Media Flow Controller MIB Definitions : Variables

Variables
system OBJECT IDENTIFIER
::= { variables 1 }
systemVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System software version string"
::= { system 1 }
cpu OBJECT IDENTIFIER
::= { system 2 }
cpuLoad1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One-minute CPU load in hundreths"
::= { cpu 1 }
cpuLoad5 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Five-minute CPU load in hundreths"
::= { cpu 2 }
cpuLoad15 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fifteen-minute CPU load in hundreths"
::= { cpu 3 }
cpuUtil1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage CPU utilization, aggregated across all CPUs, rolling average over the past minute"
::= { cpu 4 }
procmgr OBJECT IDENTIFIER
::= { system 3 }
procTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of processes managed or monitored by PM"
::= { procmgr 1 }
procEntry OBJECT-TYPE
SYNTAX ProcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for one process"
INDEX { procIndex }
::= { procTable 1 }
ProcEntry ::=
SEQUENCE {
procIndex Unsigned32,
procName OCTET STRING,
procStatus OCTET STRING,
procNumFailures Unsigned32
}
procIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synthetic numeric unique ID of process"
::= { procEntry 1 }
procName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique name of process"
::= { procEntry 2 }
procStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of process"
::= { procEntry 3 }
procNumFailures OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times process has crashed or exited unexpectedly"
::= { procEntry 4 }
cmc OBJECT IDENTIFIER
::= { variables 2 }
applTable OBJECT-TYPE
SYNTAX SEQUENCE OF ApplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of appliances managed by the CMC"
::= { cmc 1 }
applEntry OBJECT-TYPE
SYNTAX ApplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for one managed appliance"
INDEX { applIndex }
::= { applTable 1 }
ApplEntry ::=
SEQUENCE {
applIndex Unsigned32,
applName OCTET STRING,
applConnected TruthValue,
applOK Unsigned32
}
applIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synthetic numeric unique ID of appliance"
::= { applEntry 1 }
applName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual ID/name of appliance"
::= { applEntry 2 }
applConnected OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is CMC connected to this appliance (1=yes, 2=no)"
::= { applEntry 5 }
applOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Did this appliance pass its most recent status check (1=yes, 2=no)"
::= { applEntry 6 }
 

Report an Error
Media Flow Controller Administrator's Guide and CLI Command Reference
Copyright © 2010 Juniper Networks, Inc.