T3 or E3 PIM
The T3 (also known as DS3) PIM (Figure 32) and E3 PIM (Figure 33) provide
a physical connection to T3 or E3 network media types. The T3 and
E3 PIMs include one physical T3 or E3 port with an integrated data
service unit (DSU).
Figure 32: T3 PIM

Figure 33: E3 PIM

The T3 and E3 PIMs provide the following key features:
- Onboard network processor
- Integrated DSU—Eliminates the need for a separate
external device
- Subrate and scrambling options with support for major
DSU vendors
- Independent internal and external clocking system
- Loopback (payload–supported only on T3 PIM, local,
and remote), bit error rate test (BERT), and T3 far-end alarm and
control (FEAC) diagnostics
For pinouts of cable connectors for T3 and E3 PIMs, see E3 and T3 BNC Connector Pinout.
To install or remove a PIM, see Replacing a PIM.
Status LEDs indicate port status. Table 28 describes the meaning of the LED states.
Table 28: Status LEDs for T3 and E3 Ports
|
Color
|
State
|
Description
|
|
Green
|
On steadily
|
Online with no alarms or failures.
|
|
Red
|
On steadily
|
Active with a local alarm. The router has detected a failure.
|
|
Yellow
|
On steadily
|
- Loopback mode.
- T3 (DS3)—Remote endpoint is in red alarm failure.
- E3—Remote defect indication (RDI).
|
|
Unlit
|
Off
|
Offline.
|
For alarms, see the configuring and monitoring alarms information
in the J-series Services Router Administration Guide.
[