|
Navigate to the Interfaces level in the
configuration hierarchy.
|
- In the J-Web interface, select Configuration>Edit
Configuration>View and Edit.
- Next to Interfaces, click Edit.
|
From the [edit] hierarchy level, enter one of the following:
edit interfaces ct1-3/0/0
edit interfaces ce1-3/0/0
|
|
Create the new interface—for example, ct1-3/0/0 or ce1-3/0/0.
|
- Next to Interfaces, click Add new entry.
- In the Interface name box, type one of the following interface
names:
- Click OK.
|
|
Configure interface options:
|
- In the Interface table, under
Interface name, click the interface you are configuring:.
- From the Clocking list, select internal.
- In the Description box, type one of the following descriptions:
-
clear t1 interface
-
clear e1 interface
- Under Hold time:
Next to Down, type 500.
Next to Up, type 500.
- Under No partition, from the Interface type list, select
the type of interface:
- From the Scheduler type list, select Per
unit scheduler.
|
- Enter
set clocking internal
- Add a description:
- For T1 interfaces, enter set description clear t1 interface.
- For E1 interfaces, enter set description clear e1 interface.
- Enter
set hold-time down 500 up 500
- Specify a clear channel:
- For T1 interfaces, enter set no--partition interface-type
t1.
- For E1 interfaces, enter set no--partition interface-type
e1.
- Enter
set per-unit-scheduler
|
|
Configure T1 or E1 options:
- Bit error rate test (BERT) algorithm—for example, all ones
repeating.
- BERT error rate, a value from 0 through 7—for example, 5.
- BERT period, in seconds, a value from 1 through 240—for
example, 5.
- (T1 interfaces only) Line buildout, in feet for cables 655 ft
(200 m) or shorter—for example, 0-132—or in decibels for longer
cables.
- Framing mode:
- For T1 interfaces, either superframe or extended superframe (ESF)—for
example, ESF
- For E1 interfaces, G704, G704 without cyclic redundancy check
4 (CRC4), or G703 unframed—for example, G704.
- (T1 interfaces only) Line encoding method—for example, alternate
mark inversion (AMI).
- Loopback mode—for example, local.
|
- Next to T1 options or E1 options, click Configure.
- From the Bert algorithm list, select all-ones-repeating.
- In the Bert error rate box, type 5.
- In the Bert period box, type 5.
- For T1 interfaces only, from the Buildout list, select 0-132.
- From the Framing list:
- For T1 interfaces, select esf.
- For E1 interfaces, select g704.
- For T1 interfaces only, from the Line encoding list,
select ami
- From the Loopback list, select local.
- Click OK
|
- Enter
set bert-algorithm all-ones-repeating
- Enter
set bert-error-rate 5
- Enter
set bert-period 5
- For T1 interfaces only, enter
set buildout 0-132
- Set the framing mode:
- For T1 interfaces, enter set framing esf.
- For E1 interfaces, enter set framing g707.
- For T1 interfaces only, enter
set line encoding ami
- Enter
set loopback local
|
|
Configure trace options.
|
- Next to Traceoptions,
select the check box and click Configure.
- Next to Flag, click Add new entry.
- From the Flag name list, select all.
- Click OK until you return to the Interface
page.
|
Enter
set traceoptions flag all
|
|
Configure advanced options
For example, apply configuration settings from one or more groups except
the test group.
|
- Next to Advanced, click the expand (+) icon.
- Next to Apply groups except, click Add
new entry.
- In the Value box, type test.
- Click OK.
|
Enter
set interfaces apply-groups test
|