Checking Active Alarms
The alarm information includes alarm type, alarm severity, and a brief
description for each active alarm on the Services Router. To view the active
alarms, select Alarms in the J-Web interface, or enter the following
CLI show commands:
-
show chassis alarms
-
show system alarms
 |
If a Services Router has active
alarms and you have not displayed the View Alarms page, Alarms in
the task bar appears in red. After you view the alarms, Alarms returns
to grey. If new alarms become active, Alarms is red until
you again display the View Alarms page.
|
Figure 10 shows the View Alarms
summary page. Click an alarm in the list of active alarms to display a detailed
alarm message.
Figure 10: J-Web View Alarms Summary Page

Table 42 summarizes the output fields
on the alarms page.
Table 42: Summary
of Key Alarm Output Fields
|
Field
|
Values
|
Additional Information
|
| Alarm Summary
|
|
New?
|
Viewed status of the alarm—either Yes (a new alarm) or No (a previously
viewed alarm).
|
After you have once displayed the View Alarms page, any new alarms that
appear on the page during the same J-Web session are identified
as previously viewed.
|
|
Received at
|
Date and time when the alarm condition was detected.
|
|
|
Severity
|
Alarm severity—either major (red) or minor (yellow).
|
A major (red) alarm condition requires immediate action. A minor (yellow)
condition requires monitoring or maintenance.
|
|
Subject
|
Brief synopsis of the alarm.
|
Clicking the alarm subject displays a detailed alarm message.
|
| Detailed
Alarm Message |
|
Received at
|
Date and time when the failure was detected.
|
|
|
Severity
|
Alarm severity—either major (red) or minor (yellow).
|
A major (red) alarm condition requires immediate action. A minor
(yellow) condition requires monitoring or maintenance.
|
|
Alarm Type
|
Category of the alarm:
- Chassis—Indicates an alarm condition on the chassis (typically
an environmental alarm such as temperature)
- Configuration—Indicates that no rescue configuration is
set
- ETHER—Indicates an alarm condition on a Fast Ethernet interface
- DS3—Indicates an alarm condition on a DS3 interface
- License—Indicates a software license infringement
- Serial—Indicates an alarm condition on a serial interface
- Services—Indicates an alarm condition on the services module
|
|