Navigate to the Services>RPM level in the configuration
hierarchy.
|
- In the configuration editor hierarchy, select Services.
- Select the Yes check box.
- Click Edit.
|
From the top of the configuration hierarchy, enter
edit services rpm
|
|
Set the maximum number of concurrent probes allowed on the system to 10.
|
In the Probe limit box, type 10.
|
Enter
set probe-limit 10
|
|
Navigate to the Services>RPM>Probe>CustomerA> Test>Icmp-test level
in the configuration hierarchy.
|
- In the configuration editor hierarchy, select Services.
- Select the Yes check box.
- Click Edit.
- In the Probe box, click icmp-test.
|
From the top of the configuration hierarchy, enter
edit services rpm probe customerA test icmp-test
|
|
Set the time between probe transmissions to 30 seconds.
|
In the Probe interval box, type 15.
|
Enter
set probe-interval 15
|
|
Set the number of probes within a test to 10.
|
In the Probe count box, type 10.
|
Enter
set probe-count 10
|
|
Set the source address for each probe packet to 192.168.2.9.
If you do not explicitly configure a source address, the address on
the outgoing interface through which the probe is sent is used as the source
address.
|
In the Source address box, type 192.168.2.9.
|
Enter
set source-address 192.168.2.9
|