show chassis cluster information
구문
show chassis cluster information
설명
섀시 클러스터 메시지를 표시합니다. 메시지는 각 노드의 상태와 모니터링된 장애의 세부 정보를 나타냅니다.
필수 권한 수준
보기
출력 필드
표 1 에는 명령의 출력 필드가 나열됩니다 show chassis cluster information
. 출력 필드가 나타나는 대략적 순서로 나열됩니다.
필드 이름 |
필드 설명 |
---|---|
|
섀시 클러스터의 노드( |
|
|
|
|
샘플 출력
섀시 클러스터 정보를 보여 주십시오.
user@host> show chassis cluster information node0: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: primary, Weight: 255 Time From To Reason Mar 27 17:44:19 hold secondary Hold timer expired Mar 27 17:44:27 secondary primary Better priority (200/200) Redundancy Group 1 , Current State: primary, Weight: 255 Time From To Reason Mar 27 17:44:19 hold secondary Hold timer expired Mar 27 17:44:27 secondary primary Remote yield (0/0) Redundancy Group 2 , Current State: secondary, Weight: 255 Time From To Reason Mar 27 17:44:19 hold secondary Hold timer expired Mar 27 17:44:27 secondary primary Remote yield (0/0) Mar 27 17:50:24 primary secondary-hold Preempt/yield(100/200) Mar 27 17:50:25 secondary-hold secondary Ready to become secondary Chassis cluster LED information: Current LED color: Green Last LED change reason: No failures node1: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: secondary, Weight: 255 Time From To Reason Mar 27 17:44:27 hold secondary Hold timer expired Redundancy Group 1 , Current State: secondary, Weight: 255 Time From To Reason Mar 27 17:44:27 hold secondary Hold timer expired Mar 27 17:50:23 secondary primary Remote yield (100/0) Mar 27 17:50:24 primary secondary-hold Preempt/yield(100/200) Mar 27 17:50:25 secondary-hold secondary Ready to become secondary Redundancy Group 2 , Current State: primary, Weight: 255 Time From To Reason Mar 27 17:44:27 hold secondary Hold timer expired Mar 27 17:50:23 secondary primary Remote yield (200/0) Chassis cluster LED information: Current LED color: Green Last LED change reason: No failures
샘플 출력
섀시 클러스터 정보 표시(비정상적인 경우 모니터링)
user@host> show chassis cluster information
다음 출력은 비정상적인(비정상) 사례를 모니터링하는 데 특정합니다.
node0: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: secondary, Weight: 255 Time From To Reason Apr 1 11:07:38 hold secondary Hold timer expired Apr 1 11:07:41 secondary primary Only node present Apr 1 11:29:20 primary secondary-hold Manual failover Apr 1 11:34:20 secondary-hold secondary Ready to become secondary Redundancy Group 1 , Current State: primary, Weight: 0 Time From To Reason Apr 1 11:07:38 hold secondary Hold timer expired Apr 1 11:07:41 secondary primary Only node present Redundancy Group 2 , Current State: primary, Weight: 255 Time From To Reason Apr 1 11:07:38 hold secondary Hold timer expired Apr 1 11:07:41 secondary primary Only node present Chassis cluster LED information: Current LED color: Amber Last LED change reason: Monitored objects are down Failure Information: IP Monitoring Failure Information: Redundancy Group 1, Monitoring Status: Failed IP Address Status Reason 10.1.1.1 Unreachable redundancy-group state unknown node1: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: primary, Weight: 255 Time From To Reason Apr 1 11:08:40 hold secondary Hold timer expired Apr 1 11:29:20 secondary primary Remote is in secondary hold Redundancy Group 1 , Current State: secondary, Weight: 0 Time From To Reason Apr 1 11:08:40 hold secondary Hold timer expired Redundancy Group 2 , Current State: secondary, Weight: 255 Time From To Reason Apr 1 11:08:40 hold secondary Hold timer expired Chassis cluster LED information: Current LED color: Amber Last LED change reason: Monitored objects are down Failure Information: IP Monitoring Failure Information: Redundancy Group 1, Monitoring Status: Failed IP Address Status Reason 10.1.1.1 Unreachable redundancy-group state unknown
샘플 출력
섀시 클러스터 정보 표시(Preempt Delay Timer)
user@host> show chassis cluster information node0: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: secondary, Weight: 255 Time From To Reason Aug 4 12:30:02 hold secondary Hold timer expired Aug 4 12:30:05 secondary primary Only node present Aug 4 14:19:58 primary secondary-hold Manual failover Aug 4 14:24:58 secondary-hold secondary Ready to become secondary Redundancy Group 1 , Current State: secondary, Weight: 255 Time From To Reason Aug 4 14:07:57 secondary primary Remote is in secondary hold Aug 4 14:20:23 primary secondary-hold Monitor failed: IF Aug 4 14:20:24 secondary-hold secondary Ready to become secondary Aug 4 14:20:54 secondary primary Remote is in secondary hold Aug 4 14:21:30 primary secondary-hold Monitor failed: IF Aug 4 14:21:31 secondary-hold secondary Ready to become secondary Chassis cluster LED information: Current LED color: Green Last LED change reason: No failures node1: -------------------------------------------------------------------------- Redundancy Group Information: Redundancy Group 0 , Current State: primary, Weight: 255 Time From To Reason Aug 4 12:33:47 hold secondary Hold timer expired Aug 4 14:19:57 secondary primary Remote is in secondary hold Redundancy Group 1 , Current State: primary, Weight: 255 Time From To Reason Aug 4 14:07:56 secondary-hold secondary Ready to become secondary Aug 4 14:20:22 secondary primary Remote is in secondary hold Aug 4 14:20:37 primary primary-preempt-hold Preempt (99/101) Aug 4 14:20:52 primary-preempt-hold secondary-hold Primary preempt hold timer e Aug 4 14:20:53 secondary-hold secondary Ready to become secondary Aug 4 14:21:28 secondary primary Remote yield (99/0) Chassis cluster LED information: Current LED color: Green Last LED change reason: No failures
릴리스 정보
Junos OS 릴리스 12.1X47-D10에 명령어 도입.