[Contents] [Prev] [Next] [Index] [Report an Error]

Installing a PIM Cable

To install a PIM cable:

  1. Have ready a length of the type of cable used by the PIM. For cable specifications, see Network Cable Specifications and Connector Pinouts.
  2. Insert the cable connector into the cable connector port on the PIM faceplate.
  3. Arrange the cable as necessary to prevent it from dislodging or developing stress points:
  4. Insert the other end of the cable into the destination port.
  5. Repeat the previous steps for any additional cables.
  6. If the PIM is offline (its status LED is steadily red), issue the following CLI command to bring the PIM online:
    user@host> request chassis pic fpc-slot pim-slot pic-slot 0 online

    For example, to bring the PIM in slot 4 online, enter the following command:


    user@host> request chassis pic fpc-slot 4 pic-slot 0 online

    For more information about the command, see the JUNOS System Basics and Services Command Reference.

  7. Verify that the PIM status LED shines steadily green to confirm that the PIM is online.

    You can also verify correct PIM functioning by issuing the show chassis fpc pic-status command described in the JUNOS System Basics and Services Command Reference.

    In the show chassis fpc pic-status command, the PIM slot number is reported as an FPC number and the PIM number (always 0) is reported as a PIC number.


[Contents] [Prev] [Next] [Index] [Report an Error]