[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

Router Environmental Tolerances

Table 41 specifies the environmental conditions required for normal Services Router operation. In addition, the site must be as dust-free as possible. Dust can clog air intake vents, reducing cooling system efficiency. Check vents frequently, cleaning them as necessary.

Table 41: Router Environmental Tolerances

Description

Value

Altitude

No performance degradation to 10,000 ft (3048 m)

Relative humidity

Normal operation ensured in relative humidity range of 5% to 90%, noncondensing

Temperature

Normal operation ensured in temperature range of 32°F (0°C) to 104°F (40°C)

Non-operating storage temperature in shipping carton: –40°F (–40°C) to 158°F (70°C)

Seismic

Designed to meet Telcordia Technologies Zone 4 earthquake requirements

Maximum thermal output

J2300 chassis

  • Typical—270 BTU/hour (80 W)
  • Maximum—750 BTU/hour (220 W)

J4300 and J6300 chassis

  • Typical—510 BTU/hour (150 W)
  • Maximum—1190 BTU/hour (350 W)

[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]