interval (Health Monitor)
Syntax
interval seconds;
Hierarchy Level
[edit snmp health-monitor]
Description
Configure the interval between sampling of the object being monitored by the health monitor.
Options
seconds—Time between samples, in seconds.
Range: 1 through 2147483647 seconds
Default: 300 seconds
Required Privilege Level
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 14.1X53-D20.