To configure interface alarms on a Services Router, you must select the network interface on which to apply an alarm and the condition you to trigger the alarm. For a list of conditions, see Interface Alarm Conditions.
To configure interface alarms:
Table 42: Configuring Interface Alarms
|
Navigate to the Alarm level in the configuration hierarchy. |
In the configuration editor hierarchy, select Chassis>Alarm. |
From the top of the configuration hierarchy, enter edit chassis alarm |
|
Configure the system to generate a red interface alarm when a Yellow alarm is detected on a T1 (DS1) link. |
|
Enter set ds1 ylw red |
|
Configure the system to generate a red interface alarm when a link down failure is detected on a Fast Ethernet link. |
|
Enter set ethernet link–down red |
|
Configure the system to generate the following interface alarms on a serial link:
|
|
|
|
Configure the system to generate the following interface alarms on a T3 link:
|
|
|
|
Configure the system to display active system alarms whenever a user with the login class admin logs in to the router. |
|
|