Navigate to the Class of service level in the configuration
hierarchy.
|
- In the J-Web interface, select Configuration>View
and Edit>Edit Configuration.
- Next to Class of service, click Configure or Edit.
|
From the [edit] hierarchy level, enter
edit class-of-service
|
|
Configure the lower drop probability for normal, non-PLP traffic.
|
- Click Add new entry next to Drop
profiles.
- In the Profile name box, type the name of the drop profile—for
example, af-normal.
- Click Configure next to Interpolate.
- Click Add new entry next to Drop probability.
- In the Value box, type a number for the first drop point—for
example, 0.
- Click OK.
- Click Add new entry next to Drop probability
again.
- In the Value box, type a number for the next drop point—for
example, 100.
- Click OK.
|
Enter
edit drop-profiles af-normal interpolate
set drop-probability 0
set drop-probability 100
|
|
Configure a queue fill level for the lower non-PLP drop probability.
|
- Click Add new entry next to Fill
level.
- In the Value box, type a number for the first fill level—for
example, 95.
- Click OK.
- Click Add new entry next to Fill level.
- In the Value box, type a number for the next fill level—for
example, 100.
- Click OK three times.
|
Enter
set fill-level 95
set fill-level 100
|
|
Configure the higher drop probability for PLP traffic.
|
- Click Add new entry next to Drop
profiles.
- In the Profile name box, type the name of the drop profile—for
example, af-with-plp.
- Click Configure next to Interpolate.
- Click Add new entry next to Drop probability.
- In the Value box, type a number for the first drop point—for
example, 95.
- Click OK.
- Click Add new entry next to Drop probability.
- In the Value box, type a number for the next drop point—for
example, 100.
- Click OK.
|
From the [edit class of service] hierarchy level, enter
edit drop-profiles af-with-PLP interpolate
set drop-probability 95
set drop-probability 100
|
|
Configure a queue fill level for the higher PLP drop probability.
|
- Click Add new entry next to Fill
level.
- In the Value box, type a number for the first fill level—for
example, 80.
- Click OK.
- Click Add new entry next to Fill level.
- In the Value box, type a number for the next fill level—for
example, 95.
- Click OK.
|
Enter
set fill-level 80
set fill-level 95
|