Technical Documentation

crc-major-alarm-threshold

Syntax

crc-major-alarm-threshold (1e-3 | 5e-4 | 1e-4 | 5e-5 | 1e-5);

Hierarchy Level

[edit interfaces interface-name t1-options]

Release Information

Statement introduced in JUNOS Release 8.5.

Description

Major alarm error thresholds for T1 CRC errors. When the threshold is exceeded for one second, a defect condition is declared. If the defect condition continues for the monitoring period, an alarm condition is declared.

Default

10-second monitoring period for all settings except 1e-5. The 1e-5 value uses a 50-second monitoring period.

Options

rate—Error rate expressed as the number of errors per number of bits. The value 1e-3 is one error in 10-3 bits and 5e-4 is five errors in 10-4 bits.

Default: 5e-5

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Published: 2010-04-20