[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Router Environmental
Tolerances
Table 39 specifies the environmental
conditions required for normal Services Router operation. In addition,
the site must be as dust-free as possible. Dust can clog air intake vents,
reducing cooling system efficiency. Check vents frequently, cleaning them
as necessary.
Table 39: Router Environmental
Tolerances
|
Description
|
Value
|
|
Altitude
|
No performance degradation to 10,000 ft (3048 m)
|
|
Relative humidity
|
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
|
|
Temperature
|
Normal operation ensured in temperature range of 32°F (0°C)
to 104°F (40°C)
Non-operating storage temperature in shipping carton: –40°F (–40°C)
to 158°F (70°C)
|
|
Seismic
|
Designed to meet Telcordia Technologies Zone 4 earthquake requirements
|
|
Maximum thermal output
|
J2300 chassis
- Typical—270 BTU/hour (80 W)
- Maximum—750 BTU/hour (220 W)
J4300 and J6300 chassis
- Typical—510 BTU/hour (150 W)
- Maximum—1190 BUT/hour (350 W)
|
[Contents]
[Prev]
[Next]
[Index]
[Report an Error]