Installing an AC Power Supply in a J6300 Router

To install an AC power supply in a J6300 Services Router (see Figure 67):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground. For more information about ESD, see Preventing Electrostatic Discharge Damage.
  2. Using both hands, slide the power supply into the chassis until you feel resistance.
  3. Firmly push the power supply into the chassis until it comes to a stop. Make sure that the power supply faceplate is flush with any adjacent power supply faceplate.
  4. Insert the appliance coupler end of a power cord into the appliance inlet on the power supply faceplate.
  5. Insert the power cord plug into an AC power source receptacle.

    Each power supply must be connected to a dedicated AC power feed. For information about connecting to AC power sources, see Connecting Power to the Services Router.

  6. Verify that the power cord does not block access to router components or drape where people might trip on it.
  7. Press and release the power button to power on the router. Verify that the POWER ON LED lights steadily after you press the power button.

Figure 67: Installing an AC Power Supply

Image g003565.gif