Navigate to the Interfaces level
in the configuration hierarchy.
|
- In the J-Web interface, select Configuration>View
and Edit>Edit Configuration.
- Next to Interfaces, click Edit.
|
From the [edit] hierarchy level, enter
edit interfaces at-2/0/0
|
|
Create the new interface—for example, at-2/0/0.
|
- Next to Interface, click Add
new entry.
- In the Interface name box, type at-2/0/0.
- Click OK.
| |
| Configuring
Physical Properties |
|
Configure ATM virtual path identifier (VPI) options for the
interface—for example, at-2/0/0.
- ATM VPI—A number between 0 and 255—for example, 25.
- Operation, Maintenance, and Administration (OAM) F5 loopback
cell thresholds (“liveness”) on ATM virtual circuits.
The range is between 1 and 255, and the default
is 5 cells.
- Down count—Number of consecutive OAM loopback cells
an ATM virtual circuit must lose to be identified as unavailable—for
example, 200.
- Up count—Number of consecutive OAM loopback cells
an ATM virtual interface must receive to be identified as operational—for
example, 200.
- OAM period—Interval, in seconds, at which OAM cells
are transmitted on ATM virtual circuits—for example, 100. The range is between 1 and 900 seconds.
|
- In the Interface name box, select at-2/0/0.
- Next to Atm options, click Configure.
- Next to Vpi, click Add new entry.
- In the Vpi number box, type 25.
- Click OK.
- In the Actions box, click Edit.
- Next to Oam liveness, click Configure.
- In the Down count box, type 200.
- In the Up count box, type 200.
- Click OK.
- Next to Oam period, click Configure.
- From the Oam period choices list, select Oam period.
- In the Oam period box, type 100.
- Click OK until you return
to the Interface page.
|
- To configure the VPI value, enter
set atm-options vpi 25
- To configure OAM liveness values on a VPI, enter
set atm-options vpi 25 oam-liveness up-count 200 down-count
200
- To configure the OAM period, enter
set atm-options vpi 25 oam-period 100
|
|
Configure the type of DSL operating mode for the ATM-over-ADSL
interface—for example auto.
Annex A and Annex B support the following operating modes:
Annex A supports the following operating modes:
Annex B supports the following operating modes:
-
auto—Configures the ADSL interface to autonegotiate
settings with the DSLAM located at the central office. For Annex A,
the ADSL interface trains in either ANSI T1.413 Issue II
mode or ITU G.992.1 mode. For Annex B, the ADSL interface
trains in ITU G.992.1 mode.
-
itu-dmt—Configures the ADSL interface to
train in ITU G.992.1 mode.
-
adsl2plus—Configures the ADSL interface
to train in ITU G.992.5 mode. You can configure this mode only when
it is supported on the DSLAM.
-
itu-dmt-bis—Configures the ADSL interface
to train in ITU G.992.3 mode. You can configure this mode only when
it is supported on the DSLAM.
-
ansi-dmt—Configures the ADSL interface
to train in the ANSI T1.413 Issue II mode.
-
etsi—Configures the ADSL line to train
in the ETSI TS 101 388 V1.3.1 mode.
-
itu-annexb-ur2—Configures the ADSL line
to train in the G.992.1 Deutsche Telekom UR-2 mode.
-
itu-annexb-non-ur2—Configures the ADSL
line to train in the G.992.1 Non-UR-2 mode.
|
- Next to Dsl options, click Configure.
- From the Operating Mode list, select auto.
- Click OK.
|
Enter
set dsl-options operating-mode auto
|
|
Configure the encapsulation type—for example, ethernet-over-atm.
-
atm-pvc—ATM permanent virtual circuits
is the default encapsulation for ATM-over-ADSL interfaces.
For PPP over ATM (PPPoA) over ADSL interfaces, use this type
of encapsulation.
-
ethernet-over-atm—Ethernet over ATM encapsulation.
For PPP over Ethernet (PPPoE) over ATM-over-ADSL interfaces
that carry IPv4 traffic, use this type of encapsulation.
|
From the Encapsulation list, select ethernet-over-atm.
|
Enter
set encapsulation ethernet-over-atm
|
| Configuring
Logical Properties |
|
Add the logical interface.
Set a value from 0 and 16385—for example, 3.
Add other values if required by your network.
|
- Scroll down the page to Unit, and click Add new entry.
- In the Interface unit number box, type 3.
- Enter other values in the fields required by your
network.
|
Enter
set unit 3
|
|
Configure encapsulation for the ATM-for-ADSL logical unit—for
example, atm-nlpid.
The following encapsulations are supported on the ATM-over-ADSL
interfaces that use inet (IP) protocols only:
-
atm-vc-mux–Use ATM virtual circuit multiplex
encapsulation.
-
atm-nlpid–Use ATM network layer protocol
identifier (NLPID) encapsulation.
-
atm-cisco-nlpid–Use Cisco NLPID encapsulation.
-
ether-over-atm-llc–For interfaces that
carry IPv4 traffic, use Ethernet over LLC encapsulation. You cannot
configure multipoint interfaces if you use this type of encapsulation.
The following encapsulations are supported on the ATM-over-ADSL
for PPP-over-ATM (PPPoA) interfaces only. (For a sample PPPoA configuration,
see Verifying Interface Configuration.)
-
atm-ppp-llc— AAL5 logical link control
(LLC) encapsulation.
-
atm-ppp-vc-mux—Use AAL5 multiplex encapsulation.
Other encapsulation types supported on the ATM-over-ADSL interfaces:
-
ppp-over-ether-over-atm-llc—Use PPP over
Ethernet over ATM LLC encapsulation. When you use this encapsulation
type, you cannot configure the interface address. Instead you configure
the interface address on the PPP interface.
-
atm-snap—Use ATM subnetwork attachment
point (SNAP) encapsulation.
|
From the Encapsulation list, select atm-nlpid.
|
Enter
set unit 3 encapsulation atm-nlpid
|
|
Configure Operation, Maintenance, and Administration (OAM) options
for ATM virtual circuits:
- OAM F5 loopback cell thresholds (“liveness”)
on ATM virtual circuits. The range is between 1 and 255, and the default is 5 cells.
- Down count—Number of consecutive OAM loopback cells
an ATM virtual circuit must lose to be identified as unavailable—for
example, 200.
- Up count—Number of consecutive OAM loopback cells
an ATM virtual interface must receive to be identified as operational—for
example, 200.
- OAM period—Interval, in seconds, at which OAM cells
are transmitted on ATM virtual circuits—for example, 100. The range is between 1 and 900 seconds.
|
- Next to Oam liveness, click Configure.
- In the Down count box, type 200.
- In the Up count box, type 200.
- Click OK.
- Next to Oam period, click Configure.
- From the Oam period choices list, select Oam period.
- In the Oam period box, type 100.
- Click OK.
|
- To configure OAM liveness values for an ATM
virtual circuit, enter
set unit 3 oam-liveness up-count 200 down-count 200
- To configure the OAM period, enter
set unit 3 oam-period 100
|
|
Add the Family protocol type—for example, inet.
|
- In the Inet box, select Yes and click Configure.
- Enter the values in the fields required by your
network.
- Click OK.
|
Enter
set unit 3 family inet
Commands vary depending on the protocol type.
|
|
Configure ATM virtual channel identifier (VCI) options for the
interface.
- ATM VCI type—vci.
- ATM VCI value—A number between 0 and 4089—for example, 35— with VCIs 0 through
31 reserved.
|
- From the Vci Type list, select vci.
- In the Vci box, type 35.
- Click OK until you return
to the Interfaces page.
|
- To configure the VCI value, enter
set unit 3 vci 35
|