Display the details of DLSw circuits currently established after configuration in Configuring Basic DLSw (Required).
From the CLI, enter the show dlsw circuits detail command.
user@host> show dlsw circuits detail
Circuit ID: 9ad20498aa04
Local address: 22:22:00:00:00:06, LSAP: 04
Remote address: 44:44:00:00:00:06, DSAP: 04
Remote peer address: 18.255.18.2
Circuit state: Connected
Uptime: 00:09:02
Max BTU size: 1466
Circuit priority: 3
Statistics:
I-frames received : 0
I-frames sent : 0
Bytes in I-frames received : 0
Bytes in I-frames sent : 0
I frames rejected : 0
Bytes in I-frames rejected : 0
I-frames retransmitted : 0
Bytes in retransmitted I-frames : 0
Reject frames received : 0
Reject frames sent : 0
XID frames received : 2
XID frames sent : 2
In addition to the local and remote MAC addresses, the priority, the maximum basic transmission unit (BTU) size, and the statistics are displayed.
For a complete description of show dlsw circuits detail output, see the JUNOS System Basics and Services Command Reference.