To install a Crypto Accelerator Module:

  1. Take the following steps if you have not already done so:
    1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground. For more information about ESD, see Preventing Electrostatic Discharge Damage.
    2. Press and release the power button to power off the Services Router. Wait for the POWER LED to turn off.
    3. Unplug the power cord or cable from the power source receptacle.
    4. Remove the chassis cover. (See Removing and Replacing the Chassis Cover on J2320 and J2350 Routers.)
  2. Locate the Crypto Module connector on the system board (see Figure 97).
  3. Remove the Crypto Module from its electrostatic bag.
  4. Align the notches in the Crypto Module with the notches in the connector on the system board and push the Crypto Module down flat, as shown in Figure 97.

    Figure 97: Installing a J2320 or J2350 Crypto Accelerator Module

    Image g004115.gif

  5. Insert the three screws and tighten them until snug. Do not overtighten.
  6. Replace the chassis cover. (See Removing and Replacing the Chassis Cover on J2320 and J2350 Routers.)
  7. Replace the power cord or cable.
  8. Press and release the power button to power on the router. Verify that the POWER LED lights steadily.
  9. Verify that the Crypto Module is correctly installed by issuing the show chassis hardware command, as shown in the following example:
    user@host> show chassis hardware
    user@host> show chassis hardware 
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                JN1092BAEADB      J6350
    Midplane         REV 03   710-014593   NR2489
    System IO        REV 01   710-016210   NL3304            JX350 System IO
    Crypto Module                                            Crypto Acceleration
    Routing Engine   REV 08   710-015273   NM4265            RE-J6350-3400
    FPC 0                                                    FPC
      PIC 0                                                  4x GE Base PIC
    FPC 6            REV 00   750-015152                     FPC
      PIC 0                                                  6x GE SFP uPIM
        Xcvr 0                NON-JNPR     PC14DP3           SFP-SX
        Xcvr 2                NON-JNPR     PC21M3E           SFP-SX
    Power Supply 0
    

    If Crypto Module appears in the output, the Crypto Accelerator Module is installed correctly.


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]