J6350 Power System

The J6350 Services Router uses either AC or DC power. You can install one or two autosensing, load-sharing power supplies at the bottom rear of the chassis, as shown in Figure 3 or Figure 5. The power supplies distribute the different output voltages to the router components, depending on their voltage requirements. When two power supplies are installed and operational, they automatically share the electrical load.

For full redundancy, two power supplies are required. If a power supply stops functioning for any reason, the second power supply instantly begins providing all the power the router needs for normal functioning. It can provide full power indefinitely. Power supplies on the J6350 Services Router can be hot-swapped.

Each power supply has an LED located to the upper right of the power supply connector. Table 11 describes the power supply LED.

For information about site power preparations, see Power Guidelines, Requirements, and Specifications. For information about connecting the router to power and ground, see Connecting Power.

Power supplies on J6350 Services Routers are hot-removable and hot-insertable. You can remove and replace a redundant power supply without powering down the router or disrupting the routing functions. To avoid electrical injury, carefully follow the instructions in Replacing Power System Components.

You cannot mix DC and AC power supplies in the same chassis.

DC-powered Services Routers are intended for installation only in a restricted access location.