Example: Configuring Chassis Cluster with a Dampening Time Between Back-to-Back Redundancy Group Failovers (CLI)
Although back-to-back redundancy group failovers have a default dampening time, you can configure it. For redundancy group 0, the default interval is 5 minutes (300 seconds), with a range of 300 through 1800 seconds. For redundancy group x (redundancy groups 1 through 128), the default interval is 1 second, with a range of 0 through 1800 seconds.
Use the following command to set the minimum interval (in seconds) to be allowed between back-to-back failovers for redundancy group 0:
{primary:node1}user@host# set chassis cluster redundancy-group
0 hold-down-interval 420
Related Topics
- Junos OS Feature Support Reference for SRX Series and J Series Devices
- Understanding Chassis Cluster Redundancy Group Manual Failover
- Initiating a Chassis Cluster Manual Redundancy Group Failover
- Understanding SNMP Failover Traps for Chassis Cluster Redundancy Group Failover
- Understanding Chassis Cluster Redundant Ethernet Interfaces