample after this entry becomes valid is less than or equal to this threshold. After a falling event is generated, another falling event cannot be generated until the sampled value rises above this threshold and reaches the rising-threshold.

Options

percentage—The lower threshold for the alarm entry.

Range: 1 through 100
Default: 70 percent of the maximum possible value

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.


Published: 2010-04-27