show chassis fpc
Sintaxis
show chassis fpc <detail <slot>> | <pic-status <slot>> | <pfe-instance <pfe-id>> all
Sintaxis (conmutadores de la serie EX, enrutadores de la serie PTX, enrutadores de la serie universal ACX y ACX7509)
show chassis fpc <detail <fpc-slot>> | <pic-status <fpc-slot>> <fpc-slot> | <pfe <pfe-id>>
Sintaxis (enrutadores serie MX, conmutadores serie EX y serie PTX)
show chassis fpc < <slot>> | <pic-status <slot>> <all-members> <local> <member member-id>
Sintaxis (PTX10008 y PTX10001-36MR)
show chassis fpc <slot> | <pic-status <slot>> | <pfe-instance <pfe-id>> all
Sintaxis (plataformas de enrutamiento universal MX104, MX204, MX2010, MX2020, MX10003 y MX2008)
show chassis fpc <slot> detail | <detail <slot>> | <pic-status <slot>> <fpc-slot>
Sintaxis (MX304)
show chassis fpc <fpc-slot> <detail> <errors> <global-pfe-id> mic-status <fpc-slot> pic-status <fpc-slot>
Sintaxis (MX10008 plataformas de enrutamiento universal)
show chassis fpc <detail> <errors> <fpc-slot> pic-status <fpc-slot>
Sintaxis (MX10004)
show chassis fpc <fpc-slot> <detail> <errors> <global-pfe-id> pic-status <fpc-slot>
Sintaxis (serie QFX)
show chassis fpc <detail> <interconnect-device name <fpc-slot fpc-slot>> <node-device name>
Sintaxis (serie OCX)
show chassis fpc <detail>
Sintaxis (serie SRX)
show chassis fpc <fpc-slot> detail <fpc-slot> | <node (node-id | local |primary)>> pic-status <fpc-slot | <node (node-id | local |primary)>>
Sintaxis (Junos OS evolucionado)
show chassis fpc <fpc-slot> <detail | pic-status | <pfe-instance <pfe-id>> | errors> all
Descripción
Muestra información de estado sobre los concentradores PIC flexibles (FPC) y PIC instalados.
Opciones
none | Muestra información de estado de todos los FPC.
Nota:
En los conmutadores EX8200, las tarjetas de línea inicializan el motor de reenvío de paquetes durante el inicio. Si se produce un error durante la inicialización del hardware, las FPC con piezas de hardware defectuosas se apagan después de transferir la información de depuración al motor de enrutamiento. El motor de enrutamiento marca la FPC sin conexión, registra el error Vea el siguiente resultado de ejemplo: user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 1 Empty 2 Empty 3 Empty 4 Offline ---Configured power off--- 5 Offline ---Hard FPC error--- 6 Empty 7 Online 26 4 0 1024 0 32 error: communication failure with /fpc8/hwdfpc/ La siguiente salida de ejemplo muestra la alarma generada para los FPC con errores: user@host> show chassis alarms 4 alarms currently active Alarm time Class Description 2011-03-24 00:52:51 UTC Major FPC 5 Hard errors 2011-03-24 00:52:31 UTC Major Fan Tray Failure 2011-03-24 00:52:31 UTC Major Fan Tray Failure 2011-03-24 00:51:26 UTC Minor Loss of communication with Backup RE |
detail | (Opcional) Muestra información detallada del estado de todas las FPC o de la FPC de la ranura especificada (consulte |
all-members | (Solo enrutadores serie MX, conmutadores serie EX, PTX10016) (Opcional) Muestra información de estado de todas las FPC de todos los miembros de la configuración del chasis virtual. |
interconnect-device name | (Solo sistemas QFabric) (Opcional) Muestra información de estado de todas las FPC del dispositivo de interconexión. |
fpc-slot | (Opcional) Número de ranura FPC:
|
interconnect-device name |
(Solo sistemas QFabric) (Opcional) Muestra información de estado de todas las FPC del dispositivo de interconexión. |
local |
(Solo enrutadores serie MX y conmutadores serie EX) (Opcional) Muestra información de estado de todas las FPC en el miembro local de Virtual Chassis. |
member member-id |
(Solo enrutadores serie MX y conmutadores serie EX) (Opcional) Muestra información de estado para todos los FPC en el miembro especificado de la configuración del chasis virtual. Reemplazar |
node-device name |
(Solo sistemas QFabric) (Opcional) Muestra información de estado para cada dispositivo de nodo. Cada dispositivo de nodo es equivalente a un FPC. |
mic-status |
(Solo dispositivos MX304) (Opcional) Mostrar tarjetas de interfaz modular instaladas en FPC. |
pic-status |
(Opcional) Mostrar información de estado para todas las PIC o para el PIC en la ranura especificada (consulte
Nota:
Cuando hay un error ECC de doble bit en la memoria de un procesador de red, el MIC de emulación de circuito OC3/STM1 canalizado (multivelocidad) con SFP o MIC de emulación de circuito E1/T1 canalizado se cambia al estado sin conexión. user@host> show chassis fpc pic-status Slot 1 Online MPC Type 2 3D Q PIC 0 Offline 1xCOC12/4xCOC3 CH-CE- ECC error detected |
pfe-instance |
|
Nivel de privilegio requerido
vista
Campos de salida
En la tabla 1 se enumeran los campos de salida del show chassis fpc
comando. Los campos de salida se enumeran en el orden aproximado en que aparecen.
Nombre del campo |
Descripción del campo |
Nivel de salida |
---|---|---|
|
Número de ranura y estado. El estado puede ser una de las siguientes condiciones:
|
Todos los niveles |
|
Número de ranura. |
Todos los niveles |
|
Temperatura del aire que pasa por el FPC, en grados Celsius o en Celsius y Fahrenheit. |
Todos los niveles Todos los niveles |
|
En los enrutadores de transporte de paquetes de la serie PTX, los detalles de temperatura se proporcionan en grados Celsius y Fahrenheit. El resultado incluye:
|
|
|
Porcentaje total de CPU utilizado por el procesador del FPC. |
Todos los niveles |
|
Del total de CPU que utiliza el procesador del FPC, el porcentaje que se utiliza para las interrupciones. |
ninguna especificada |
Nota:
Solo se admite en MX240, MX480, MX960, MX2010, MX2020 y MX2008. |
Información sobre el uso de CPU del motor de enrutamiento en el último 1 minuto. |
ninguna especificada |
Nota:
Solo se admite en MX240, MX480, MX960, MX2010, MX2020 y MX2008. |
Información sobre el uso de CPU del motor de enrutamiento en los últimos 5 minutos. |
ninguna especificada |
Nota:
Solo se admite en MX240, MX480, MX960, MX2010, MX2020 y MX2008. |
Información sobre el uso de CPU del motor de enrutamiento en los últimos 15 minutos. |
ninguna especificada |
|
DRAM total, en megabytes, disponible para el procesador del FPC. |
ninguna especificada |
|
Porcentaje de espacio de almacenamiento dinámico (memoria dinámica) utilizado por el procesador del FPC. Si este número supera el 80 por ciento, puede haber un problema de software (pérdida de memoria).
Nota:
En los enrutadores serie MX y conmutadores serie EX en un entorno perimetral de banda ancha, los niveles de utilización del montón superiores al 70 % pueden afectar a la ISSU unificada, la estabilidad del enrutador o la capacidad de escalado. |
ninguna especificada |
|
Porcentaje de espacio de búfer utilizado por el procesador de la FPC para almacenar mensajes internos en búfer. |
ninguna especificada |
|
Cantidad de DRAM disponible para la CPU del FPC. |
|
|
Cantidad de memoria dinámica de acceso aleatorio (RLDRAM) de latencia reducida disponible para la CPU FPC. |
|
|
Cantidad de memoria de acceso aleatorio dinámico (DDR DRAM) de doble velocidad de datos disponible para la CPU FPC. |
|
|
Cantidad de RAM estática (SRAM) utilizada por la CPU del FPC. |
|
|
Cantidad total de memoria utilizada para almacenar paquetes y notificaciones. |
|
|
Número de versión, fabricante y número de pieza del gestor de E/S. |
|
|
Hora en que el motor de enrutamiento detectó que se estaba ejecutando la FPC. |
|
|
Cuánto tiempo ha estado conectado el motor de enrutamiento a la FPC y, por lo tanto, cuánto tiempo ha estado funcionando y funcionando la FPC. |
|
|
|
ninguna especificada |
PFE-Instance (PTX10008 y PTX10001-36MR) |
El identificador de instancia de PFE para la FPC específica. |
|
PFE-State (PTX10008 y PTX10001-36MR) |
El estado de PFE, Los posibles PFE-Estados son: EN LÍNEA: PFE está en línea. Apagado configurado: PFE Desconectado a través de la configuración. Desconectado por CLI: PFE se desconecta mediante el comando request en la CLI. Desconectado por CmError:PFE desconectado a través de la acción CM-Error. Transición sin conexión: Estado durante la transición de PFE. Culpa: Si el sistema toma la acción disable-pfe cmerror en errores mayores/fatales. |
|
GNF (división de nodos) |
Identificador GNF asociado a cada tarjeta de línea.
|
Todos los niveles |
|
Estado del acelerador de rendimiento de temperatura asociado con un ID FPC y PFE: "Habilitado" o "Deshabilitado". Esta función está habilitada de forma predeterminada en todas las instancias de PFE. |
|
|
Estado de reducción de voltaje de temperatura asociado con un ID de FPC y PFE: "Habilitado" o "Deshabilitado". Esta función está habilitada de forma predeterminada en todas las instancias de PFE. |
|
ZFP | Todas las instancias de PFE o número único de PFE (0 a 3) | pfe pfe_id |
PFE-Instance |
|
ninguna especificada |
|
Estado de PFE. (Habilitado o deshabilitado) | Todos los niveles |
PPFE-ID |
Según el ID de PFE. |
|
Salida de muestra (Junos OS)
- mostrar fpc del chasis (plataforma de enrutamiento universal de MX10004)
- mostrar FPC del chasis (conmutador EX6210)
- mostrar detalles de fpc del chasis (enrutadores de la serie M)
- mostrar detalles de fpc del chasis (MX150)
- mostrar fpc del chasis (enrutador MX104)
- mostrar detalles de FPC del chasis (enrutador MX104)
- mostrar el estado de la imagen FPC del chasis (enrutador MX104)
- mostrar fpc del chasis (enrutador MX240)
- mostrar detalles de FPC del chasis (conmutador EX9200)
- mostrar fpc del chasis (enrutador MX480)
- mostrar FPC del chasis (enrutador MX480 con CFP de 100 Gigabit Ethernet)
- mostrar el estado de la PIC FPC del chasis (enrutador MX480 con CFP de 100 Gigabit Ethernet)
- mostrar el estado de la imagen FPC del chasis (conmutador de la serie EX)
- mostrar fpc del chasis (enrutador MX960 con MPC5EQ)
- mostrar fpc del chasis (MX240, MX480, MX960 con tarjeta de línea modular de servicios de aplicación)
- Mostrar FPC del chasis (plataformas de enrutamiento universal MX240, MX480, MX960, MX2010, MX2020 y MX2008 con administración dinámica de energía)
- mostrar FPC del chasis (enrutador MX2010 con derivación de concesión de estructura habilitada)
- mostrar FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura deshabilitada)
- mostrar el estado de la imagen FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura habilitada)
- mostrar el estado de la imagen FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura deshabilitada)
- mostrar fpc del chasis (enrutadores MX2020)
- mostrar fpc del chasis (enrutador MX10003)
- mostrar detalles de FPC del chasis (enrutador MX10003)
- mostrar fpc del chasis <ranura FPC> (enrutador MX10003)
- mostrar FPC del chasis (enrutador MX204)
- mostrar detalles de FPC del chasis (enrutador MX204)
- mostrar FPC del chasis <ranura FPC> (enrutador MX204)
- mostrar fpc del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
- mostrar detalles de FPC del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
- mostrar el estado de la imagen FPC del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
- mostrar detalles de FPC del chasis (enrutadores de la serie MX)
- mostrar detalles de fpc del chasis (conmutadores de la serie EX)
- mostrar detalles de FPC del chasis (conmutadores EX9251)
- mostrar detalles de FPC del chasis (conmutadores EX9253)
- mostrar fpc del chasis (hardware no compatible)
- Mostrar detalles de FPC del chasis (hardware no compatible)
- mostrar el estado de la PIC de FPC del chasis
- mostrar el estado de la imagen FPC del chasis (enrutadores de la serie M)
- mostrar el estado de la imagen FPC del chasis (enrutadores MX240, MX480 y MX960 con tarjeta de línea modular de servicios de aplicación)
- mostrar FPC del chasis <ranura FPC> (conmutador de la serie EX)
- mostrar fpc del chasis (enrutador MX10008 con MX10K-LC9600 y SFB)
- mostrar fpc del chasis (series QFX y OCX)
- mostrar detalles de FPC del chasis (conmutadores QFX3500)
- mostrar el estado de la imagen FPC del chasis (conmutadores QFX3500)
- mostrar dispositivo de interconexión FPC del chasis (sistema QFabric)
- mostrar dispositivo de interconexión FPC del chasis (sistema QFabric)
- mostrar detalles del dispositivo de interconexión FPC del chasis (sistema QFabric)
- mostrar el dispositivo de interconexión de estado PIC FPC del chasis (sistema QFabric)
- mostrar nodo de estado FPC del chasis (sistema QFabric)
- Mostrar FPC del chasis (PTX10008)
- mostrar todas las instancias de PFE de FPC del chasis (enrutador PTX10008 y PTX10001-36MR)
- Mostrar detalles de FPC del chasis (PTX10008)
- mostrar fpc del chasis (enrutador PTX10016)
- mostrar detalles de FPC del chasis (enrutador PTX10016)
- mostrar FPC 1 del chasis (enrutadores MX con hoja Servicios multimedia [MSB])
- mostrar detalles del FPC 1 del chasis (enrutadores MX con blade Servicios multimedia [MSB])
- mostrar detalle de fpc del chasis (MX304)
- mostrar el estado del micrófono FPC del chasis (MX304 con LMIC)
mostrar fpc del chasis (plataforma de enrutamiento universal de MX10004)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Empty 1 Online 25 2 0 2 2 2 32768 33 2 2 Online 30 20 0 21 21 21 3168 9 22 3 Empty
mostrar FPC del chasis (conmutador EX6210)
user@switch> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 1 Online 7 5 0 1024 0 32 2 Empty 3 Empty 4 Online 25 17 2 2048 0 30 5 Online 25 3 0 2048 0 24 6 Online 6 5 0 1024 0 32 7 Empty 8 Empty 9 Online 8 7 0 1024 0 32
mostrar detalles de fpc del chasis (enrutadores de la serie M)
user@host> show chassis fpc detail 1 Slot 1 information: State Online Temperature 48 degrees C Total CPU DRAM 32 MB Total SRAM 4 MB Total SDRAM 256 MB I/O Manager ASICs information Version 2.0, Foundry IBM, Part number 0 I/O Manager ASICs information Version 2.0, Foundry IBM, Part number 0 Start time 2000-02-08 02:18:49 UTC Uptime 14 hours, 41 minutes, 41 seconds
mostrar detalles de fpc del chasis (MX150)
user@host> show chassis fpc detail Slot 0 information: State Online Temperature 42 degrees C / 107 degrees F Total CPU DRAM 2048 MB Total RLDRAM 10 MB Total DDR DRAM 0 MB Start time 2017-04-04 04:44:04 PDT Uptime 7 days, 19 hours, 45 minutes, 50 seconds
mostrar fpc del chasis (enrutador MX104)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 32 15 5 2048 22 13 1 Online 32 15 5 2048 22 13 2 Online 32 15 5 2048 22 13
mostrar detalles de FPC del chasis (enrutador MX104)
user@host> show chassis fpc detail Slot 0 information: State Online Temperature 32 (C) Total CPU DRAM 2048 MB Total SRAM 403 MB Total SDRAM 1316 MB Start time 2013-05-23 14:39:18 IST Uptime 1 hour, 20 minutes, 22 seconds Slot 1 information: State Online Temperature 32 (C) Total CPU DRAM 2048 MB Total SRAM 403 MB Total SDRAM 1316 MB Start time 2013-05-23 14:39:18 IST Uptime 1 hour, 20 minutes, 22 seconds Slot 2 information: State Online Temperature 32 (C) Total CPU DRAM 2048 MB Total SRAM 403 MB Total SDRAM 1316 MB Start time 2013-05-23 14:39:18 IST Uptime 1 hour, 20 minutes, 22 seconds
mostrar el estado de la imagen FPC del chasis (enrutador MX104)
user@host> show chassis fpc pic-status Slot 0 Online Slot 1 Online PIC 0 Online 10x 1GE(LAN) -E SFP PIC 1 Online 10x 1GE(LAN) -E SFP Slot 2 Online PIC 0 Online 4x 10GE(LAN) SFP+
mostrar fpc del chasis (enrutador MX240)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 1 Online 34 6 0 1024 18 30 2 Online 33 9 0 1024 24 30
Si instaló una tarjeta de control de conmutador (SCB1) en lugar de una tarjeta de línea (DPC0) en la ranura multifunción del MX240, el show chassis fpc
resultado muestra la ranura 0
vacía.
mostrar detalles de FPC del chasis (conmutador EX9200)
user@switch> show chassis fpc detail Slot 2 information: State Online Temperature 37 Total CPU DRAM 2048 MB Total RLDRAM 331 MB Total DDR DRAM 1536 MB Start time: 2014-03-12 15:35:28 UTC Uptime: 1 hour, 4 minutes, 29 seconds Max Power Consumption 239 Watts Slot 3 information: State Online Temperature 39 Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 6656 MB Start time: 2014-03-12 15:00:18 UTC Uptime: 1 hour, 39 minutes, 39 seconds Max Power Consumption 520 Watts
mostrar fpc del chasis (enrutador MX480)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 1 0 1 2 3 1024 4 56 1 Online 1 0 2 2 3 1024 4 56
mostrar FPC del chasis (enrutador MX480 con CFP de 100 Gigabit Ethernet)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 33 4 0 2048 10 13 1 Online 36 7 0 2048 16 13 2 Online 29 6 0 1024 27 29 3 Online 33 0 0 0 0 0 4 Online 36 7 0 2048 19 13 5 Online 34 31 11 2048 14 13
mostrar el estado de la PIC FPC del chasis (enrutador MX480 con CFP de 100 Gigabit Ethernet)
user@host> show chassis fpc pic-status Slot 1 Online MPC Type 3 PIC 2 Online 1X100GE CFP Slot 2 Online DPCE 40x 1GE R EQ PIC 0 Online 10x 1GE(LAN) EQ PIC 1 Online 10x 1GE(LAN) EQ PIC 2 Online 10x 1GE(LAN) EQ PIC 3 Online 10x 1GE(LAN) EQ Slot 3 Online MPC Type 3 PIC 0 Online 1X100GE CFP PIC 2 Online 1X100GE CFP Slot 4 Online MPC Type 3 PIC 0 Online 1X100GE CFP PIC 2 Online 1X100GE CFP Slot 5 Online MPC Type 2 3D EQ PIC 0 Online 2x 10GE XFP PIC 1 Online 2x 10GE XFP PIC 2 Online 10x 1GE(LAN) SFP PIC 3 Online 10x 1GE(LAN) SFP
mostrar el estado de la imagen FPC del chasis (conmutador de la serie EX)
user@host> show chassis fpc pic-status Slot 1 Online EX9200 32x10G SFP PIC 0 Online 8X10GE SFPP PIC 1 Online 8X10GE SFPP PIC 2 Online 8X10GE SFPP PIC 3 Online 8X10GE SFPP Slot 2 Online EX9200 32x10G SFP PIC 0 Online 8X10GE SFPP PIC 1 Online 8X10GE SFPP PIC 2 Online 8X10GE SFPP PIC 3 Online 8X10GE SFPP
mostrar fpc del chasis (enrutador MX960 con MPC5EQ)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 38 16 0 3584 7 13 1 Online 31 15 0 2048 17 13 2 Empty 3 Online 31 14 0 2048 20 13 4 Online 34 16 0 3584 7 13 5 Online 34 16 0 3584 7 13 6 Empty 7 Online 32 9 0 2048 18 14 8 Online 36 19 0 3584 7 13 9 Online 31 9 0 2048 13 13 10 Online 35 14 0 3584 7 13 11 Online 33 11 0 2048 18 14
mostrar fpc del chasis (MX240, MX480, MX960 con tarjeta de línea modular de servicios de aplicación)
user@host> show chassis fpc 1 detail Slot 1 information: State Online Temperature 34 Total CPU DRAM 3072 MB Total RLDRAM 259 MB Total DDR DRAM 4864 MB Start time: 2012-06-19 10:51:43 PDT Uptime: 16 minutes, 48 seconds Max Power Consumption 550 Watts
Mostrar FPC del chasis (plataformas de enrutamiento universal MX240, MX480, MX960, MX2010, MX2020 y MX2008 con administración dinámica de energía)
user@host> show chassis fpc 2 detail Slot 2 information: State Online Temperature 37 Total CPU DRAM 3584 MB Total XR2 275 MB Total DDR DRAM 20352 MB Start time: 2014-07-18 02:51:23 PDT Uptime: 5 minutes, 19 seconds Max MPC Base Power Consumption 485 Watts Max MIC0 Power Consumption 50 Watts Max MIC1 Power Consumption 50 Watts Max MPC Total Power Consumption 585 Watts
mostrar FPC del chasis (enrutador MX2010 con derivación de concesión de estructura habilitada)
A continuación se muestra el resultado del comando en un enrutador MX2010 con placa de estructura de conmutación (SFB), donde la omisión de concesión de show chassis fpc
estructura está habilitada de forma predeterminada. Todas las MPC se encienden.
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 34 20 0 2048 9 14 1 Offline 33 22 0 2048 9 14 2 Online 33 17 0 2048 9 14 3 Offline 34 25 0 2048 9 14 4 Online 32 27 0 2048 9 14 5 Offline 32 26 0 2048 9 14 6 Empty 7 Empty 8 Empty 9 Empty
mostrar FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura deshabilitada)
A continuación se muestra el resultado del comando en un enrutador MX2010 con placa de estructura de conmutación (SFB), donde se deshabilitó la show chassis fpc
omisión de concesión de estructura. MPC1 (MX-MPC1-3D), MPC2 (MX-MPC2-3D) y MPC de 10 Gigabit Ethernet de 16 puertos (MPC-3D-16XGE-SFP) no se encienden después de deshabilitar la omisión de concesión de estructura y reiniciar el enrutador. Además, se generan alarmas de configuración incorrecta de FPC.
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 34 20 0 2048 9 14 1 Offline ---FPC misconfiguration--- 2 Online 33 17 0 2048 9 14 3 Offline ---FPC misconfiguration--- 4 Online 32 27 0 2048 9 14 5 Offline ---FPC misconfiguration--- 6 Empty 7 Empty 8 Empty 9 Empty
mostrar el estado de la imagen FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura habilitada)
A continuación se muestra el resultado del comando en un enrutador MX2010 con placa de estructura de conmutación (SFB), donde la omisión de concesión de show chassis fpc pic-status
estructura se ha habilitado de forma predeterminada. Todas las MPC se encienden.
user@host> show chassis fpc pic-status Slot 0 Present MPCE Type 3 3D Slot 1 Present MPC Type 2 3D EQ Slot 2 Present MPCE Type 3 3D Slot 3 Present MPC 3D 16x 10GE Slot 4 Present MPCE Type 3 3D Slot 5 Present MPCE Type 1 3D Q
mostrar el estado de la imagen FPC del chasis (enrutador MX2010 con la omisión de concesión de estructura deshabilitada)
A continuación se muestra el resultado del comando en un enrutador MX2010 con placa de estructura de conmutación (SFB), donde se deshabilitó la show chassis fpc pic-status
omisión de concesión de estructura. MPC1 (MX-MPC1-3D), MPC2 (MX-MPC2-3D) y MPC de 10 Gigabit Ethernet de 16 puertos (MPC-3D-16XGE-SFP) no se encienden después de deshabilitar el modo de omisión de concesión de estructura y reiniciar el enrutador.
user@host> show chassis fpc pic-status Slot 0 Present MPCE Type 3 3D Slot 1 Offline MPC Type 2 3D EQ Slot 2 Present MPCE Type 3 3D Slot 3 Offline MPC 3D 16x 10GE Slot 4 Present MPCE Type 3 3D Slot 5 Offline MPCE Type 1 3D Q
mostrar fpc del chasis (enrutadores MX2020)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 10 12 0 2048 18 13 1 Online 8 9 0 2048 18 13 2 Online 7 9 0 2048 18 13 3 Online 8 10 0 2048 18 13 4 Online 9 10 0 2048 18 13 5 Online 8 9 0 2048 18 13 6 Online 8 10 0 2048 18 13 7 Online 9 9 0 2048 18 13 8 Online 9 10 0 2048 18 13 9 Online 10 9 0 2048 18 13 10 Online 16 8 0 2048 18 13 11 Online 11 10 0 2048 18 13 12 Online 10 10 0 2048 18 13 13 Online 11 9 0 2048 18 13 14 Online 12 10 0 2048 18 13 15 Online 13 9 0 2048 18 13 16 Online 13 9 0 2048 18 13 17 Online 12 9 0 2048 18 13 18 Online 12 8 0 2048 18 13 19 Online 14 10 0 2048 18 13
mostrar fpc del chasis (enrutador MX10003)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 59 25 0 25 24 23 3136 12 11 1 Online 62 29 0 26 24 23 3136 12 11
mostrar detalles de FPC del chasis (enrutador MX10003)
user@host> show chassis fpc detail Slot 0 information: State Online Total CPU DRAM 3136 MB Total RLDRAM 771 MB Total DDR DRAM 18432 MB Temperature 60 degrees C / 140 degrees F Start time 2017-07-19 20:49:58 PDT Uptime 2 hours, 29 minutes, 22 seconds Max MPC base power consumption 910 Watts Max MIC1 power consumption 95 Watts Max MPC total power consumption 1005 Watts Slot 1 information: State Online Total CPU DRAM 3136 MB Total RLDRAM 771 MB Total DDR DRAM 18432 MB Temperature 63 degrees C / 145 degrees F Start time 2017-07-19 20:48:01 PDT Uptime 2 hours, 31 minutes, 19 seconds Max MPC base power consumption 910 Watts Max MIC1 power consumption 155 Watts Max MPC total power consumption 1065 Watts
mostrar fpc del chasis <ranura FPC> (enrutador MX10003)
user@host> show chassis fpc 0 Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 49 26 0 22 22 23 3136 12 11
mostrar FPC del chasis (enrutador MX204)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online Absent 8 0 8 8 8 3136 8 8
mostrar detalles de FPC del chasis (enrutador MX204)
user@host> show chassis fpc detail Slot 0 information: State Online Total CPU DRAM 3136 MB Total RLDRAM 257 MB Total DDR DRAM 4096 MB Temperature Absent Start time 2017-11-05 22:14:01 PST Uptime 2 days, 8 hours, 5 minutes, 55 seconds
mostrar FPC del chasis <ranura FPC> (enrutador MX204)
user@host> show chassis fpc 0 Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online Absent 8 0 8 8 8 3136 8 8
mostrar fpc del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 31 20 0 3584 7 13 1 Online 28 19 0 2048 17 13 2 Online 27 10 0 2048 18 14 3 Online 26 10 0 2048 13 13 4 Online 29 19 0 3584 7 13 5 Online 28 68 0 2048 20 13 6 Empty 7 Empty 8 Empty 9 Online 36 19 0 3584 10 13 10 Online 37 26 0 3584 10 13 11 Empty 12 Empty 13 Empty 14 Empty 15 Empty 16 Empty 17 Online 28 43 0 3584 10 13 18 Online 29 19 0 3584 7 13 19 Online 31 19 0 3584 7 13
mostrar detalles de FPC del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
user@host> show chassis fpc detail Slot 0 information: State Online Temperature 31 Total CPU DRAM 3584 MB Total XR2 291 MB Total DDR DRAM 24960 MB Start time: 2014-04-22 23:33:19 PDT Uptime: 6 minutes, 24 seconds Max Power Consumption 607 Watts Slot 1 information: State Online Temperature 28 Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 6656 MB Start time: 2014-04-22 23:33:24 PDT Uptime: 6 minutes, 19 seconds Max Power Consumption 520 Watts Slot 2 information: State Online Temperature 27 Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 11264 MB Start time: 2014-04-22 23:33:34 PDT Uptime: 6 minutes, 9 seconds Max Power Consumption 608 Watts Slot 3 information: State Online Temperature 26 Total CPU DRAM 2048 MB Total RLDRAM 734 MB Total DDR DRAM 3108 MB Start time: 2014-04-22 23:33:39 PDT Uptime: 6 minutes, 4 seconds Max Power Consumption 368 Watts Slot 4 information: State Online Temperature 29 Total CPU DRAM 3584 MB Total XR2 291 MB Total DDR DRAM 24960 MB Start time: 2014-04-22 23:33:51 PDT Uptime: 5 minutes, 52 seconds Max Power Consumption 607 Watts Slot 5 information: State Online Temperature 28 Total CPU DRAM 2048 MB Total RLDRAM 1324 MB Total DDR DRAM 5120 MB Start time: 2014-04-22 23:33:57 PDT Uptime: 5 minutes, 46 seconds Max Power Consumption 440 Watts Slot 9 information: State Online Temperature 25 Total CPU DRAM 3584 MB Total XR2 518 MB Total DDR DRAM 49920 MB Start time: 2014-04-22 23:31:20 PDT Uptime: 8 minutes, 23 seconds Max Power Consumption 1130 Watts Slot 10 information: State Online Temperature 32 Total CPU DRAM 3584 MB Total XR2 518 MB Total DDR DRAM 49920 MB Start time: 2014-04-22 23:31:25 PDT Uptime: 8 minutes, 18 seconds Max Power Consumption 1130 Watts Slot 17 information: State Online Temperature 25 Total CPU DRAM 3584 MB Total XR2 518 MB Total DDR DRAM 49920 MB Start time: 2014-04-22 23:31:29 PDT Uptime: 8 minutes, 14 seconds Max Power Consumption 1130 Watts Slot 18 information: State Online Temperature 29 Total CPU DRAM 3584 MB Total XR2 291 MB Total DDR DRAM 24960 MB Start time: 2014-04-22 23:34:11 PDT Uptime: 5 minutes, 32 seconds Max Power Consumption 607 Watts Slot 19 information: State Online Temperature 32 Total CPU DRAM 3584 MB Total XR2 291 MB Total DDR DRAM 24960 MB Start time: 2014-04-22 23:34:20 PDT Uptime: 5 minutes, 23 seconds Max Power Consumption 607 Watts
mostrar el estado de la imagen FPC del chasis (enrutador MX2020 con MPC5EQ y MPC6E)
user@host> show chassis fpc pic-status Slot 0 Online MPC5E 3D Q 24XGE+6XLGE PIC 0 Online 12X10GE SFPP OTN PIC 1 Online 12X10GE SFPP OTN PIC 2 Offline 3X40GE QSFPP PIC 3 Offline 3X40GE QSFPP Slot 1 Online MPCE Type 3 3D PIC 0 Online 10X10GE SFPP PIC 2 Online 1X100GE CXP Slot 2 Online MPC4E 3D 2CGE+8XGE PIC 0 Online 4x10GE SFPP PIC 1 Online 1X100GE CFP PIC 2 Online 4x10GE SFPP PIC 3 Online 1X100GE CFP Slot 3 Online MPCE Type 2 3D P PIC 0 Online 2x 10GE XFP PIC 1 Online 2x 10GE XFP Slot 4 Online MPC5E 3D Q 2CGE+4XGE PIC 0 Online 2X10GE SFPP OTN PIC 1 Online 1X100GE CFP2 OTN PIC 2 Online 2X10GE SFPP OTN PIC 3 Online 1X100GE CFP2 OTN Slot 5 Online MPC 3D 16x 10GE PIC 0 Online 4x 10GE(LAN) SFP+ PIC 1 Online 4x 10GE(LAN) SFP+ PIC 2 Online 4x 10GE(LAN) SFP+ PIC 3 Online 4x 10GE(LAN) SFP+ Slot 9 Online MPC6E 3D PIC 0 Online 2X100GE CFP2 OTN PIC 1 Online 2X100GE CFP2 OTN Slot 10 Online MPC6E 3D PIC 0 Online 24X10GE SFPP OTN PIC 1 Online 4X100GE CXP Slot 17 Online MPC6E 3D PIC 0 Online 24X10GE SFPP PIC 1 Online 4X100GE CXP Slot 18 Online MPC5E 3D Q 24XGE+6XLGE PIC 0 Offline 12X10GE SFPP OTN PIC 1 Offline 12X10GE SFPP OTN PIC 2 Online 3X40GE QSFPP PIC 3 Online 3X40GE QSFPP Slot 19 Online MPC5E 3D Q 24XGE+6XLGE PIC 0 Online 12X10GE SFPP OTN PIC 1 Offline 12X10GE SFPP OTN PIC 2 Offline 3X40GE QSFPP PIC 3 Online 3X40GE QSFPP
mostrar detalles de FPC del chasis (enrutadores de la serie MX)
user@host> show chassis fpc detail 2 Slot 0 information: State Online Temperature 36 degrees C / 96 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2009-08-11 21:20:30 PDT Uptime: 2 hours, 8 minutes, 50 seconds Max Power Consumption 335 Watts
mostrar detalles de fpc del chasis (conmutadores de la serie EX)
user@host> show chassis fpc detail 2 Slot 1 information: State Online Temperature 41 Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 11264 MB Start time: 2013-04-02 00:04:52 PDT Uptime: 7 days, 9 hours, 47 minutes, 46 seconds Max Power Consumption 610 Watts Slot 2 information: State Online Temperature 41 Total CPU DRAM 2048 MB Total RLDRAM 1036 MB Total DDR DRAM 11264 MB Start time: 2013-04-02 00:04:56 PDT Uptime: 7 days, 9 hours, 47 minutes, 42 seconds Max Power Consumption 610 Watts
mostrar detalles de FPC del chasis (conmutadores EX9251)
user@switch> show chassis fpc detail 2 Slot 0 information: State Online Total CPU DRAM 3136 MB Total RLDRAM 257 MB Total DDR DRAM 4096 MB Temperature Absent Start time 2018-03-12 14:59:49 PDT Uptime 1 day, 1 hour, 10 minutes, 48 seconds
mostrar detalles de FPC del chasis (conmutadores EX9253)
user@switch> show chassis fpc detail 1 Slot 1 information: State Online Total CPU DRAM 3136 MB Total RLDRAM 771 MB Total DDR DRAM 18432 MB Temperature 59 degrees C / 138 degrees F Start time 2018-03-04 14:20:42 PST Uptime 3 days, 10 hours, 40 minutes, 57 seconds Max MPC base power consumption 910 Watts Max MIC1 power consumption 95 Watts Max MPC total power consumption 1005 Watts
mostrar fpc del chasis (hardware no compatible)
user@host> show chassis fpc show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online -------------------- CPU less FPC -------------------- 1 Present ------ Hardware Not In Right Slot ------ 2 Online 0 0 0 0 0 3 Present ------ Hardware Not Supported ------ 4 Empty 5 Empty 6 Online 0 0 0 0 0
Mostrar detalles de FPC del chasis (hardware no compatible)
user@host> show chassis fpc detail Slot 0 information: State Online Total CPU DRAM ---- CPU less FPC ---- Start time 2006-07-07 03:21:00 UTC Uptime 27 minutes, 51 seconds Slot 1 information: State Present Reason --- Hardware Not In Right Slot --- Slot 2 information: State Online Total CPU DRAM 32 MB Start time 2006-07-07 03:20:59 UTC Uptime 27 minutes, 52 seconds Slot 3 information: State Present Reason --- Hardware Not Supported --- Total CPU DRAM 0 MB Slot 6 information: State Online Total CPU DRAM 32 MB Start time 2006-07-07 03:21:01 UTC Uptime 27 minutes, 50 seconds
mostrar el estado de la PIC de FPC del chasis
user@host> show chassis fpc pic-status Slot 0 Online PIC 1 1x OC-12 ATM, MM PIC 2 1x OC-12 ATM, MM PIC 3 1x OC-12 ATM, MM Slot 1 Online PIC 0 1x OC-48 SONET, SMIR Slot 2 Online PIC 0 1x OC-192 SONET, SMSR
mostrar el estado de la imagen FPC del chasis (enrutadores de la serie M)
user@host> show chassis fpc pic-status Slot 1 Online FPC Type 1 PIC 0 Present 2x OC-3 ATM, MM- Hardware Error PIC 1 Online 4x OC-3 SONET, SMIR Slot 2 Online E-FPC Type 2 PIC 0 Online 4x G/E, 1000 BASE-SX PIC 1 Online 2x G/E SFP, 1000 BASE PIC 3 Online 1x Tunnel Slot 3 Online E-FPC Type 1 PIC 0 Online 1x G/E IQ, 1000 BASE PIC 2 Online 1x G/E SFP, 1000 BASE Slot 4 Online E-FPC Type 2 PIC 0 Online 4x G/E SFP, 1000 BASE PIC 1 Online 4x G/E SFP, 1000 BASE PIC 2 Online 4x G/E SFP, 1000 BASE PIC 3 Online 4x G/E SFP, 1000 BASE Slot 5 Online FPC Type 2 ...
mostrar el estado de la imagen FPC del chasis (enrutadores MX240, MX480 y MX960 con tarjeta de línea modular de servicios de aplicación)
En el siguiente resultado Slot 1 and Slot 5 se encuentran las tarjetas portadoras modulares de servicios de aplicaciones (AS MCC), PIC 0 la tarjeta de almacenamiento modular de servicios de aplicaciones (AS MSC) y PIC 2 la tarjeta de procesamiento modular de servicios de aplicaciones (AS MXC).
user@host>show chassis fpc pic-status Slot 2 Online MPC Type 1 3D Q Slot 1 Online AS-MCC PIC 0 Online AS-MSC PIC 2 Online AS-MXC Slot 4 Offline MPC 3D 16x 10GE Slot 5 Offline AS-MCC
mostrar FPC del chasis <ranura FPC> (conmutador de la serie EX)
user@host> show chassis fpc 2 Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 2 Online 40 12 0 2048 19 14
mostrar fpc del chasis (enrutador MX10008 con MX10K-LC9600 y SFB)
MX10K-LC9600 solo admite SFB2. El siguiente resultado indica que MX10K-LC9600 es compatible con SFB.
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Offline Offlined due to Unsupported fabric
mostrar fpc del chasis (series QFX y OCX)
user@switch> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 26 2 0 2820 0 49
mostrar detalles de FPC del chasis (conmutadores QFX3500)
user@switch> show chassis fpc detail Slot 0 information: State Online Temperature 28 degrees C / 82 degrees F Total CPU DRAM 2820 MB Total SRAM 0 MB Total SDRAM 0 MB Start time 2010-09-20 01:34:13 PDT Uptime 3 days, 3 hours, 31 minutes, 48 seconds
mostrar el estado de la imagen FPC del chasis (conmutadores QFX3500)
user@switch> show chassis fpc pic-status Slot 0 Online QFX 48x10G 4x40G Switch PIC 0 Online 48x 10G-SFP+ PIC 1 Online 15x 10G-SFP+
mostrar dispositivo de interconexión FPC del chasis (sistema QFabric)
user@switch> show chassis fpc interconnect-device interconnect1 FPC status: Temp Slot State (C) 0 Online 0 1 Online 0 2 Online 0 3 Online 0 4 Online 0 5 Online 0 6 Online 0 7 Online 0 8 Online 0 9 Online 0 10 Online 0 11 Online 0 12 Online 0 13 Online 0 14 Online 0 15 Online 0
mostrar dispositivo de interconexión FPC del chasis (sistema QFabric)
user@switch> show chassis fpc interconnect-device interconnect1 3 FPC status: Temp Slot State (C) 3 Online 0
mostrar detalles del dispositivo de interconexión FPC del chasis (sistema QFabric)
user@switch> show chassis fpc interconnect-device interconnect1 3 detail Slot 3 information: State Online Temperature 0 degrees C / 32 degrees F Start time 2011-08-18 10:45:04 PDT Uptime 1 minute, 49 seconds
mostrar el dispositivo de interconexión de estado PIC FPC del chasis (sistema QFabric)
user@switch> show chassis fpc pic-status interconnect-device interconnect1 Slot 0 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 1 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 2 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 3 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 4 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 5 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 6 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 7 Online QFX 16-port QSFP+ Front Card PIC 0 Online 16x 40G-QSFP+ PIC 1 Online 16x 40G-GE Slot 8 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 9 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 10 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 11 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 12 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 13 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 14 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE Slot 15 Online QFX Fabric Rear Card PIC 0 Online 16x 40G-GE
mostrar nodo de estado FPC del chasis (sistema QFabric)
user@switch> show chassis fpc pic-status node-device node1 Slot node1 Online QFX 48x10G 4x40G Switch PIC 0 Online 48x 10G-SFP+ PIC 1 Online 4x 40G-QSFP+
Mostrar FPC del chasis (PTX10008)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 38 26 2 26 26 26 1953 20 32 1 Empty 2 Empty 3 Empty 4 Empty 5 Online 67 26 2 26 26 26 1953 25 32 6 Online 52 26 2 26 26 26 1953 25 32 7 Empty
mostrar todas las instancias de PFE de FPC del chasis (enrutador PTX10008 y PTX10001-36MR)
Para ver la información del estado de PFE para todos los FPC y PFE del dispositivo:
user@host> show chassis fpc pfe-instance all FPC 0 PFE-Instance PFE-State 0 Configured power off 1 Configured power off 2 Configured power off 3 Configured power off 4 Configured power off FPC 2 PFE-Instance PFE-State 0 Configured power off 1 Configured power off 2 Configured power off 3 Configured power off 4 TRANSITION_OFFLINE FPC 3 PFE-Instance PFE-State 0 ONLINE 1 ONLINE 2 Offlined by CmError 3 ONLINE 4 Offlined by CLI
Mostrar detalles de FPC del chasis (PTX10008)
user@host> show chassis fpc detail Slot 6 information: State Online Total CPU DRAM 8192 MB Temperature 42 degrees C / 107 degrees F Start time 2018-09-17 02:42:16 PDT Uptime 53 minutes, 40 seconds Max power consumption 675 Watts Slot 7 information: State Online Total CPU DRAM 8192 MB Temperature 51 degrees C / 123 degrees F Start time 2018-09-17 02:42:26 PDT Uptime 53 minutes, 30 seconds Max power consumption 1150 Watts
mostrar fpc del chasis (enrutador PTX10016)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Empty 1 Online 36 27 2 27 27 27 1953 22 32 2 Empty 3 Online 36 27 2 27 27 27 1953 22 32 4 Empty 5 Empty 6 Online 35 27 2 27 27 27 1953 22 32 7 Empty 8 Online 34 27 2 27 27 27 1953 22 32 9 Online 46 24 2 24 24 24 1953 26 32 10 Empty 11 Empty 12 Empty 13 Empty 14 Empty 15 Empty
mostrar detalles de FPC del chasis (enrutador PTX10016)
user@host> show chassis fpc detail Slot 0 information: State Online Total CPU DRAM 8192 MB Temperature 44 degrees C / 111 degrees F Start time 2018-09-10 07:01:09 PDT Uptime 6 days, 23 hours, 17 minutes, 9 seconds Max power consumption 1150 Watts Slot 4 information: State Online Total CPU DRAM 8192 MB Temperature 40 degrees C / 104 degrees F Start time 2018-09-10 07:01:17 PDT Uptime 6 days, 23 hours, 17 minutes, 1 second Max power consumption 1150 Watts Slot 6 information: State Online Total CPU DRAM 8192 MB Temperature 42 degrees C / 107 degrees F Start time 2018-09-10 07:01:27 PDT Uptime 6 days, 23 hours, 16 minutes, 51 seconds Max power consumption 1150 Watts Slot 7 information: State Online Total CPU DRAM 8192 MB Temperature 41 degrees C / 105 degrees F Start time 2018-09-10 07:01:32 PDT Uptime 6 days, 23 hours, 16 minutes, 46 seconds Max power consumption 1150 Watts Slot 9 information: State Online Total CPU DRAM 16384 MB Temperature 42 degrees C / 107 degrees F Start time 2018-09-10 07:01:45 PDT Uptime 6 days, 23 hours, 16 minutes, 33 seconds Max power consumption 1150 Watts Slot 10 information: State Online Total CPU DRAM 8192 MB Temperature 41 degrees C / 105 degrees F Start time 2018-09-10 07:01:46 PDT Uptime 6 days, 23 hours, 16 minutes, 32 seconds Max power consumption 1150 Watts Slot 11 information: State Online Total CPU DRAM 16384 MB Temperature 40 degrees C / 104 degrees F Start time 2018-09-10 07:01:55 PDT Uptime 6 days, 23 hours, 16 minutes, 23 seconds Max power consumption 1150 Watts Slot 14 information: State Online Total CPU DRAM 8192 MB Temperature 42 degrees C / 107 degrees F Start time 2018-09-10 07:01:54 PDT Uptime 6 days, 23 hours, 16 minutes, 24 seconds Max power consumption 1150 Watts Slot 15 information: State Online Total CPU DRAM 16384 MB Temperature 41 degrees C / 105 degrees F Start time 2018-09-10 07:02:03 PDT Uptime 6 days, 23 hours, 16 minutes, 15 seconds Max power consumption 1150 Watts
mostrar FPC 1 del chasis (enrutadores MX con hoja Servicios multimedia [MSB])
user@switch> show chassis fpc 1 Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 1 Online 34 5 0 3072 5 13
mostrar detalles del FPC 1 del chasis (enrutadores MX con blade Servicios multimedia [MSB])
user@switch> show chassis fpc 1 detail Slot 1 information: State Online Temperature 34 Total CPU DRAM 3072 MB Total RLDRAM 259 MB Total DDR DRAM 4864 MB Start time: 2012-06-19 10:51:43 PDT Uptime: 16 minutes, 48 seconds Max Power Consumption 550 Watts
mostrar detalle de fpc del chasis (MX304)
user@router> show chassis fpc detail
Slot 0 information:
State Online
Total CPU DRAM 32768 MB
Total HBM 65536 MB
FIPS Capable True
Temperature 52 degrees C / 125 degrees F
Start time 2022-06-06 16:47:31 IST
Uptime 19 hours, 2 minutes, 33 seconds
Max MPC base power consumption 1105 Watts
Max MIC0 power consumption 95 Watts
Max MIC1 power consumption 95 Watts
Max MPC total power consumption 1295 Watts
PFE Information:
PFE Power ON/OFF Bandwidth SLC
0 ON 800G
1 ON 800G
2 ON 800G
3 ON 800G
4 OFF _
5 OFF _
mostrar el estado del micrófono FPC del chasis (MX304 con LMIC)
user@host> show chassis fpc mic-status 0 Slot 0 Online FPC-BUILTIN MIC 0 Online MRATE LMIC 16x100G/4x400G PIC 0 Online MRATE LMIC 16x100G/4x400G MIC 1 Online MRATE LMIC 16x100G/4x400G PIC 1 Online MRATE LMIC 16x100G/4x400G MIC 2 Online MRATE LMIC 16x100G/4x400G PIC 2 Online MRATE LMIC 16x100G/4x400G
Resultado de muestra (Junos OS evolucionado)
- mostrar FPC del chasis (Junos OS evolucionado)
- mostrar chasis fpc 0 pfe todos (PTX10002-36QDD)
- mostrar instancia de PFE de FPC del chasis (PTX10008, Junos OS evolucionado)
- mostrar el estado de la imagen FPC del chasis (PTX10016, Junos OS evolucionado)
- mostrar FPC de chasis PFE (PTX10004, PTX10008 PTX100016 con tarjetas de línea PTX10K-LC1201-36CD y PTX10K-LC1202-36MR, y PTX10001-36MR)
- mostrar fpc del chasis (serie ACX7000)
mostrar FPC del chasis (Junos OS evolucionado)
user@router> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 1 Offline ---Configured power off--- 4 Online 54 2 0 2 2 2 16384 37 1 5 Offline ---Configured power off---
El show chassis fpc
comando no muestra los detalles de uso de CPU y memoria en enrutadores de configuración fija, como PTX10001-36MR, PTX10003-80C, PTX10003-160C, etc., ya que los FPC de estos enrutadores no tienen CPU ni memoria dedicadas.
En los dispositivos PTX10003-80C y PTX10003-160C, si ha configurado una unidad reemplazable en campo (FRU) para que se apague y reinicie el dispositivo, el show chassis fpc
resultado mostrará el estado de la FRU como Presente y el motivo como Configured power off
. Vea el siguiente resultado:
user@router> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Present ---Configured power off--- 1 Online
El show chassis fpc
resultado muestra el motivo sin conexión de FPC como Offlined by cli command
cuando el FPC se desconecta debido a un error mayor o grave de FPC. Este comportamiento sólo es aplicable si ha configurado la acción sin conexión para la gravedad de error grave o grave, mediante el comando set chassis error major action offline
. Vea el siguiente resultado:
user@router> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Offline ---Offlined by cli command--- 1 Online
mostrar chasis fpc 0 pfe todos (PTX10002-36QDD)
user@host> show chassis fpc 0 pfe all FPC 0 PFE PFE-Instance PFE-State 0 0 Configured power off 1 0 Configured power off 2 1 ONLINE 3 1 ONLINE
mostrar instancia de PFE de FPC del chasis (PTX10008, Junos OS evolucionado)
user@host> run show chassis fpc pfe-instance all FPC 0 PFE-Instance PFE-State 0 Configured power off <<< PFE Offline via Config 1 ONLINE 2 ONLINE 3 ONLINE 4 ONLINE
mostrar el estado de la imagen FPC del chasis (PTX10016, Junos OS evolucionado)
user@host> show chassis fpc pic-status Slot 0 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 1 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 2 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 3 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 4 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 5 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 6 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 7 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 8 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 9 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 10 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 11 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 12 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 13 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 14 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC Slot 15 Online JNP10K-LC1201 PIC 0 Online JNP10K-36QDD-LC-PIC
mostrar FPC de chasis PFE (PTX10004, PTX10008 PTX100016 con tarjetas de línea PTX10K-LC1201-36CD y PTX10K-LC1202-36MR, y PTX10001-36MR)
user@router> show chassis fpc 0 pfe-instance all FPC 0 PFE-Instance PFE-State 0 ONLINE 1 ONLINE 2 ONLINE
user@router> show chassis fpc 0 pfe-instance all detail FPC 0 PFE-Instance PFE-State PPFE-ID Temp-Perf-Throttle Temp-Volt-Reduction 0 ONLINE 0, 1 Enabled Enabled|Nominal 1 ONLINE 2, 3 Enabled Enabled|Nominal 2 ONLINE 4, 5 Enabled Enabled|Nominal 3 ONLINE 6, 7 Enabled Enabled|Optimized 4 ONLINE 8 Enabled Enabled|Nominal
user@router> show chassis fpc 0 pfe-instance 0 detail FPC 0 PFE-Instance PFE-State PPFE-ID Temp-Perf-Throttle Temp-Volt-Reduction 0 ONLINE 0, 1 Enabled Enabled
mostrar fpc del chasis (serie ACX7000)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online
user@host> show chassis fpc detail Slot 0 information: State Online Start time 2024-08-06 23:58:02 PDT Uptime 7 hours, 38 seconds Max power consumption 825 Watts
user@host> show chassis fpc pic-status Slot 0 Online ACX7100-48L PIC 0 Online MRATE- 48xSFP56 + 6xQSFP56-DD
Salida de muestra (división de nodos)
- mostrar FPC (división de nodos) del chasis
- mostrar el estado de la imagen FPC del chasis (división de nodos)
mostrar FPC (división de nodos) del chasis
user@router>show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer GNF 0 Online 45 12 0 12 12 12 3584 6 25 3 1 Online 57 22 0 20 20 20 3136 16 22 2 2 Online 50 19 0 17 17 16 3584 6 25 3 3 Online 28 10 0 11 11 11 2048 10 20 6 4 Online 42 20 0 20 19 19 3584 8 25 6 5 Online 58 22 0 21 20 20 3136 16 22 4 6 Online 49 17 0 15 16 16 3136 13 20 1 7 Online 44 11 0 10 10 10 3584 6 25 5 8 Online 40 19 0 18 18 18 3584 8 25 5 9 Online 44 19 0 20 20 20 3584 8 25 5
mostrar el estado de la imagen FPC del chasis (división de nodos)
user@router> show chassis fpc pic-status Slot 0 Online MPC5E 3D 24XGE+6XLGE GNF 3 PIC 0 Online 12X10GE SFPP OTN PIC 1 Offline 12X10GE SFPP OTN PIC 2 Offline 3X40GE QSFPP PIC 3 Online 3X40GE QSFPP Slot 1 Online MPC9E 3D GNF 2 PIC 1 Online MRATE-12xQSFPP-XGE-XLGE-CGE Slot 2 Online MPC5E 3D Q 2CGE+4XGE GNF 3 PIC 0 Online 2X10GE SFPP OTN PIC 1 Online 1X100GE CFP2 OTN PIC 2 Online 2X10GE SFPP OTN PIC 3 Online 1X100GE CFP2 OTN Slot 3 Online MPCE Type 2 3D EQ GNF 6 Slot 4 Online MPC6E 3D GNF 6 PIC 0 Online 24X10GE SFPP PIC 1 Online 2X100GE CFP2 OTN Slot 5 Online MPC9E 3D GNF 4 PIC 0 Online MRATE-12xQSFPP-XGE-XLGE-CGE Slot 6 Online MPC7E 3D MRATE-12xQSFPP-XGE-XLGE-CGE GNF 1 PIC 0 Online MRATE-6xQSFPP-XGE-XLGE-CGE PIC 1 Online MRATE-6xQSFPP-XGE-XLGE-CGE Slot 7 Online MPC5E 3D 2CGE+4XGE GNF 5 PIC 0 Online 2X10GE SFPP OTN PIC 1 Online 1X100GE CFP2 OTN PIC 2 Online 2X10GE SFPP OTN PIC 3 Online 1X100GE CFP2 OTN Slot 8 Online MPC6E 3D GNF 5 PIC 0 Online 24X10GE SFPP OTN Slot 9 Online MPC6E 3D GNF 5 PIC 0 Online 24X10GE SFPP PIC 1 Online 4X100GE CXP
mostrar fpc del chasis (dispositivos MX10004 y MX10008)
En dispositivos MX10004 y MX10008, las tarjetas de línea JNP10K-LC4800 se ENCIENDEN únicamente cuando están presentes los siguientes componentes compatibles:
- Bandejas de ventilador : JNP10004-FAN2, JNP10008-FAN2
- PSM o PEM: JNP10K-PWR-AC2, JNP10K-PWR-AC3, JNP10K-PWR-DC2
- Placa de estructura de conmutación mejorada (SFB2)
El show chassis fpc
resultado del comando muestra el siguiente mensaje de error cuando no hay bandejas de ventilador compatibles:
user@host> show chassis fpc 3 Temp CPU Utilization (%) Memory Utilization (%) Slot State I Total Interrupt DRAM (MB) Heap Buffer 3 Offline ---FPC incompatible with FAN-TRAYs ---
show chassis fpc
resultado del comando muestra el siguiente mensaje de error cuando no hay PSM o PEM compatibles:
user@router> show chassis sfb slot 0 Slot State Uptime 0 Offline ---SFB incompatible with PEMs ---
- Mostrar FPC del chasis (dispositivos SRX5600 y SRX5800)
- Mostrar dispositivos FPC (SRX5400, SRX5600 y SRX5800 del chasis con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3)
Mostrar FPC del chasis (dispositivos SRX5600 y SRX5800)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 1 Empty 2 Empty 3 Online 37 3 0 1024 7 42 4 Empty 5 Empty 6 Online 30 8 0 1024 23 30 7 Empty 8 Empty 9 Empty 10 Empty 11 Empty
Mostrar dispositivos FPC (SRX5400, SRX5600 y SRX5800 del chasis con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 36 20 0 20 19 19 1024 4 26 1 Online 35 8 0 8 8 8 2048 12 14 2 Online 40 21 0 20 20 20 3584 5 13
Salida de muestra
Mostrar detalle de FPC del chasis 2
user@host> show chassis fpc detail 2 Slot 2 information: State Online Temperature 37 Total CPU DRAM 1024 MB Total RLDRAM 0 MB Total DDR DRAM 0 MB Start time: 2012-07-18 07:18:50 PDT Uptime: 4 days, 21 hours, 51 minutes, 59 seconds Max Power Consumption 0 Watts
Salida de muestra
- Mostrar el estado de la PIC FPC del chasis (dispositivos SRX5600 y SRX5800)
- mostrar el estado de la PIC FPC del chasis (dispositivos SRX5600 y SRX5800 con SPC2)
- mostrar el estado de PIC FPC del chasis (SRX5600 y dispositivos SRX5800 con SRX5K-MPC)
- muestra el estado de PIC FPC del chasis (SRX5600 y SRX5800 dispositivos cuando Express Path [anteriormente conocido como descarga de servicios] está configurado)
- mostrar el estado de la PIC FPC del chasis (con MIC de 20 Gigabit Ethernet con SFP)
- mostrar el estado de PIC FPC del chasis (SRX5400, SRX5600 y dispositivos SRX5800 con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3 y cuando Express Path [anteriormente conocido como descarga de servicios] está configurado)
Mostrar el estado de la PIC FPC del chasis (dispositivos SRX5600 y SRX5800)
user@host> show chassis fpc pic-status Slot 3 Online SRX5k SPC PIC 0 Online SPU Cp PIC 1 Online SPU Flow Slot 6 Online SRX5k DPC 4x 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ
mostrar el estado de la PIC FPC del chasis (dispositivos SRX5600 y SRX5800 con SPC2)
user@host> show chassis fpc pic-status Slot 0 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 2 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 3 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 5 Online SRX5k SPC PIC 0 Online SPU Flow PIC 1 Online SPU Flow
mostrar el estado de PIC FPC del chasis (SRX5600 y dispositivos SRX5800 con SRX5K-MPC)
user@host> show chassis fpc pic-status Slot 0 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 1 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 6 Offline SRX5k SPC II Slot 9 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 10 Online SRX5k IOC II PIC 0 Online 10x 10GE SFP+ PIC 2 Online 1x 100GE CFP Slot 11 Online SRX5k IOC II PIC 0 Online 1x 100GE CFP PIC 2 Online 2x 40GE QSFP+
muestra el estado de PIC FPC del chasis (SRX5600 y SRX5800 dispositivos cuando Express Path [anteriormente conocido como descarga de servicios] está configurado)
user@host> show chassis fpc pic-status Slot 0 Offline SRX5k DPC 40x 1GE Slot 1 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Offline SRX5k SPC Slot 4 Online SRX5k IOC3 24XGE+6XLG PIC 2 Online 3x 40GE QSFP+- np-cache/services-offload PIC 3 Online 3x 40GE QSFP+- np-cache/services-offload Slot 5 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 1 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 2 Online 10x 10GE SFP+- np-cache/services-offload
mostrar el estado de la PIC FPC del chasis (con MIC de 20 Gigabit Ethernet con SFP)
user@host> show chassis fpc pic-status node0: -------------------------------------------------------------------------- Slot 0 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 1 Offline SRX5k SPC II Slot 2 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 9 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP PIC 1 Online 10x 1GE(LAN) SFP PIC 2 Online 10x 1GE(LAN) SFP PIC 3 Online 10x 1GE(LAN) SFP Slot 10 Online SRX5k IOC II PIC 0 Online 10x 10GE SFP+ PIC 2 Online 1x 100GE CFP Slot 11 Offline SRX5k IOC II
mostrar el estado de PIC FPC del chasis (SRX5400, SRX5600 y dispositivos SRX5800 con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3 y cuando Express Path [anteriormente conocido como descarga de servicios] está configurado)
user@host> show chassis fpc pic-status Slot 0 Offline SRX5k DPC 40x 1GE Slot 1 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Offline SRX5k SPC Slot 4 Online SRX5k IOC3 24XGE+6XLG PIC 2 Online 3x 40GE QSFP+- np-cache/services-offload PIC 3 Online 3x 40GE QSFP+- np-cache/services-offload Slot 5 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 1 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 2 Online 10x 10GE SFP+- np-cache/services-offload
Salida de muestra
- mostrar el estado de PIC FPC del chasis para alta disponibilidad (dispositivos SRX5600 y SRX5800)
- muestra el estado de PIC FPC del chasis para dispositivos de alta disponibilidad (SRX5400, SRX5600 y SRX5800 con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3)
mostrar el estado de PIC FPC del chasis para alta disponibilidad (dispositivos SRX5600 y SRX5800)
user@host> show chassis fpc pic-status node0: ------------------------------------------------------------ Slot 4 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 5 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow node1: -------------------------------------------------------------- Slot 4 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 5 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow
muestra el estado de PIC FPC del chasis para dispositivos de alta disponibilidad (SRX5400, SRX5600 y SRX5800 con SRX5K-MPC3-100G10G (IOC3) o SRX5K-MPC3-40G10G (IOC3)
user@host> show chassis fpc pic-status user@host> show chassis fpc pic-status node0: -------------------------------------------------------------------------- Slot 2 Online SRX5k IOC3 24XGE+6XLG PIC 0 Online 12x 10GE SFP+ PIC 1 Online 12x 10GE SFP+ PIC 2 Offline 3x 40GE QSFP+ PIC 3 Offline 3x 40GE QSFP+ Slot 4 Online SRX5k IOC II PIC 2 Online 10x 10GE SFP+ Slot 5 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Offline PIC 3 Offline node1: -------------------------------------------------------------------------- Slot 2 Online SRX5k IOC3 24XGE+6XLG PIC 0 Online 12x 10GE SFP+ PIC 1 Online 12x 10GE SFP+ PIC 2 Offline 3x 40GE QSFP+ PIC 3 Offline 3x 40GE QSFP+ Slot 4 Online SRX5k IOC II PIC 2 Online 10x 10GE SFP+ Slot 5 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Offline PIC 3 Offline
Uso
- Para mostrar toda la información de PFE junto con el estado del acelerador de rendimiento de temperatura para la ranura FPC 1 (FPC 0), utilice el comando
show chassis fpc 0 pfe-instance all detail
. - Para mostrar solo información de PFE 0 junto con el estado del acelerador de rendimiento de temperatura para la ranura FPC 1 (FPC 0), utilice el comando
show chassis fpc 0 pfe-instance 0 detail
.
Información de la versión
Comando introducido antes de la versión 7.4 de Junos OS.
Se agregó la opción de instancia de pfe en Junos OS Evolved versión 21.4R1.