Navigate to the Services>RPM>BGP level in the configuration
hierarchy.
|
- In the configuration editor hierarchy, select Services.
- Next to RPM, select the Yes check
box and click Configure.
- Next to BGP, click Configure.
|
From the top of the configuration hierarchy, enter
edit services rpm bgp
|
|
Specify a hexadecimal value (the range is between 1 and 2048 characters)
that you want to use for the data portion of the RPM probe—for example, ABCD123.
|
In the Data fill box, type ABCD123.
|
Enter
set data-fill ABCD123
|
|
Specify the data size of the RPM probe in bytes, a value from 0 through
65507—for example, 1024.
|
In the Data size box, type 1024.
|
Enter
set data-size 1024
|
|
Configure port 50000 as the TCP port to which the RPM probes are sent.
|
In the Destination port box, type 50000.
|
Enter
set destination-port 50000
|
|
Specify the number of probe results to be saved in the probe history—for
example, 25. The range is between 0 and 255, and
the default is 50.
|
In the History size box, type 25.
|
Enter
set history-size 25
|
|
Configure the probe count—for example, 5—and probe
interval—for example, 1.
- Probe count—Total number of RPM probes to be sent for each
test. The range is between 1 and 15 and the default is 1.
- Probe interval—Wait time (in seconds) between RPM probes.
The range is between 1 and 255, and the default is 3.
|
- In the Probe count box, type 5.
- In the Probe interval box, type 1.
|
Enter
set probe-count 5 probe-interval 1
|
|
Specify the type of probe to be sent as part of the test—tcp-ping.
Note:
If you do not specify the probe type the default ICMP probes are sent.
|
In the Probe type box, select tcp-ping.
|
Enter
set probe-type tcp-ping
|
|
Configure a value between 0 and 86400 seconds for
the interval between tests—for example, 60.
|
- In the Test interval box, type 60.
- Click OK.
|
Enter
set test-interval 60
|