Navigate to the Interfaces level in the
configuration hierarchy.
|
- In the J-Web interface, select Configuration>Edit
Configuration>View and Edit.
- Next to Interfaces, click Edit.
|
From the [edit] hierarchy level, enter
edit interfaces interface-name
|
|
Select an E1 or T1 interface—for example, t1–1/0/0.
Set PPP as the type of encapsulation for the physical interface.
|
- Next to a T1 or E1 interface, click Edit.
- From the Encapsulation list, select ppp as
the encapsulation type.
- Next to Unit, click Add new entry.
- In the Interface unit number box, type 0.
|
- Enter
set encapsulation ppp
- Enter
edit unit 0
|
|
Add the link services interface, ls-0/0/0.0, to the physical
interface.
|
- In the Compression device box, enter ls-0/0/0.0.
- Click OK until you return to the Interfaces
page.
|
Enter
set compression-device ls-0/0/0.0
|
|
Add the link services interface, ls-0/0/0, to the Services Router.
|
- Next to Interface, click Add new entry.
- In the Interface name box, type ls-0/0/0.
- Click OK to return to the Interfaces
page.
- On the main Interface page, next to ls-0/0/0, click Edit.
- Next to Unit, click Add new entry.
- In the Interface unit number box, type 0.
|
From the [edit interfaces] hierarchy level, enter
edit interfaces ls-0/0/0 unit 0
|
|
Configure the link services interface, ls-0/0/0, properties.
F-max period—Maximum number of compressed
packets allowed between transmission of full headers. It has a range from 1 to 65535.
Maximum and Minimum—UDP
port values from 1 to 65536 reserve these ports for RTP
compression. CRTP is applied to network traffic on ports within this range.
This feature is applicable only to voice services interfaces.
|
- Next to Compression, select yes,
and then click Configure.
- Select RTP, and then click Configure.
- In the F-Max period box, type 2500.
- Select Port, then click Configure.
- In the Minimum value box, type 2000.
- In the Maximum value box, type 64009.
- Click OK.
|
Enter
set compression rtp f-max-period 2500 port minimum 2000 maximum
64009
|