Technical Documentation

Example: Configuring IEEE 802.3ah OAM Support on an Interface

Configure 802.3ah OAM support on an MX Series 10-Gigabit Ethernet interface:

[edit]protocols {oam {ethernet {link-fault-management {interface xe-0/0/0 {link-discovery active;pdu-interval 800;pdu-threshold 4;remote-loopback;negotiation-options {allow-remote-loopback;}event-thresholds {frame-error 30;frame-period 50;frame-period summary 40;symbol-period 20;}}}}}}

Published: 2010-04-20