The J2350 Services Router uses either AC or DC power. The autosensing power supply (see Figure 4 or Figure 5) distributes the different output voltages to the router components according to their voltage requirements. The power supply is fixed in the chassis, and is not field-replaceable.
The AC power supply has a single AC appliance inlet that requires a dedicated AC power feed. The DC power supply has a terminal block that provides a single DC input (–48 VDC and return) and requires a dedicated 15 A (–48 VDC) circuit breaker.
The J2350 AC-powered or DC-powered chassis has a power switch and does not include a power LED.
For information about site power preparations, see Power Guidelines, Requirements, and Specifications. For information about connecting the router to power and ground, see Connecting Power.
![]() |
Note: You cannot mix DC and AC power supplies in the same chassis. |
![]() |
Warning: DC-powered Services Routers are intended for installation only in a restricted access location. |