Monitoring Cluster Status

Purpose

Use the monitoring functionality to view the cluster status page.

Action

To monitor cluster status select, Monitor>System View>Cluster Status in the J-Web user interface.

Meaning

Table 199 summarizes key output fields on the cluster status page.

Table 199: Cluster Status Monitoring Page

Field

Value

Additional Information

Refresh Interval (sec)

Displays the time interval set for page refresh.

Select the time interval from the drop-down list.

Refresh

Displays the option to refresh the page.

Cluster Status

Redundancy Group

Displays the redundancy group specified for the chassis cluster.

Failover

Displays the failover options selected.

  • Counter— Displays the number of times chassis cluster failed.

    Action—Displays the active tool for users to fail over chassis cluster.

Primary

Displays the node used for the chassis cluster.

Switch

Provides an option to switch between the primary and secondary nodes.

Status

Displays the state of the redundancy group for node 0 and node 1. The possible states are:

  • Primary—Redundancy group is active and passing traffic.
  • Secondary—Redundancy group is passive and not passing traffic.
  • Lost—Node loses contact with the other node through the control link. Most likely to occur when both nodes are in a cluster one node is rebooted, or, because of a control link failure, one node cannot exchange heartbeats with the other node.
  • Unavailable—Node has not received a single heartbeat over the control link from the other node since the other node booted up. Most likely to occur when one node boots up before the other node or if only one node is present in the cluster.

Preempt

Displays the preempt option selected to initiate a failover for node 0 and 1. The possible preempt options are:

  • Yes—Mastership can be preempted based on priority.
  • No—Mastership cannot be preempted if the priority changes.

Manual Failover

Displays the priority value of node 0 for manual failover. The possible manual failover options are:

  • Yes—If the mastership is set manually, it overrides the Priority and Preempt options.
  • No—Mastership is not set manually.

Interface Monitoring

I/F

Displays the interfaces monitored by the redundancy group and shows their respective weights.

Weight

Displays the weight for the interface to be monitored.

Status

Displays the status of the interface.