Navigate to the Forwarding options level in the
configuration hierarchy.
|
In the configuration editor hierarchy, select Forwarding
options.
|
From the top of the configuration hierarchy, enter edit forwarding-options.
|
|
Specify in bytes the maximum size of each packet to capture in each
file—for example, 500. The range is between 68 and 1500, and
the default is 68 bytes.
|
- From the Sampling or packet capture list, select Packet capture.
- Next to Packet capture, click Configure.
- In the Maximum capture size box, type 500.
|
Enter
set packet-capture maximum-capture-size 500
|
|
Specify the target filename for the packet capture file—for example, pcap-file.
For each physical interface, the interface name is automatically suffixed
to the filename—for example, pcap-file.fe-0.0.1.
|
In the Filename box, type pcap-file.
|
Enter
set packet-capture file filename pcap-file
|
|
Specify the maximum number of files to capture—for example, 100.
The range is between 2 and 10,000, and the default is 10 files.
|
In the Files box, type 100.
|
Enter
set packet-capture file files 100
|
|
Specify the maximum size of each file in bytes—for example, 1024.
The range is between 1,024 and 104,857,600, and the default is 512,000 bytes.
|
In the Size box, type 1024.
|
Enter
set packet-capture file size 1024
|
|
Specify if all users have permission to read the packet capture files.
|
- Next to World readable, select Yes.
- Click OK.
|
Enter
set packet-capture file world-readable
|