Connecting Power
J2320, J2350 and J4350 Services Routers have a single fixed power
supply. J6350 Services Routers have one or two field-replaceable
power supplies. For more information about the J-series power specifications,
see Power Guidelines, Requirements, and Specifications.
 |
Warning:
DC-powered Services Routers
are intended for installation only in a restricted access location.
|
Connecting AC Power
The router must be connected to earth ground during normal operation.
The protective earthing terminal on the rear of the chassis is provided
to connect the router to ground. Additional grounding is provided
to an AC-powered router when you plug its power supply into a grounded
AC power receptacle.
The AC power cord shipped with the router connects the router to
earth ground when plugged into an AC grounding-type power outlet.
The router must be connected to earth ground during normal operation.
For power cord requirements, see AC Power, Connection, and Power Cord Specifications.
To connect AC power to the router:
- Attach an electrostatic discharge (ESD) grounding
strap to your bare wrist, and connect the strap to the ESD point on
the chassis. For more information about ESD, see Preventing Electrostatic
Discharge Damage.
- Use a grounding cable to connect the router to
earth ground: (For cable requirements, see Chassis Grounding.)
- Verify that a licensed electrician has attached an appropriate
grounding cable lug to the grounding cable.
- Connect one end of the grounding cable to a proper earth
ground, such as the rack in which the router is installed.
- With a Phillips screwdriver, remove the screw and washer from the PEM
nuts at the grounding point on the rear of the chassis.
- Place the grounding lug at the other end of the cable
over the grounding point, as shown in Figure 62 through Figure 64.
- Secure the cable lug to the grounding point, first with
the washer, then with the screw. On J2320 and J2350 routers, use the
screw containing a captive washer to secure the cable lug to the grounding
point.
- Locate the power cord or cords shipped with the router,
which has a plug appropriate for your geographical location. For power
cord specifications, see Power Guidelines, Requirements, and Specifications.
- For the power supply:
- Insert the appliance coupler end of a power cord into
the appliance inlet on the power supply faceplate, as shown in Figure 62 through Figure 64.
- Insert the plug into an AC power source receptacle.
- Verify that the power cord does not block access
to router components or drape where people can trip on it.
- On J2320 and J2350 routers, use the power cable
tie as follows to relieve strain on the cable (see Figure 62 and Figure 63):
- Wrap the loose end of the tie around the cable, and insert
it into the opening on the tie.
- Pull the end to tighten the tie.
To release the tie from the cable, press down the tab on the
tie and loosen it.
Figure 62: Connecting AC Power
to the J2320 Services Router

Figure 63: Connecting AC Power to the
J2350 Services Router

Figure 64: Connecting AC Power to the J4350 or J6350 Services Router

Connecting DC Power
 |
Caution:
If your J6350 Services Router includes an optional
redundant DC power supply, connect each of the two power supplies
to different input power sources. Failure to do so makes the router susceptible
to total power failure if one of the power supplies fails.
|
The router must be connected to earth ground during normal operation.
The protective earthing terminal on the rear of the chassis is provided
to connect the router to ground.
For DC cable requirements, see DC Power, Connection, and Power Cable Specifications.
To connect DC power to the router:
- Attach an electrostatic discharge (ESD) grounding
strap to your bare wrist, and connect the strap to the ESD point on
the chassis. For more information about ESD, see Preventing Electrostatic
Discharge Damage.
- Use a grounding cable to connect the router to
earth ground: (For cable requirements, see Chassis Grounding.)
- Verify that a licensed electrician has attached an appropriate
grounding cable lug to the grounding cable.
- Connect one end of the grounding cable to a proper earth
ground, such as the rack in which the router is installed.
- With a Phillips screwdriver, remove the screw and washer
from the PEM nut at the grounding point on the rear of the chassis.
- Place the grounding lug at the other end of the cable
over the grounding point, as shown in Figure 65 and Figure 66.
- Secure the cable lug to the grounding point, first with
the washer, then with the screw. On J2320 and J2350 routers, use the
screw containing a captive washer to secure the cable lug to the grounding
point.
 |
Note:
A DC power supply in a Services Router becomes grounded
when you connect a grounding cable between the router and earth
ground.
|
- For each power supply:
- Ensure that the voltage across the DC power source cable
leads is 0 V and that the cable leads cannot become active in any
way during installation.
 |
Caution:
You must ensure that power connections maintain the proper polarity.
The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for
DC power cables. The color coding used by the external DC power source
at your site determines the color coding for the leads on the power
cables that attach to the terminal studs on each power supply.
|
- Verify that a licensed electrician has attached the appropriate
power cable lugs to the negative and positive DC source power cables.
- Use a Phillips screwdriver to remove the clear plastic
cover protecting the terminal block.
- Within the terminal block, remove the two center screws
next to the labels –48 VDC and RTN.
Each screw contains a captive washer to secure a DC source power
cable lug to the terminal block.
- Using one of the removed screws, secure the positive (+)
DC source power cable lug to the RTN terminal. Tighten the
screw until snug. Do not overtighten. Apply between 8 lb-in. (0.9
Nm) and 9 lb-in. (1.02 Nm) of torque to the screw.
- Using the other removed screw, secure the negative (–)
DC source power cable lug to the –48 VDC terminal.
Tighten the screw until snug. Do not overtighten. Apply between 8
lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torque to the screw.
- Dress the power cables appropriately.
- Replace the clear plastic cover over the terminal block.
- Verify that the power cables do not block access
to router components or drape where people can trip on them.
- On J2320 and J2350 routers, use the power cable
tie as follows to relieve strain on the cable (see Figure 65 ):
- Wrap the loose end of the tie around the cable, and insert
it into the opening on the tie.
- Pull the end to tighten the tie.
To release the tie from the cable, press down the tab on the
tie and loosen it.
Figure 65: Connecting DC Power to the
J2350 Services Router

Figure 66: Connecting DC Power to the J4350 or J6350 Services Router

[