[an error occurred while processing this directive][an error occurred while processing this directive]

crc-minor-alarm-threshold

Syntax

crc-minor-alarm-threshold (1e-3 | 5e-4 | 1e-4 | 5e-5 | 1e-5 | 5e-6 | 1e-6);

Hierarchy Level

[edit interfaces interface-name t1-options]

Release Information

Statement introduced in JUNOS Release 8.5.

Description

Minor alarm error thresholds for T1 CRC errors. When the threshold is exceeded for one second, a defect condition is declared. If the defect condition continues for the monitoring period, an alarm condition is declared.

Default

10-second monitoring period for values 1e-3, 5e-4, 1e-4, and 5e-5. The 1e-5 value uses a 50-second monitoring period. The 5e-6 value uses a 100-second monitoring period. The 1e-6 value uses a 500-second monitoring period.

Options

rate—Error rate expressed as the number of errors per number of bits. The value 1e-3 is one error in 10–3 bits and 5e-4 is five errors in 10–4 bits.

Default: 5e-6

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Published: 2010-04-20