-- -- Juniper Enterprise Specific MIB: Interface MIB Extension -- -- Copyright (c) 1999-2003, 2007, Juniper Networks, Inc. -- All rights reserved. -- -- The contents of this document are subject to change without notice. -- JUNIPER-IF-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32, Counter64, Counter32 FROM SNMPv2-SMI CounterBasedGauge64 FROM HCNUM-TC ifEntry,ifIndex FROM IF-MIB TimeStamp FROM SNMPv2-TC jnxMibs FROM JUNIPER-SMI; ifJnx MODULE-IDENTITY LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:51 2003 UTC ORGANIZATION "Juniper Networks, Inc." CONTACT-INFO " Juniper Technical Assistance Center Juniper Networks, Inc. 1194 N. Mathilda Avenue Sunnyvale, CA 94089 E-mail: support@juniper.net" DESCRIPTION "The MIB modules extends the ifTable as defined in IF-MIB." REVISION "200706050000Z" -- 05 June, 2007 DESCRIPTION "New Time Domain Reflectometery Added" REVISION "200210310000Z" -- 31 Oct, 2002 DESCRIPTION "New error counters added to ifJnxTable" REVISION "200106210000Z" -- 21 June, 2001 DESCRIPTION "New objects ifHCIn1SecRate and ifHCOut1SecRate added" REVISION "200103150000Z" -- 15 March, 2001 DESCRIPTION "Initial Version" ::= { jnxMibs 3 } -- -- This table augments ifTable -- ifJnxTable OBJECT-TYPE SYNTAX SEQUENCE OF IfJnxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Juniper's extension to the interface entries. The number of entries is given by the value of ifNumber. This table contains additional objects for the interface table." ::= { ifJnx 1 } ifJnxEntry OBJECT-TYPE SYNTAX IfJnxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional management information applicable to a particular interface." AUGMENTS { ifEntry } ::= { ifJnxTable 1 } IfJnxEntry ::= SEQUENCE { ifIn1SecRate Gauge32, ifIn1SecOctets Gauge32, ifIn1SecPkts Gauge32, ifOut1SecRate Gauge32, ifOut1SecOctets Gauge32, ifOut1SecPkts Gauge32, ifHCIn1SecRate CounterBasedGauge64, ifHCOut1SecRate CounterBasedGauge64, ifJnxInErrors Counter64, ifJnxInFrameErrors Counter64, ifJnxInQDrops Counter64, ifJnxInRunts Counter64, ifJnxInGiants Counter64, ifJnxInDiscards Counter64, ifJnxInHslCrcErrors Counter64, ifJnxInHslFifoOverFlows Counter64, ifJnxInL3Incompletes Counter64, ifJnxInL2ChanErrors Counter64, ifJnxInL2MismatchTimeouts Counter64, ifJnxInInvalidVCs Counter64, ifJnxInFifoErrors Counter32, ifJnxBucketDrops Counter64, ifJnxSramErrors Counter32, ifJnxOutErrors Counter64, ifJnxCollisions Counter64, ifJnxCarrierTrans Counter64, ifJnxOutQDrops Counter64, ifJnxOutAgedErrors Counter64, ifJnxOutFifoErrors Counter32, ifJnxOutHslFifoUnderFlows Counter64, ifJnxOutHslCrcErrors Counter32 } ifIn1SecRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second (bps), delivered by this (sub-)layer to its next higher (sub-)layer." ::= { ifJnxEntry 1 } ifIn1SecOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets per second (Bps, Bytes per second), delivered by this (sub-)layer to its next higher (sub-)layer." ::= { ifJnxEntry 2 } ifIn1SecPkts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets per second (pps), delivered by this (sub-)layer to its next higher (sub-)layer." ::= { ifJnxEntry 3 } ifOut1SecRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second (bps), delivered by this (sub-)layer to its next lower (sub-)layer." ::= { ifJnxEntry 4 } ifOut1SecOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets per second (Bps, Bytes per second), delivered by this (sub-)layer to its next lower (sub-)layer." ::= { ifJnxEntry 5 } ifOut1SecPkts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets per second (pps), delivered by this (sub-)layer to its next lower (sub-)layer." ::= { ifJnxEntry 6 } ifHCIn1SecRate OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second (bps), delivered by this (sub-)layer to its next higher (sub-)layer. This object is a 64 bit version of ifIn1SecRate." ::= { ifJnxEntry 7 } ifHCOut1SecRate OBJECT-TYPE SYNTAX CounterBasedGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second (bps), delivered by this (sub-)layer to its next lower (sub-)layer. This object is a 64 bit version of ifOut1SecRate." ::= { ifJnxEntry 8 } ifJnxInErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Errors: The sum of the incoming frame aborts and FCS errors." ::= { ifJnxEntry 9 } ifJnxInFrameErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Framing Errors: The number of input packets which were misaligned." ::= { ifJnxEntry 10 } ifJnxInQDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Drops: The number of packets dropped by the input queue of the I/O Manager ASIC." ::= { ifJnxEntry 11 } ifJnxInRunts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Runts: Frames received that are smaller than the runt threshold." ::= { ifJnxEntry 12 } ifJnxInGiants OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Giants: Frames received that are larger than the giant threshold." ::= { ifJnxEntry 13 } ifJnxInDiscards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Policed Discards: Frames that the incoming packet match code discarded because they were not recognized or of interest." ::= { ifJnxEntry 14 } ifJnxInHslCrcErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "HS Link CRC Errors: The number of CRC errors on the high-speed links between the ASICs responsible for handling the router interfaces while receiving packets." ::= { ifJnxEntry 15 } ifJnxInHslFifoOverFlows OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "HS link FIFO overflows: The number of FIFO overflows on the high-speed links between the ASICs responsible for handling the router interfaces." ::= { ifJnxEntry 16 } ifJnxInL3Incompletes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "L3 incompletes: The number of incoming packets that fail Layer 3 sanity checks of the header." ::= { ifJnxEntry 17 } ifJnxInL2ChanErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "L2 channel errors: the number of incoming packets for which the sofware could not find a valid logical interface." ::= { ifJnxEntry 18 } ifJnxInL2MismatchTimeouts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "L2 mismatch timeouts: The count of malformed or short packets that cause the incoming packet handler to discard the frame as unreadable." ::= { ifJnxEntry 19 } ifJnxInInvalidVCs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Invalid VCs: Number of cells that arrived for a nonexistent virtual circuit." ::= { ifJnxEntry 20 } ifJnxInFifoErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FIFO errors: The number of FIFO errors in the receive direction as reported by the ASIC on the PIC." ::= { ifJnxEntry 21 } ifJnxBucketDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Bucket drops: Drops due to traffic load exceeding the interface transmit/receive leaky bucket configuration." ::= { ifJnxEntry 22 } ifJnxSramErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "SRAM errors: This counter increments when a hardware error has occurred in the SRAM on the PIC." ::= { ifJnxEntry 23 } ifJnxOutErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Errors: The sum of the outgoing frame aborts and FCS errors." ::= { ifJnxEntry 24 } ifJnxCollisions OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Collisions: The number of output collisions detected on this interface." ::= { ifJnxEntry 25 } ifJnxCarrierTrans OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Carrier transitions: The number of times the interface saw the carrier signal transition." ::= { ifJnxEntry 26 } ifJnxOutQDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Drops: The number of packets dropped by the output queue of the I/O Manager ASIC." ::= { ifJnxEntry 27 } ifJnxOutAgedErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Aged packets: The number of packets that remained in shared packet SDRAM for so long that the system automatically purged them." ::= { ifJnxEntry 28 } ifJnxOutFifoErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FIFO errors: The number of FIFO errors in the transmit direction as reported by the ASIC on the PIC." ::= { ifJnxEntry 29 } ifJnxOutHslFifoUnderFlows OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "HS link FIFO underflows: The number of FIFO underflows on the high-speed links between the ASICs responsible for handling the router interfaces." ::= { ifJnxEntry 30 } ifJnxOutHslCrcErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "HS Link CRC Errors: The number of CRC errors on the high-speed links between the ASICs responsible for handling the router interfaces while transmitting packets." ::= { ifJnxEntry 31 } -- -- This table augments ifTable to map to Chassis MIB tables -- ifChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF IfChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Juniper's extension to the interface entries. The number of entries is given by the value of ifNumber. This table contains additional objects for the interface table to facilitate the identification of interfaces and its mapping into the Chassis MIB tables." ::= { ifJnx 2 } ifChassisEntry OBJECT-TYPE SYNTAX IfChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional management information applicable to a particular interface." AUGMENTS { ifEntry } ::= { ifChassisTable 1 } IfChassisEntry ::= SEQUENCE { ifChassisFpc Integer32, ifChassisPic Integer32, ifChassisPort Integer32, ifChassisChannel Integer32, ifChassisLogicalUnit Integer32, ifChassisPicIndex OCTET STRING } ifChassisFpc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the FPC card on which the interface is located in the chassis. It is the chassis slot in which the FPC card is installed for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical FPC associated with the specified interface." ::= { ifChassisEntry 1 } ifChassisPic OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the PIC card on which the interface is located in the chassis. It is the PIC location on the FPC card for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical PIC associated with the specified interface." ::= { ifChassisEntry 2 } ifChassisPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the port on the PIC card on which the interface is located in the chassis. It is the port number on the PIC card for the specified interface. Although the number is labeled from 0 and up in the chassis, the return value for this object always starts from 1 according to Network Management convention. Therefore, a value of zero means there is no real or physical port associated with the specified interface." ::= { ifChassisEntry 3 } ifChassisChannel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel identifier for the specified interface if and only if it is part of a channelized interface. Although the channel is numbered from 0 and up in the interface naming, the return value for this object always starts from 1 according to Network Management convention. For the interface which could not be channelized, this object returns zero." ::= { ifChassisEntry 4 } ifChassisLogicalUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The logical unit number of the specified interface. It is the logical part of the interface that is configured on the physical or channel part if any. Although the logical unit number is numbered from 0 and up in the interface naming, the return value for this object always starts from 1 according to Network Management convention. For the interface which is really a physical device, this value returns zero." ::= { ifChassisEntry 5 } ifChassisPicIndex OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The index or indices for the Chassis MIB tables. This is the instance index which keys into the jnxContentsTable in Chassis MIB. For example, it could return an octet string of '8.1.2.0' - meaning a PIC ('8', first digit) at FPC slot 0 ('1-1', second digit minus one if nonzero) PIC number 1 ('2-1', third digit minus one if nonzero) port number whatever (fourth digit currently unused) - which in turn could be plugged in by NMS directly after any MIB objects in the jnxContentsTable, say 'jnxContentsDescr.8.1.2.0', so NMS could get that PIC object for the specified interface. This object is valid only for those interfaces having real and physical PIC cards. Otherwise, it returns an octet string of four zeros '0.0.0.0.'" ::= { ifChassisEntry 6 } END