Planning for Power Management

Before you install a chassis or add a new PIM to an existing chassis, verify that the combination of PIMs to be installed does not exceed the power and heat capacities for that model. Add the power and heat tokens required by each PIM, and compare them to the capacity of the chassis.

Caution: Do not install a combination of PIMs in a single chassis that exceeds the maximum power and heat capacity of the chassis. If J-series power management is enabled, PIMs that exceed the maximum power and heat capacity remain offline when the chassis is powered on.

To verify that the combination of PIMs to be installed in a chassis does not exceed the power and heat capacities for that model:

  1. Check Table 51 to determine the token values for power and heat for each PIM that you plan to install in the chassis.
  2. Add the power tokens and heat dissipation tokens for all PIM to be installed in the chassis.
  3. Verify that the total number of power tokens and the total number of heat dissipation tokens do not exceed the maximums permitted for your J-series chassis as specified in Table 52.

Table 51 shows the power consumption and heat dissipation, represented in non-dimensional tokens, assigned to each J-series PIM.

Table 51: J-series PIM Power Consumption and Heat Dissipation

Name Model Number PIM Abbreviation in JUNOS CLI Tokens
Power Heat

1-Port Gigabit Ethernet uPIM

JXU-SFP-S

1xSFP uPIM

8

8

6-Port Gigabit Ethernet uPIM

JXU-6GE-SFP-S

6xSFP uPIM

13

13

8-Port Gigabit Ethernet uPIM

JXU-8GE-TX-S

8xGE uPIM

21

27

16-Port Gigabit Ethernet uPIM

JXU-16GE-TX-S

16xGE uPIM

38

36

1-Port Copper Gigabit Ethernet ePIM

JXE-1GE-TX-S

1xGE Copper

6

7

1-Port SFP Gigabit Ethernet ePIM

JXE-1GE-SFP-S

1xGE SFP

4

4

Dual-Port Serial PIM

JX-2Serial-S

2xSerial

5

6

Dual-Port E1 PIM

JX-2E1-RJ48-S

2xE1

6

6

Dual-Port T1 PIM

JX-2T1-RJ48-S

2xT1

6

5

Dual-Port Channelized T1/E1/ISDN PRI PIM

JX-2CT1E1-RJ45-S

2xCT1E1 / PRI

6

5

E3 PIM (1 port)

JX-1E3-S

1xE3

7

7

T3 PIM (also known as DS3)

JX-1DS3-S

1xT3

7

7

Dual-Port Fast Ethernet PIM

JX-2FE-TX-S

2xFE

6

6

4-Port Fast Ethernet ePIM

JXE-4FE-TX-S

4xFE ePIM

9

9

4-Port ISDN BRI S/T PIM

JX-4BRI-S-S

4x BRI S/T

4

4

4-Port ISDN BRI U PIM

JX-4BRI-U-S

4x BRI U

4

6

ADSL 2/2+ Annex A PIM (1 port, for POTS)

JX-1ADSL-A-S

1x ADSL Annex A

16

16

ADSL 2/2+ Annex B PIM (1 port, for ISDN)

JX-1ADSL-B-S

1x ADSL Annex B

16

16

G.SHDSL PIM (2-port two-wire mode or 1-port four-wire mode)

JX-2SHDSL-S

2x SHDSL (ATM)

9

10

TGM550 Telephony Gateway Module

Avaya

1x TGM550

14

19

TIM510 E1/T1 Telephony Interface Module

Avaya

1x DS1 TIM510

6

6

TIM514 Analog Telephony Interface Module

Avaya

4x FXS, 4xFXO TIM514

4

13

TIM521 BRI Telephony Interface Module

Avaya

4x BRI TIM521

3

3

Table 52 lists the maximum power tokens and maximum heat tokens available for each model.

Table 52: Maximum Power and Heat Capacities of J-series Models

Model Power Capacity (tokens) Heat Capacity (tokens)

J2320

50

50

J2350

83

83

J4350

100

100

J6350

100

100