Table 34 and Table 35 provide the module names, software release information, slot and port numbers, maximum number allowed on a chassis, and sample interface names (where applicable) for the Avaya VoIP modules.
![]() |
Caution: Do not install a combination of PIMs in a single chassis that exceeds the maximum power and heat capacity of the chassis. If J-series power management is enabled, PIMs that exceed the maximum power and heat capacity remain offline when the chassis is powered on. |
On each J-series Services Router with Avaya VoIP, a single TGM550 Telephony Gateway Module (TGM) and at least one telephony interface module (TIM) is required. No more than four TIMs of any kind can be installed on a single chassis.
Table 34: J2320 and J2350 Avaya VoIP Module Summary
|
PIM |
Also Called |
Software Release for This PIM |
Slot and Port Numbering |
Maximum Number on a Chassis |
Sample Interface Name (type-pim/0/port) |
|---|---|---|---|---|---|
|
TGM550 Telephony Gateway Module |
|
JUNOS 8.4 and later |
|
One (required) If more than one TGM550 is installed, only the one in the lowest-numbered slot is enabled. For example, if TGM550s are installed in slots 2 and 3, only the one in slot 2 is enabled. |
vp-3/0/0 (See the interface naming conventions in the J-series Services Router Basic LAN and WAN Access Configuration Guide.) |
|
TIM508 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
|
One on J2320 Three on J2350 (See Planning for Power Management.) |
– |
|
TIM510 E1/T1 Telephony Interface Module |
|
JUNOS 8.4 and later |
|
Two |
– |
|
TIM514 Analog Telephony Interface Module |
|
JUNOS 8.4 and later |
|
Two |
– |
|
TIM516 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
|
One on J2320 Three on J2350 (See Planning for Power Management.) |
– |
|
TIM518 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
|
One on J2320 Three on J2350 (See Planning for Power Management.) |
– |
|
TIM521 BRI Telephony Interface Module |
|
JUNOS 8.4 and later |
|
Two |
– |
Table 35: J4350 and J6350 Avaya VoIP Module Summary
|
PIM |
Also Called |
Software Release for This PIM |
Slot and Port Numbering |
Maximum Number on a Chassis |
Sample Interface Name (type-pim/0/port) |
|---|---|---|---|---|---|
|
TGM550 Telephony Gateway Module |
|
JUNOS 8.2 and later |
Slots 1 through 6 |
One (required) If more than one TGM550 is installed, only the one in the lowest-numbered slot is enabled. For example, if TGM550s are installed in slots 2 and 3, only the one in slot 2 is enabled. |
vp-3/0/0 (See the interface naming conventions in the J-series Services Router Basic LAN and WAN Access Configuration Guide.) |
|
TIM508 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
Slots 1 through 6 |
Three (See Planning for Power Management.) |
– |
|
TIM510 E1/T1 Telephony Interface Module |
|
JUNOS 8.2 and later |
Slots 1 through 6 |
Two |
– |
|
TIM514 Analog Telephony Interface Module |
|
JUNOS 8.2 and later |
Slots 1 through 6 |
Four |
– |
|
TIM516 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
Slots 1 through 6 |
Three (See Planning for Power Management.) |
– |
|
TIM518 Analog Telephony Interface Module |
|
JUNOS 8.5 and later |
Slots 1 through 6 |
Three (See Planning for Power Management.) |
– |
|
TIM521 BRI Telephony Interface Module |
|
JUNOS 8.2 and later |
Slots 1 through 6 |
Two |
– |