show chassis alarms
Sintaxis
show chassis alarms
Sintaxis (enrutadores de la serie MX)
show chassis alarms <all-members> <local> <member member-id>
Sintaxis (SRX1500, SRX4100 y SRX4200)
show chassis alarms 1 alarms currently active Alarm time Class Description 2020-02-28 10:07:16 CST Major FPC0: PEM 0 Not Present
Sintaxis (SRX4600)
show chassis alarms node0: -------------------------------------------------------------------------- 2 alarms currently active Alarm time Class Description 2020-10-08 19:42:06 UTC Major FPC 0 BITS CPLD Version Mismatch 2020-10-08 19:42:06 UTC Minor PEM 1 Not Present
Sintaxis (SRX5400)
show chassis alarms 1 alarms currently active Alarm time Class Description 2021-04-16 17:21:02 PDT Major Too Few AC PEMs
Sintaxis (enrutadores de matriz TX)
show chassis alarms <lcc number | scc>
Sintaxis (enrutadores TX Matrix Plus)
show chassis alarms <lcc number | sfc number>
Sintaxis (plataformas de enrutamiento universal MX104, MX2010, MX2020 y MX2008)
show chassis alarms <satellite [slot-id slot-id]>
Sintaxis (serie QFX)
show chassis alarms <interconnect-device name> <node-device name>
Descripción
Muestra información sobre las condiciones que se han configurado para activar alarmas. En Junos, las alarmas del chasis son diferentes de las alarmas del sistema (se ven mediante el show system alarms
comando). Las alarmas del sistema indican que falta una configuración de rescate o una licencia de software, si son válidas. Para obtener más información, consulte Descripción general de alarmas.
Opciones
none | Muestra información sobre las condiciones que se han configurado para activar alarmas. |
all-members | (Solo enrutadores de la serie MX) (Opcional) Muestra información sobre las condiciones de alarma para todos los enrutadores miembros de la configuración del chasis virtual. |
interconnect-device name | (Solo sistemas QFabric) (Opcional) Muestra información sobre las condiciones de alarma del dispositivo de interconexión. |
lcc number | (Solo enrutador TX Matrix y enrutador TX Matrix Plus) (Opcional) Número de chasis de la tarjeta de línea. Reemplace number por los siguientes valores según la configuración de LCC:
|
local | (Solo enrutadores de la serie MX) (Opcional) Muestra información sobre las condiciones de alarma para el miembro local de Virtual Chassis. |
member member-id | (Solo enrutadores de la serie MX) (Opcional) Muestra información sobre las condiciones de alarma para el miembro especificado de la configuración del Virtual Chassis. Reemplace member-id la variable con un valor de 0 o 1. |
node-device name | (Solo sistemas QFabric) (Opcional) Muestra información sobre las condiciones de alarma para el dispositivo Node. |
satellite [slot-id slot-id] | (Solo Junos Fusion)(Opcional) Muestra información sobre las condiciones de alarma para el dispositivo satelital especificado en Junos Fusion o para todos los dispositivos satelitales en Junos Fusion si no se especifica ningún dispositivo satelital. |
scc | (Solo enrutador TX Matrix) (Opcional) Mostrar información sobre el enrutador TX Matrix (chasis de tarjeta de conmutación). |
sfc number | (Solo enrutador TX Matrix Plus) (Opcional) Mostrar información sobre el enrutador TX Matrix Plus respectivo, que es el chasis de la estructura del conmutador. Reemplace number variable por |
Información adicional
Las alarmas del chasis están preestablecidas. No puede modificarlos.
No puede borrar las alarmas de los componentes del chasis. En su lugar, debe remediar la causa de la alarma. Cuando se enciende un LED de alarma de chasis, indica que está ejecutando el enrutador o conmutador de una manera que no recomendamos.
En los enrutadores, puede silenciar manualmente los dispositivos externos conectados a los contactos del relé de alarma presionando el botón de corte de alarma, ubicado en la interfaz de la nave. Al silenciar el dispositivo, no se eliminan los mensajes de alarma de la pantalla (si están presentes en el enrutador) ni se apagan los LED de alarma. Además, las nuevas alarmas que se producen después de silenciar un dispositivo externo reactivan el dispositivo externo.
MX10003 enrutadores no admiten la interfaz CRAFT.
En la versión 11.1 y posteriores de Junos OS, las alarmas para ventiladores también muestran el número de ranura de los ventiladores en la salida de la CLI.
En Junos OS versión 11.2 y posteriores, el resultado del comando en los conmutadores EX8200 muestra la ubicación detallada (Plane/FPC/PFE
) para los errores de vínculo en el chasis.
En Junos OS versión 10.2 y posteriores, se muestra una alarma en los enrutadores de la serie T para un generador de reloj SONET (SCG) en espera que está fuera de línea o ausente.
A menudo puede ver los siguientes mensajes de error, en los que solo se muestra el código de error y no se proporciona ninguna otra información:
Apr 12 08:04:10 send: red alarm set, device FPC 6, reason FPC 6 Major Errors - Error code: 257 Apr 12 08:04:19 send: red alarm set, device FPC 1, reason FPC 1 Major Errors - Error code: 559
Para comprender qué significan CM_ALARM códigos de error, primero debe identificar la estructura de los códigos de alarma CM. Un código CM_ALARM tiene la siguiente estructura:
Bits: |
Tipo de error: |
1-31 |
Mayor (1) |
0 |
Menor (0) |
De acuerdo con la tabla anterior, el LSB (bit 0) identifica la Error Type (alarma mayor, si el bit está configurado y alarma menor si el bit no está configurado). El resto de los bits (1 - 31) identifican el código de error real.
Tomemos un ejemplo del siguiente código de error, que se registró en un T1600:
Apr 12 08:04:10 send: red alarm set, device FPC 1, reason FPC 1 Major Errors - Error code: 559
Primero, tienes que convertir 559 a binario; es decir 1000101111, . El LSB en este caso es 1, lo que significa que esta es una alarma importante. Después de quitar el LSB, se queda con 100010111, que es igual a 279 en decimal. Este es el código de error real, su significado se puede encontrar en la siguiente lista:
Chip Type: L Chip |
Code |
CMALARM_LCHIP_LOUT_DESRD_PARITY_ERR |
1 |
CMALARM_LCHIP_LOUT_DESRD_UNINIT_ERR |
2 |
CMALARM_LCHIP_LOUT_DESRD_ILLEGALLINK_ERR |
3 |
CMALARM_LCHIP_LOUT_DESRD_ILLEGALSIZE_ERR |
4 |
CMALARM_LCHIP_LOUT_HDRF_TOERR_ERR |
5 |
CMALARM_LCHIP_LOUT_HDRF_PARITY_ERR |
6 |
CMALARM_LCHIP_LOUT_HDRF_UCERR_ERR |
7 |
CMALARM_LCHIP_LOUT_NLIF_CRCDROP_ERR |
8 |
CMALARM_LCHIP_LOUT_NLIF_CRCERR_ERR |
9 |
CMALARM_LCHIP_UCODE_TIMEOUT_ERR |
10 |
CMALARM_LCHIP_LIN_SRCTL_ACCT_DROP_ERR |
11 |
CMALARM_LCHIP_LIN_SRCTL_ACCT_ADDR_SIZE_ERR |
12 |
CMALARM_LCHIP_SRAM_PARITY_ERR |
13 |
CMALARM_LCHIP_UCODE_OVFLW_ERR |
14 |
CMALARM_LCHIP_LOUT_HDRF_MTU_ERR |
15 |
Chip Type: M Chip |
Code |
CMALARM_MCHIP_ECC_UNCORRECT_ERR |
128 |
Chip Type: N Chip |
Code |
CMALARM_NCHIP_RDDMA_JBUS_TIMEOUT_ERR |
256 |
CMALARM_NCHIP_RDDMA_FIFO_OVFLW_ERR |
257 |
CMALARM_NCHIP_RDDMA_FIFO_UNFLW_ERR |
258 |
CMALARM_NCHIP_RDDMA_SIZE_ERR |
259 |
CMALARM_NCHIP_RDDMA_JBUS_CRC_ERR |
260 |
CMALARM_NCHIP_WRDMA_PKTR_ERR |
261 |
CMALARM_NCHIP_WRDMA_PKT_CRC_ERR |
262 |
CMALARM_NCHIP_WRDMA_JBUS_TIMEOUT_ERR |
263 |
CMALARM_NCHIP_WRDMA_FIFO_OVFLW_ERR |
264 |
CMALARM_NCHIP_WRDMA_FIFO_UNFLW_ERR |
265 |
CMALARM_NCHIP_WRDMA_PKT_LEN_ERR |
266 |
CMALARM_NCHIP_WRDMA_JBUS_CRC_ERR |
267 |
CMALARM_NCHIP_PKTR_DMA_AGE_ERR |
268 |
CMALARM_NCHIP_PKTR_ICELLSIG_ERR |
269 |
CMALARM_NCHIP_PKTR_FTTL_ERR |
270 |
CMALARM_NCHIP_RODR_OFFSET_OVFLW_ERR |
271 |
CMALARM_NCHIP_PKTR_TMO_CELL_ERR |
272 |
CMALARM_NCHIP_PKTR_TMO_OUTRANGE_ERR |
273 |
CMALARM_NCHIP_PKTR_MD_REQUEST_Q_OVFLW_ERR |
274 |
CMALARM_NCHIP_PKTR_DMA_BUFFER_OVFLW_ERR |
275 |
CMALARM_NCHIP_PKTR_GRT_OVFLW_ERR |
276 |
CMALARM_NCHIP_FRQ_ERR |
277 |
CMALARM_NCHIP_RODR_IN_Q_OVFLW_ERR |
278 |
CMALARM_NCHIP_DBUF_CRC_ERR |
279 |
Chip Type: R Chip |
Code |
CMALARM_RCHIP_SRAM_PARITY_ERR |
512 |
Chip Type: R Chip |
Code |
CMALARM_ICHIP_WO_DESRD_ID_ERR |
601 |
CMALARM_ICHIP_WO_DESRD_DATA_ERR |
602 |
CMALARM_ICHIP_WO_DESRD_OFLOW_ERR |
603 |
CMALARM_ICHIP_WO_HDRF_UCERR_ERR |
604 |
CMALARM_ICHIP_WO_HDRF_MTUERR_ERR |
605 |
CMALARM_ICHIP_WO_HDRF_PARITY_ERR |
606 |
CMALARM_ICHIP_WO_HDRF_TOERR_ERR |
607 |
CMALARM_ICHIP_WO_IP_CRC_ERR |
608 |
CMALARM_ICHIP_WO_IP_INTER_ERR |
609 |
CMALARM_ICHIP_WI_WAN_TIMEOUT_ERR |
625 |
CMALARM_ICHIP_WI_FAB_TIMEOUT_ERR |
626 |
CMALARM_ICHIP_RLDRAM_BIST_ERR |
630 |
CMALARM_ICHIP_SDRAM_BIST_ERR |
631 |
CMALARM_ICHIP_RLDRAM_PARITY_ERR |
632 |
CMALARM_ICHIP_SDRAM_UNCORRECT_ERR |
633 |
CMALARM_ICHIP_SDRAM_CORRECT_ERR |
634 |
CMALARM_ICHIP_FUSE_DONE_ERR |
635 |
De acuerdo con la tabla anterior, el 279 código de error corresponde a CMALARM_NCHIP_DBUF_CRC_ERR; esto significa que se vieron nuevos errores de CRC en el NCHIP de este FPC en particular, que es FPC según los registros.
Si no desea convertir decimal a binario y viceversa, puede utilizar el siguiente acceso directo:
Para alarmas importantes, el Actual Error Code = (Error Code - 1)/2, donde Error Code es el código que se obtiene en el mensaje de registro. Por ejemplo, si obtiene el siguiente registro:
Apr 12 08:04:10 send: red alarm set, device FPC 6, reason FPC 6 Major Errors - Error code: 257
Código de error real = (257-1)/2 = 128. Del mismo modo, para alarmas menores, Código de error real = (Código de error)/2
A partir de Junos OS versión 18.2R1, en los enrutadores de la serie MX, el show chassis alarms
resultado no muestra códigos de error para errores relacionados con PFE. Puede utilizar los siguientes comandos para ver más detalles de los errores que provocaron las alarmas:
-
show chassis errors active
-
show chassis errors active detail
Nivel de privilegio requerido
vista
Campos de salida
En la tabla 7 se enumeran los campos de salida del show chassis alarms
comando. Los campos de salida se enumeran en el orden aproximado en que aparecen.
Nombre del campo |
Descripción del campo |
---|---|
|
Fecha y hora en que se registró la alarma por primera vez. |
|
Clase de gravedad para esta alarma: |
|
Información sobre la alarma. |
Salida de muestra
- mostrar alarmas de chasis (Alarmas activas)
- mostrar alarmas de chasis (No hay alarmas activas)
- mostrar alarmas de chasis (bandeja de ventilador)
- mostrar alarmas de chasis (MX150)
- mostrar alarmas de chasis (enrutador MX104)
- mostrar alarmas de chasis (enrutador MX2010)
- mostrar alarmas de chasis (enrutador MX2020)
- mostrar alarmas de chasis (enrutador MX10003)
- mostrar alarmas de chasis (enrutador MX10004)
- mostrar alarmas de chasis (enrutador MX204)
- mostrar alarmas de chasis (enrutador MX2008)
- muestra alarmas de chasis (enrutadores MX960, MX480 y MX240 que muestran una falla importante de CB)
- mostrar alarmas de chasis (enrutador PTX10008)
- mostrar alarmas de chasis (enrutador T4000)
- mostrar alarmas de chasis (destinos inalcanzables presentes en un enrutador de la serie T)
- mostrar alarmas de chasis (FPC sin conexión debido a destinos inaccesibles en un enrutador de la serie T)
- mostrar alarmas de chasis (SCG ausente en un enrutador de la serie T)
- mostrar alarmas de chasis (Alarmas activas en un enrutador TX Matrix)
- mostrar alarmas de chasis (enrutador TX Matrix Plus con SIB 3D)
- mostrar alarmas de chasis (Alarmas en un enrutador T4000 después de habilitar la instrucción de modo mejorado)
- mostrar alarmas de chasis (motor de enrutamiento de reserva)
- mostrar alarmas de chasis (conmutador de la serie EX)
- mostrar alarmas de chasis (alarmas activas en los conmutadores serie QFX y OCX)
- mostrar dispositivo de nodo de alarmas de chasis (Alarmas activas en el sistema QFabric)
- mostrar alarmas de chasis (Alarmas activas en el sistema QFabric)
- mostrar alarmas de chasis (alarmas activas en un conmutador EX8200)
- mostrar alarmas de chasis (conmutador EX9251)
- mostrar alarmas de chasis (conmutador EX9253)
- mostrar alarmas de chasis (serie MX para restablecimiento de PFE)
- muestra las alarmas del chasis (serie MX para error de restablecimiento de PFE)
mostrar alarmas de chasis (Alarmas activas)
user@host> show chassis alarms 3 alarms are currently active Alarm time Class Description 2000-02-07 10:12:22 UTC Major fxp0: ethernet link down 2000-02-07 10:11:54 UTC Minor YELLOW ALARM - PEM 1 Removed 2000-02-07 10:11:03 UTC Minor YELLOW ALARM - Lower Fan Tray Removed
mostrar alarmas de chasis (No hay alarmas activas)
user@host> show chassis alarms No alarms are currently active
mostrar alarmas de chasis (bandeja de ventilador)
user@host> show chassis alarms 4 alarms currently active Alarm time Class Description 2010-11-11 20:27:38 UTC Major Side Fan Tray 7 Failure 2010-11-11 20:27:13 UTC Minor Side Fan Tray 7 Overspeed 2010-11-11 20:27:13 UTC Major Side Fan Tray 5 Failure 2010-11-11 20:27:13 UTC Major Side Fan Tray 0 Failure
mostrar alarmas de chasis (MX150)
user@host > show chassis alarms 1 alarms currently active Alarm time Class Description 2016-06-04 01:49:43 PDT Major Fan Tray 1 Fan 0 failed
mostrar alarmas de chasis (enrutador MX104)
user@host >show chassis alarms 1 alarms currently active Alarm time Class Description 2013-06-05 14:43:31 IST Minor Backup RE Active
mostrar alarmas de chasis (enrutador MX2010)
user@host> show chassis alarms 7 alarms currently active Alarm time Class Description 2012-08-07 00:46:06 PDT Major Fan Tray 2 Failure 2012-08-06 18:24:36 PDT Minor Redundant feed missing for PSM 6 2012-08-06 07:41:04 PDT Minor Redundant feed missing for PSM 8 2012-08-04 02:42:06 PDT Minor Redundant feed missing for PSM 5 2012-08-03 21:14:24 PDT Minor Loss of communication with Backup RE 2012-08-03 12:26:03 PDT Minor Redundant feed missing for PSM 4 2012-08-03 10:40:18 PDT Minor Redundant feed missing for PSM 7
mostrar alarmas de chasis (enrutador MX2020)
user@host> show chassis alarms 1 alarms currently active Alarm time Class Description 2012-10-03 12:14:59 PDT Minor Plane 0 not online
mostrar alarmas de chasis (enrutador MX10003)
user@host> show chassis alarms 9 alarms currently active Alarm time Class Description 2017-07-13 21:50:31 PDT Major FPC 1 Temperature Hot 2017-07-13 21:50:04 PDT Minor FPC 1 PIC 1 Invalid port profile configuration 2017-07-13 21:49:13 PDT Minor FPC 1 PIC 0 Invalid port profile configuration 2017-07-13 21:48:54 PDT Major FPC 0 Temperature Hot 2017-07-13 21:43:54 PDT Minor CB 1 Voltage Sensor ADS7830_0x4B Sensor Failed 2017-07-13 21:43:54 PDT Minor CB 0 Voltage Sensor ADS7830_0x4B Sensor Failed 2017-07-13 21:43:31 PDT Minor Loss of communication with Backup RE
A partir de Junos OS versión 19.2R1, los enrutadores MX10003 no emiten una alarma si una ranura del módulo de entrada de energía (PEM) está vacía. Sin embargo, cuando el número de PEM operativos es inferior a 2, el enrutador activa una alarma importante. Esta alarma se borra cuando se dispone del número requerido de PEM.
mostrar alarmas de chasis (enrutador MX10004)
user@host> show chassis alarms 2 alarms currently active Alarm time Class Description 2022-07-05 20:34:40 PDT Major Fan Tray 0 EEPROM Read Error 2021-17-05 11:06:47 PST Minor Check plane 0 Fabric Chip
user@host> show chassis alarms | match PEM 2021-11-12 13:19:35 UTC Major PEM 2 Not Supported
user@host> show system alarms | match Fan 2021-09-27 19:13:15 PDT Major Fan Tray 0 Model Not Supported
mostrar alarmas de chasis (enrutador MX204)
user@host> show chassis alarms 1 alarms currently active Alarm time Class Description 2017-11-05 22:13:03 PST Major PEM 0 Not Present
mostrar alarmas de chasis (enrutador MX2008)
user@host>show chassis alarms No alarms currently active
muestra alarmas de chasis (enrutadores MX960, MX480 y MX240 que muestran una falla importante de CB)
Se produce una alarma de fallo CB 0 importante en caso de un CB defectuoso (los CB desconocidos o no coincidentes no activan esta alarma en Junos versión OS 12.3R9 y posteriores). Después de GRES o recuperación, si el problema de hardware persiste, el tráfico se mueve al CB bueno y continúa. Si la alarma fue activada por algo transitorio como un presupuesto de zona de energía en GRES, volver a poner el CB en línea puede borrar la alarma. De lo contrario, reemplace el CB defectuoso. Tenga en cuenta que la velocidad del vínculo de estructura no se ve afectada por un SCB sin conexión. La alarma se activará en CB0, CB1 y CB2.
user@host> show chassis alarms 6 alarms currently active Alarm time Class Description 2014-10-31 16:49:41 EDT Major PEM 3 Not OK 2014-10-31 16:49:41 EDT Major PEM 2 Not OK 2014-10-31 16:49:31 EDT Major CB 0 Failure 2014-10-31 16:49:31 EDT Minor CB 0 Fabric Chip 0 Not Online 2014-10-31 16:49:31 EDT Minor CB 0 Fabric Chip 1 Not Online 2014-10-31 16:49:31 EDT Minor Backup RE Active
mostrar alarmas de chasis (enrutador PTX10008)
user@host>show chassis alarms 12 alarms currently active Alarm time Class Description 2017-05-09 01:38:55 PDT Minor Loss of communication with Backup RE 2017-05-05 06:49:57 PDT Major FPC 5 LCPU Temp Sensor Access Failed 2017-05-05 06:49:57 PDT Major FPC 5 PE2 Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 PE1 Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 PE0 Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 Exhaust-C Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 Exhaust-B Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 Exhaust-A Temp Sensor Hot 2017-05-05 06:49:57 PDT Major FPC 5 Intake-B Temp Sensor Access Failed 2017-05-05 06:49:57 PDT Major FPC 5 Intake-A Temp Sensor Access Failed 2017-05-05 06:49:57 PDT Major Fan Tray 0 Fan 5 running at lower speed 2017-05-05 06:49:57 PDT Major Fan Tray 0 Fan 4 running at lower speed
mostrar alarmas de chasis (enrutador T4000)
user@host> show chassis alarms 9 alarms currently active Alarm time Class Description 2007-06-02 01:41:10 UTC Minor RE 0 Not Supported 2007-06-02 01:41:10 UTC Minor CB 0 Not Supported 2007-06-02 01:41:10 UTC Minor Mixed Master and Backup RE types 2007-05-30 19:37:33 UTC Major SPMB 1 not online 2007-05-30 19:37:29 UTC Minor Front Bottom Fan Tray Absent 2007-05-30 19:37:13 UTC Major PEM 1 Input Failure 2007-05-30 19:37:13 UTC Major PEM 0 Not OK 2007-05-30 19:37:03 UTC Major PEM 0 Improper for Platform 2007-05-30 19:37:03 UTC Minor Backup RE Active
mostrar alarmas de chasis (destinos inalcanzables presentes en un enrutador de la serie T)
user@host> show chassis alarms 10 alarms currently active Alarm time Class Description 2011-08-30 18:43:53 PDT Major FPC 7 has unreachable destinations 2011-08-30 18:43:53 PDT Major FPC 5 has unreachable destinations 2011-08-30 18:43:52 PDT Major FPC 3 has unreachable destinations 2011-08-30 18:43:52 PDT Major FPC 2 has unreachable destinations 2011-08-30 18:43:52 PDT Minor SIB 0 Not Online 2011-08-30 18:43:33 PDT Minor SIB 4 Not Online 2011-08-30 18:43:28 PDT Minor SIB 3 Not Online 2011-08-30 18:43:05 PDT Minor SIB 2 Not Online 2011-08-30 18:43:28 PDT Minor SIB 1 Not Online 2011-08-30 18:43:05 PDT Major PEM 1 Not Ok
mostrar alarmas de chasis (FPC sin conexión debido a destinos inaccesibles en un enrutador de la serie T)
user@host> show chassis alarms 10 alarms currently active Alarm time Class Description 2011-08-30 18:43:53 PDT Major FPC 7 offline due to unreachable destinations 2011-08-30 18:43:53 PDT Major FPC 5 offline due to unreachable destinations 2011-08-30 18:43:52 PDT Major FPC 3 offline due to unreachable destinations 2011-08-30 18:43:52 PDT Major FPC 2 offline due to unreachable destinations 2011-08-30 18:43:52 PDT Minor SIB 0 Not Online 2011-08-30 18:43:33 PDT Minor SIB 4 Not Online 2011-08-30 18:43:28 PDT Minor SIB 3 Not Online 2011-08-30 18:43:05 PDT Minor SIB 2 Not Online 2011-08-30 18:43:28 PDT Minor SIB 1 Not Online 2011-08-30 18:43:05 PDT Major PEM 1 Not Ok
mostrar alarmas de chasis (SCG ausente en un enrutador de la serie T)
user@host> show chassis alarms 4 alarms currently active Alarm time Class Description 2011-01-23 21:42:46 PST Major SCG 0 NO EXT CLK MEAS-BKUP SCG ABS
mostrar alarmas de chasis (Alarmas activas en un enrutador TX Matrix)
user@host> show chassis alarms scc-re0: -------------------------------------------------------------------------- 8 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor LCC 0 Minor Errors 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:52 PDT Major SIB 2 Absent 2004-08-05 18:43:52 PDT Major SIB 1 Absent 2004-08-05 18:43:52 PDT Major SIB 0 Absent 2004-08-05 18:43:33 PDT Major LCC 2 Major Errors 2004-08-05 18:43:28 PDT Major LCC 0 Major Errors 2004-08-05 18:43:05 PDT Minor LCC 2 Minor Errors lcc0-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:49 PDT Major SIB 2 Absent 2004-08-05 18:43:49 PDT Major SIB 1 Absent 2004-08-05 18:43:49 PDT Major SIB 0 Absent 2004-08-05 18:43:28 PDT Major PEM 0 Not OK lcc2-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:35 PDT Minor SIB 3 Not Online 2004-08-05 18:43:33 PDT Major SIB 2 Absent 2004-08-05 18:43:33 PDT Major SIB 1 Absent 2004-08-05 18:43:33 PDT Major SIB 0 Absent 2004-08-05 18:43:05 PDT Minor PEM 1 Absent
mostrar alarmas de chasis (enrutador TX Matrix Plus con SIB 3D)
user@host> show chassis alarms sfc0-re0: -------------------------------------------------------------------------- Alarm time Class Description 2014-04-08 14:35:13 IST Minor FPM 0 SFC Config Size Changed 2014-04-08 14:32:58 IST Major Fan Tray Failure 2014-04-08 14:31:53 IST Major SIB F13 6 Fault 2014-04-08 14:31:43 IST Major SIB F13 11 Fault 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 14 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 8 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 3 Fbr Cbl 2014-04-08 14:31:08 IST Major SIB F13 12 CXP 15 fault 2014-04-08 14:31:08 IST Minor SIB F13 12 CXP 14 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 14 2014-04-08 14:31:08 IST Major SIB F13 12 CXP 10 fault 2014-04-08 14:31:08 IST Minor SIB F13 12 CXP 8 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 8 2014-04-08 14:31:08 IST Major SIB F13 12 CXP 7 fault 2014-04-08 14:31:08 IST Major SIB F13 12 CXP 4 fault 2014-04-08 14:31:08 IST Minor SIB F13 12 CXP 3 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 12 CXP 3 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 14 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 12 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 8 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 6 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 4 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 2 Fbr Cbl 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 0 Fbr Cbl 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 14 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 14 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 12 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 12 2014-04-08 14:31:08 IST Major SIB F13 6 CXP 10 fault 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 8 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 8 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 6 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 6 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 4 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 4 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 2 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 2 2014-04-08 14:31:08 IST Minor SIB F13 6 CXP 0 LOL 2014-04-08 14:31:08 IST Minor Check SIB F13 6 CXP 0 2014-04-08 14:31:08 IST Minor SIB F13 12 CXP 14 XC HSL Link Error 2014-04-08 14:29:27 IST Minor LCC 0 Minor Errors 2014-04-08 14:28:37 IST Major LCC 0 Major Errors 2014-04-08 14:28:37 IST Major LCC 2 Major Errors 2014-04-08 14:28:37 IST Minor LCC 2 Minor Errors 2014-04-08 14:28:24 IST Major SIB F2S 4/6 Absent 2014-04-08 14:28:24 IST Major SIB F2S 4/4 Absent 2014-04-08 14:28:24 IST Major SIB F2S 4/2 Absent 2014-04-08 14:28:24 IST Major SIB F2S 4/0 Absent 2014-04-08 14:28:24 IST Major SIB F2S 3/6 Absent 2014-04-08 14:28:24 IST Major SIB F2S 3/4 Absent 2014-04-08 14:28:24 IST Major SIB F2S 3/2 Absent 2014-04-08 14:28:24 IST Major SIB F2S 3/0 Absent 2014-04-08 14:28:24 IST Major SIB F13 9 Absent 2014-04-08 14:28:24 IST Major SIB F13 8 Absent 2014-04-08 14:28:24 IST Major SIB F13 7 Absent 2014-04-08 14:28:24 IST Major SIB F13 4 Absent 2014-04-08 14:28:24 IST Major SIB F13 1 Absent 2014-04-08 14:28:22 IST Major PEM 0 Input Failure 2014-04-08 14:28:22 IST Major PEM 0 Not OK lcc0-re0: -------------------------------------------------------------------------- 12 alarms currently active Alarm time Class Description 2014-04-08 14:36:08 IST Minor CB 1 M/S Switch Changed 2014-04-08 14:36:08 IST Minor CB 1 CHASSIS ID Changed 2014-04-08 14:35:43 IST Minor CB 0 M/S Switch Changed 2014-04-08 14:35:43 IST Minor CB 0 CHASSIS ID Changed 2014-04-08 14:29:30 IST Minor SIB 4 Not Online 2014-04-08 14:29:30 IST Minor SIB 3 Not Online 2014-04-08 14:29:30 IST Minor SIB 2 Not Online 2014-04-08 14:29:24 IST Major Rear Fan Tray Failure 2014-04-08 14:29:24 IST Major Front Bottom Fan Tray Improper for Platform 2014-04-08 14:29:24 IST Major Front Top Fan Tray Improper for Platform 2014-04-08 14:28:37 IST Major SIB 4 Absent 2014-04-08 14:28:37 IST Major SIB 3 Absent lcc2-re0: -------------------------------------------------------------------------- 12 alarms currently active Alarm time Class Description 2014-04-08 14:36:02 IST Minor CB 1 M/S Switch Changed 2014-04-08 14:36:02 IST Minor CB 1 CHASSIS ID Changed 2014-04-08 14:35:42 IST Minor CB 0 M/S Switch Changed 2014-04-08 14:34:42 IST Minor CB 0 CHASSIS ID Changed 2014-04-08 14:29:29 IST Minor SIB 0 CXP 7 Unsupported Optics 2014-04-08 14:29:27 IST Major Front Bottom Fan Tray Improper for Platform 2014-04-08 14:29:27 IST Major Front Top Fan Tray Improper for Platform 2014-04-08 14:29:25 IST Minor SIB 4 Not Online 2014-04-08 14:29:25 IST Minor SIB 3 Not Online 2014-04-08 14:28:47 IST Major PEM 0 Not OK 2014-04-08 14:28:36 IST Major SIB 2 Absent 2014-04-08 14:28:36 IST Minor Host 0 Boot from alternate media lcc6-re0: -------------------------------------------------------------------------- 2 alarms currently active Alarm time Class Description 2013-11-06 04:03:56 PST Minor SIB 1 CXP 0 XC HSL Link Error 2013-11-06 03:49:32 PST Major PEM 1 Not OK
mostrar alarmas de chasis (Alarmas en un enrutador T4000 después de habilitar la instrucción de modo mejorado)
Para habilitar un aprendizaje mejorado de dirección MAC del servicio de LAN privada virtual (VPLS) en enrutadores T4000, debe incluir la enhanced-mode
instrucción en el nivel de [edit chassis network-services]
jerarquía y reiniciar el enrutador. Cuando el enrutador se reinicia, solo se requiere que los FPC T4000 Tipo 5 estén presentes en el enrutador. Si hay otras FPC (aparte de las FPC T4000 Tipo 5) en el enrutador T4000, dichas FPC se desconectarán y se generarán alarmas de configuración incorrecta de FPC. La show chassis alarm
salida del comando muestra una configuración incorrecta de FPC (FPC fpc-slot misconfig
) como el motivo de la generación de las alarmas.
user@host> show chassis alarms 2 alarms currently active Alarm time Class Description 2011-10-22 10:10:47 PDT Major FPC 1 misconfig 2011-10-22 10:10:46 PDT Major FPC 0 misconfig
mostrar alarmas de chasis (motor de enrutamiento de reserva)
user@host> show chassis alarms 2 alarms are currently active Alarm time Class Description 2005-04-07 10:12:22 PDT Minor Host 1 Boot from alternate media 2005-04-07 10:11:54 PDT Major Host 1 compact-flash missing in Boot List
mostrar alarmas de chasis (conmutador de la serie EX)
user@switch> show chassis alarms 4 alarms currently active Alarm time Class Description 2014-03-12 15:36:09 UTC Minor Require a Fan Tray upgrade 2014-03-12 15:00:02 UTC Major PEM 0 Input Failure 2014-03-12 15:00:02 UTC Major PEM 0 Not OK 2014-03-12 14:59:51 UTC Minor Host 1 Boot from alternate media
mostrar alarmas de chasis (alarmas activas en los conmutadores serie QFX y OCX)
user@switch> show chassis alarms 1 alarms currently active Alarm time Class Description 2012-03-05 2:10:24 UTC Major FPC 0 PEM 0 Airflow not matching Chassis Airflow
mostrar dispositivo de nodo de alarmas de chasis (Alarmas activas en el sistema QFabric)
user@switch> show chassis alarms node-device Test node-device ED3694 3 alarms currently active Alarm time Class Description 2011-08-24 16:04:15 UTC Major Test:fte-0/1/2: Link down 2011-08-24 16:04:14 UTC Major Test:fte-0/1/0: Link down 2011-08-24 14:21:14 UTC Major Test PEM 0 is not supported/powered
mostrar alarmas de chasis (Alarmas activas en el sistema QFabric)
user@switch> show chassis alarms IC-1: -------------------------------------------------------------------------- 1 alarms currently active Alarm time Class Description 2011-08-24 16:04:15 UTC Minor Backup RE Active Test: -------------------------------------------------------------------------- 3 alarms currently active Alarm time Class Description 2011-08-24 16:04:15 UTC Major Test:fte-0/1/2: Link down 2011-08-24 16:04:14 UTC Major Test:fte-0/1/0: Link down 2011-08-24 14:21:14 UTC Major Test PEM 0 is not supported/powered SNG-0: -------------------------------------------------------------------------- NW-NG-0: -------------------------------------------------------------------------- 1 alarms currently active Alarm time Class Description 2011-08-24 15:49:27 UTC Major Test PEM 0 is not supported/powered
mostrar alarmas de chasis (alarmas activas en un conmutador EX8200)
user@switch> show chassis alarms 6 alarms currently active Alarm time Class Description 2010-12-02 19:15:22 UTC Major Fan Tray Failure 2010-12-02 19:15:22 UTC Major Fan Tray Failure 2010-12-02 19:15:14 UTC Minor Check CB 0 Fabric Chip 1 on Plane/FPC/PFE: 1/5/0, 1/5/1, 1/5/2, 1/5/3, 1/7/0, 1/7/1, 1/7/2, 1/7/3, 2/5/0, 2/5/1, ... 2010-12-02 19:15:14 UTC Minor Check CB 0 Fabric Chip 0 on Plane/FPC/PFE: 1/5/0, 1/5/1, 1/5/2, 1/5/3, 1/7/0, 1/7/1, 1/7/2, 1/7/3, 2/5/0, 2/5/1, ... 2010-12-02 19:14:18 UTC Major PSU 1 Output Failure 2010-12-02 19:14:18 UTC Minor Loss of communication with Backup RE
mostrar alarmas de chasis (conmutador EX9251)
user@switch> show chassis alarms 2 alarms currently active Alarm time Class Description 2018-03-08 05:13:10 PST Major PEM 0 Not Powered 2018-03-08 05:13:10 PST Major Fan Tray 2 is not present
mostrar alarmas de chasis (conmutador EX9253)
user@switch> show chassis alarms 6 alarms currently active Alarm time Class Description 2018-03-07 01:09:01 PST Major Power Budget:Insufficient Power 2018-03-06 23:56:34 PST Minor Loss of communication with Backup RE 2018-02-15 00:48:10 PST Minor PEM 3 Not Present 2018-02-15 00:48:10 PST Minor PEM 2 Not Present 2018-02-15 00:48:07 PST Major PEM 4 Not Powered 2018-02-15 00:48:07 PST Major PEM 1 Not Powered
mostrar alarmas de chasis (serie MX para restablecimiento de PFE)
user@host> show chassis alarms 1 alarm currently active Alarm time Class Description 2021-01-04 11:20:42 PST Major FPC 0 PFE 0 reset initiated
muestra las alarmas del chasis (serie MX para error de restablecimiento de PFE)
user@host> show chassis alarms 1 alarm currently active Alarm time Class Description 2021-01-04 11:20:42 PST Major FPC 0 PFE 0 reset error
- mostrar alarmas de chasis (alarmas activas en un enrutador de transporte de paquetes PTX5000)
- mostrar alarmas de chasis (combinación de alarma de PDU en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
- mostrar alarmas de chasis (Alarma fallida del convertidor de PDU en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
- mostrar alarmas de chasis (sin alimentación para la alarma del sistema en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
- mostrar alarmas de chasis (Alarmas activas en un enrutador universal para redes metropolitanas ACX2000)
- mostrar alarmas de chasis (alarma activa para indicar el estado del reloj SCB defectuoso en la serie MX)
- mostrar alarmas de chasis (alarmas activas en un enrutador de transporte de paquetes PTX1000)
- mostrar alarmas de chasis (enrutador MX10003)
- mostrar alarmas de chasis (alarmas activas en un enrutador MX10008)
- mostrar alarmas de chasis (serie ACX)
mostrar alarmas de chasis (alarmas activas en un enrutador de transporte de paquetes PTX5000)
user@host> show chassis alarms 23 alarms currently active Alarm time Class Description 2011-07-12 16:22:05 PDT Minor No Redundant Power for Rear Chassis 2011-07-12 16:22:05 PDT Major PDU 0 PSM 1 Not OK 2011-07-12 16:21:57 PDT Minor No Redundant Power for Fan 0-2 2011-07-12 16:21:57 PDT Major PDU 0 PSM 0 Not OK 2011-07-12 15:56:06 PDT Major PDU 1 PSM 2 Not OK 2011-07-12 15:56:06 PDT Minor No Redundant Power for FPC 0-7 2011-07-12 15:56:06 PDT Major PDU 0 PSM 3 Not OK 2011-07-12 15:28:20 PDT Major PDU 0 PSM 2 Not OK 2011-07-12 15:19:14 PDT Minor Backup RE Active
mostrar alarmas de chasis (combinación de alarma de PDU en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
Todas las PDU instaladas en un enrutador PTX5000 deben ser del mismo tipo. La Mix of PDUs
alarma o Power Manager Non Operational
se activa cuando se instalan diferentes tipos de PDU en un enrutador PTX5000.
user@host> show chassis alarms 15 alarms currently active Alarm time Class Description 2013-03-19 23:03:53 PDT Minor No Redundant Power 2013-03-19 23:03:48 PDT Minor Mix of PDUs 2013-03-19 23:03:47 PDT Minor PDU 1 PSM 3 Absent 2013-03-19 23:03:47 PDT Minor PDU 1 PSM 2 Absent 2013-03-19 23:03:47 PDT Minor PDU 1 PSM 1 Absent 2013-03-19 23:03:47 PDT Minor PDU 1 PSM 0 Absent 2013-03-19 23:03:46 PDT Major No CG Online
mostrar alarmas de chasis (Alarma fallida del convertidor de PDU en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
La PDU Converter Failed
alarma se activa cuando falla uno o más convertidores de amplificador de 36 V de una PDU de CC. Si dos o más convertidores de amplificador de 36 V fallan, las bandejas del ventilador fallan y el enrutador podría sobrecalentarse. Por lo tanto, cuando se active esta alarma, verifique la PDU y reemplácela, si es necesario.
user@host> show chassis alarms 11 alarms currently active Alarm time Class Description 2013-12-11 22:14:13 PST Minor No Redundant Power for System 2013-12-11 22:14:10 PST Major PDU 0 PSM 7 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 6 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 5 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 4 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 3 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 2 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 1 Not OK 2013-12-11 22:14:10 PST Major PDU 0 PSM 0 Not OK 2013-12-11 22:14:10 PST Major PDU 0 Not OK 2013-12-11 22:14:01 PST Major PDU 0 Converter Failed
mostrar alarmas de chasis (sin alimentación para la alarma del sistema en un enrutador de transporte de paquetes PTX5000 con FPC2-PTX-P1A)
user@host> show chassis alarms 8 alarms currently active Alarm time Class Description 2013-11-19 01:58:41 PST Major No Power for System 2013-11-19 01:58:37 PST Major PDU 0 PSM 1 Not OK 2013-11-19 01:56:46 PST Major PDU 0 PSM 2 Not OK 2013-11-19 01:54:26 PST Major PDU 0 PSM 3 Not OK 2013-11-19 01:53:30 PST Major PDU 1 PSM 3 Not OK 2013-11-19 01:53:29 PST Major PDU 1 PSM 2 Not OK 2013-11-19 01:53:29 PST Major PDU 1 PSM 1 Not OK 2013-11-19 01:53:29 PST Major PDU 1 PSM 0 Not OK
mostrar alarmas de chasis (Alarmas activas en un enrutador universal para redes metropolitanas ACX2000)
user@host> show chassis alarms 7 alarms currently active Alarm time Class Description 2012-05-22 11:19:09 UTC Major xe-0/3/1: Link down 2012-05-22 11:19:09 UTC Major xe-0/3/0: Link down 2012-05-22 11:19:09 UTC Major ge-0/1/7: Link down 2012-05-22 11:19:09 UTC Major ge-0/1/6: Link down 2012-05-22 11:19:09 UTC Major ge-0/1/3: Link down 2012-05-22 11:19:09 UTC Major ge-0/1/2: Link down 2012-05-22 11:19:09 UTC Major ge-0/1/1: Link down
mostrar alarmas de chasis (alarma activa para indicar el estado del reloj SCB defectuoso en la serie MX)
user@host> show chassis alarms 1 alarm currently active Alarm time Class Description 2013-08-06 07:48:35 PDT Major CB 0 19.44 MHz clock failure
mostrar alarmas de chasis (alarmas activas en un enrutador de transporte de paquetes PTX1000)
user@host> show chassis alarms 2 alarms currently active Alarm time Class Description 2004-08-10 00:55:49 UTC Major PEM 1 Not Present 2004-08-10 00:55:49 UTC Major PEM 0 Not Present
mostrar alarmas de chasis (enrutador MX10003)
Si LCMD está inactivo en el RE de respaldo, se verá la siguiente alarma en el principal.
user@host> show chassis alarms 1 alarm currently active Alarm time Class Description 2017-05-09 13:26:27 PDT Major VMHost RE 1 host application failed
Si LCMD está inactivo en la página principal, se muestran las siguientes alarmas.
user@host> show chassis alarms 3 alarms currently active Alarm time Class Description 2017-05-10 14:12:21 PDT Major VMHost RE 0 host application failed 2017-05-10 14:12:16 PDT Minor LCM Peer Absent 2017-05-09 13:26:27 PDT Major VMHost RE 1 host application failed
Si el proceso LCMD se bloquea en el principal, el sistema cambiará después de un minuto, siempre que la conexión LCMD de RE de respaldo sea estable. El sistema no cambiará bajo las siguientes condiciones: si la conexión LCMD de RE de respaldo es inestable o si el primario actual acaba de ganar el rol principal. Cuando el principal acaba de adquirir el rol principal, el cambio ocurre solo después de cuatro minutos.
La alarma de inestabilidad de conexión del par LCM se activa cuando la comunicación LCMD-CHASD IPC se activa tres veces en un pequeño intervalo de dos a tres minutos. Una vez que se activa la alarma de no estable de conexión del par LCM, el estado de la conexión se supervisa durante dos minutos.
user@host> show chassis alarms 7 alarms currently active Alarm time Class Description 2017-05-29 10:12:17 PDT Minor LCM Peer Connection un-stable 2017-05-29 09:04:17 PDT Minor PEM 8 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 9 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 7 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 3 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 0 Not Powered 2017-05-29 09:04:08 PDT Minor Loss of communication with Backup RE
Si no hay más aletas de conexión dentro de este intervalo de tiempo de dos minutos, se borra la alarma de no estable de conexión del par LCM.
6 alarms currently active Alarm time Class Description 2017-05-29 09:04:17 PDT Minor PEM 8 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 9 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 7 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 3 Not Powered 2017-05-29 09:04:17 PDT Minor PEM 0 Not Powered 2017-05-29 09:04:08 PDT Minor Loss of communication with Backup RE
Se activa una alarma importante incluso si hay un error de bloqueo PLL, y esta alarma solo se puede borrar mediante un reinicio de FPC.
user@host> show chassis alarms 4 alarms currently active Alarm time Class Description 2017-02-16 09:06:06 PDT Major FPC 0 Major Errors 2017-02-16 09:08:40 PDT Major FPC 1 Major Errors 2017-02-16 09:11:47 PST Minor Fan Tray 3 Pair 1 Outer Fan running at over speed 2017-02-16 09:11:47 PST Minor Fan Tray 3 Pair 1 Inner Fan running at over speed
mostrar alarmas de chasis (alarmas activas en un enrutador MX10008)
user@host> show chassis alarms 13 alarms currently active Alarm time Class Description 2018-07-17 05:48:08 PDT Major FPC 2 I2C Failure 2018-07-17 05:47:02 PDT Minor Mixed Master and Backup RE types 2018-07-17 05:47:01 PDT Major Fan Tray 0 Fan 5 Failed 2018-07-17 05:47:01 PDT Major Fan Tray 0 Fan 4 Failed 2018-07-17 05:47:01 PDT Minor PEM 5 Not Powered 2018-07-17 05:47:01 PDT Minor PEM 5 Feed 2 has no input source 2018-07-17 05:47:01 PDT Minor PEM 5 Feed 1 has no input source 2018-07-17 05:47:01 PDT Minor PEM 4 Not Powered 2018-07-17 05:47:01 PDT Minor PEM 4 Feed 2 has no input source 2018-07-17 05:47:01 PDT Minor PEM 4 Feed 1 has no input source 2018-07-17 05:47:01 PDT Minor PEM 3 Not Powered 2018-07-17 05:47:01 PDT Minor PEM 3 Feed 2 has no input source 2018-07-17 05:47:01 PDT Minor PEM 3 Feed 1 has no input source 2018-07-17 05:47:01 PDT Major CB 0 external-1 LOS
mostrar alarmas de chasis (serie ACX)
user@host> show chassis alarms Alarm time Class Description 2011-01-23 21:42:46 PST Major PTP Local Clock OOS 2011-01-23 21:42:46 PST Major PTP No Foreign Master 2011-01-23 21:42:46 PST Major Chassis Loss of all Equipment Clock Synch References 2011-01-23 21:42:46 PST Major Chassis Loss of Equipment Clock Synch Reference 1 2011-01-23 21:42:46 PST Major Chassis Loss of Equipment Clock Synch Reference 2 2011-01-23 21:42:46 PST Major Equipment Clock QL Below Threshold 2011-01-23 21:42:46 PST Major TOD Input A Signal Fail 2011-01-23 21:42:46 PST Major 1PPS lost 2011-01-23 21:42:46 PST Major SyncE Port incompatible Media Type
mostrar alarmas de chasis (MX10008, MX10016, PTX10008, PTX10016, QFX10008 QFX10016) (versión Junos OS)
Al iniciar la versión 21.2R1 de Junos OS Evolved, si se detecta un fallo de PEM o FET, se activa una alarma importante y el PSM identificado se apagará o generará alarmas según la configuración predefinida en el set chassis thermal-events fet-failure-check
comando.
Para la detección y acción de fallas de FET, la show chassis alarm
salida muestra una alarma importante e información si PSM está apagado.
Por ejemplo, para la show chassis
configuración:
user@root> show chassis thermal-health-check { fet-failure-check; action-onfail auto-shutdown; }
El resultado se muestra de la siguiente manera:
user@root> show chassis alarms Alarm time Class Description 2007-04-10 02:33:11 PDT Minor No Redundant Power for System 2007-04-10 02:33:08 PDT Minor PDU 1 PSM 4 Thermal Check brought it Down 2007-04-10 02:33:08 PDT Major PDU 1 PSM 4 Not OK 2007-04-10 02:33:08 PDT Minor PDU 0 PSM 4 Thermal Check brought it Down 2007-04-10 02:33:08 PDT Major PDU 0 PSM 4 Not OK 2007-04-10 02:32:03 PDT Minor PDU 1 PSM 3 Thermal Check brought it Down 2007-04-10 02:32:03 PDT Major PDU 1 PSM 3 Not OK ... ...
Mostrar alarmas de chasis (ACX7024)
En ACX7024 dispositivo, cuando edit chassis pem minimum
se establece en 1, se muestra el siguiente resultado. La alarma de ausencia de PSM se elimina solo después de un reinicio:
user@root> show chassis alarms 4 alarms currently active Alarm time Class Description 2022-05-15 09:12:31 PDT Major No Redundant Power for System 2022-05-15 09:12:31 PDT Major PSM 1 Input1 Failed 2022-05-15 09:12:31 PDT Major PSM 1 Input Failed 2022-05-15 09:12:34 PDT Major PSM 0 Absent 2022-06-04 05:30:11 PDT Minor RE 0 Secure boot disabled or not enforced
Cuando el modo de redundancia PSU 1+1 predeterminado está activo, se muestra el siguiente resultado:
user@root> show chassis alarms 6 alarms currently active Alarm time Class Description 2022-05-15 09:12:31 PDT Major No Redundant Power for System 2022-05-15 09:12:31 PDT Major PSM 1 Input1 Failed 2022-05-15 09:12:31 PDT Major PSM 1 Input Failed 2022-06-04 05:30:19 PDT Major PSM 0 Absent 2022-06-04 05:30:11 PDT Minor RE 0 Secure boot disabled or not enforced 2022-06-04 05:31:54 PDT Major chassis No Redundant Power
Información de la versión
Comando introducido antes de la versión 7.4 de Junos OS.
sfc
opción introducida en Junos OS versión 9.6 para el enrutador TX Matrix Plus.
satellite
opción introducida en Junos OS versión 14.2R3 para Junos Fusion.
Comando introducido en Junos OS versión 18.2R1 para conmutadores EX9253 y plataformas de enrutamiento universal MX10008.