Upgrading Both Devices in a Chassis Cluster Using a Low-Impact ISSU
- Upgrading Both Devices in a Chassis Cluster Using an ISSU
- Rolling Back Devices in a Chassis Cluster After an ISSU
- Guarding Against Service Failure in a Chassis Cluster ISSU
- Enabling an Automatic Chassis Cluster Node Failback After an ISSU
- Troubleshooting Chassis Cluster ISSU Failures
- Deciphering Mismatched Control Link Statistics During a Chassis Cluster ISSU
Upgrading Both Devices in a Chassis Cluster Using an ISSU
For some platforms, devices in a chassis cluster can be upgraded without a service disruption using an in-service software upgrade (ISSU). The chassis cluster ISSU feature allows both devices in a cluster to be upgraded from supported Junos OS versions with a traffic impact similar to that of redundancy group failovers.
![]() | Note: ISSU does not support software downgrades. |
![]() | Note: If you upgrade from a Junos OS version that supports only IPv4 to a version that supports both IPv4 and IPv6, the IPv4 traffic will continue to work during the upgrade process. If you upgrade from a Junos OS version that supports both IPv4 and IPv6 to a version that supports both IPv4 and IPv6, both the IPv4 and IPv6 traffic will continue to work during the upgrade process. Junos OS Release 10.2 and later releases support flow-based processing for IPv6 traffic. For more information, see “Enabling Flow-Based Processing for IPv6 Traffic” in the Junos OS Security Configuration Guide. |
Before you begin, note the following:
- The ISSUs are available only for Junos OS Release 9.6 and later.
- Before starting an ISSU, you should fail over all redundancy groups so that they are all active on only one device. SeeInitiating a Chassis Cluster Manual Redundancy Group Failover
- We recommend that routing protocols graceful restart be enabled prior to starting an ISSU.
Once all redundancy groups are active on one device, the upgrade is initiated by using a request command:
- Fail over all redundancy groups to one device.
- Start the ISSU by entering the following command:user@host> request system software in-service-upgrade image_name reboot
If reboot is not included in the command, you need to manually reboot each device as the ISSU completes the software image update.
- Wait for both devices to complete the upgrade, then verify that all policies, zones, redundancy groups, and other RTOs return to their correct states. Also verify that both devices in the cluster are running the new Junos OS build.
![]() | Note: During the upgrade, both devices might experience redundancy group failovers, but traffic is not disrupted. Each device validates the package and checks version compatibility before doing the upgrade. If the system finds that the new package is not version compatible with the currently installed version, the device refuses the upgrade or prompts you to take corrective action. Sometimes a single feature is not compatible, in which case the upgrade software prompts you to either abort the upgrade or turn off the feature before doing the upgrade. |
This feature is available only through the command-line interface. See the “request system software in-service-upgrade” section of the Junos OS CLI Reference.
Rolling Back Devices in a Chassis Cluster After an ISSU
If the ISSU fails to complete and only one device in the cluster has been upgraded, you can roll back to the previous configuration on that device alone by using the following commands on the upgraded device:
- request chassis cluster in-service-upgrade abort
- request system software rollback
- request system reboot
Guarding Against Service Failure in a Chassis Cluster ISSU
The ISSU command has one option: no-old-master-upgrade. This option leaves the current master device in a nonupgraded state, which is a precaution against service failure. The no-old-master-upgrade option allows routing control to be quickly returned to the old master device if the newly upgraded device does not operate correctly.
Use of the no-old-master-upgrade option requires that you run a standard upgrade on the old master device after the ISSU is completed on the backup device.
If you use the no-old-master-upgrade option, when the backup device completes its upgrade and you are confident that the new build is operating as expected, then upgrade the old master as follows:
- Run request system software add image_name.
- Run request chassis cluster in-service-upgrade abort to stop the ISSU process.
- Run request system reboot.
Enabling an Automatic Chassis Cluster Node Failback After an ISSU
If you want redundancy groups to automatically return to node 0 as the primary after the ISSU is complete, you must set the redundancy group priority such that node 0 is primary and enable the preempt option. Note that this method works for all redundancy groups except redundancy group 0. You must manually fail over redundancy group 0. To set the redundancy group priority and enable the preempt option, see Example: Configuring Chassis Cluster Redundancy Groups (CLI). To manually fail over a redundancy group, see Initiating a Chassis Cluster Manual Redundancy Group Failover.
![]() | Note: To upgrade node 0 and make it available in the chassis cluster, manually reboot node 0. Node 0 does not reboot automatically. |
Troubleshooting Chassis Cluster ISSU Failures
Certain circumstances might cause an ISSU attempt to fail. This section explains two of them.
- If you attempt to upgrade a device pair running a Junos OS image earlier than Release 9.6, the ISSU will fail without changing anything about either device in the cluster. Devices running Junos OS Releases earlier than 9.6 must be upgraded separately using individual device upgrade procedures.
- If the secondary device experiences a power-off condition before it boots up using the new image specified when the ISSU is initiated, when power is restored the newly upgraded device will still be waiting to end the ISSU. To end the ISSU on the secondary device, run request chassis cluster in-service-upgrade abort followed by reboot to abort the ISSU on that device.
Deciphering Mismatched Control Link Statistics During a Chassis Cluster ISSU
When using dual control links (supported on the SRX5000 and SRX3000 lines only), mismatched control link statistics might be reported with the show chassis cluster statistics and show chassis cluster control-plane statistics commands while you run an ISSU with nodes on devices running different releases. (ISSUs are available in Junos OS Release 9.6 and later and dual control links are available in Junos OS Release 10.0 and later.) For example, assume that one node on a device is running Junos OS Release 9.6 and another node on a device is running Junos OS Release 10.0. In this example, a mismatch might occur because the latter device is sending heartbeats on both control links, but the other device is receiving heartbeats only on one control link.
Related Topics
- Junos OS Feature Support Reference for SRX Series and J Series Devices
- Upgrading Each Device in a Chassis Cluster Separately
- Disabling Chassis Cluster
Hide Navigation Pane
Show Navigation Pane
Download
SHA1
